Product Introduction
Product type, manufacturing date (calendar week/year of construction) and if
required, conformity mark can be found on the nameplate on the product.
Please provide us with the contents of the nameplate when making enquiries
about the product.
SAFETY REGULATIONS AND INFORMATION
Read the operating manual carefully before commencing work at the product. Pay
attention to the following warnings to avoid risk to persons or
malfunctioning.
This operating manual is an integral part of the product.
In the event of resale or change of ownership the operating manual must
accompany the product. This operating manual may be copied and provided as
information on potential risks and their avoidance.
Hazard classification of warning notices
The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions:
DANGER
This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed. Observe this warning.
WARNING
The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed. Work with extreme care.
CAUTION
The dangerous situation can occur and can result in minor injuries or damage to property if the warning is not observed.
NOTE
A potentially dangerous situation can occur and results in damage to property if not avoided.
Qualification of personnel
Only skilled electricians are permitted to install the product, to carry out
the test run and to work at the electrical unit.
Only instructed and authorized skilled personnel are permitted to transport,
unpack, operate and service the product.
Basic safety regulations
Safety risks related to the product must be reassessed after installing in the
final device.
The operating manual was developed in accordance with European market
requirements and may need adapting to the market requirements of the country
in question.
When working at the product, observe the following:
- Do not make any changes to the product.
WARNING
Impermissible high load
- Stop the product immediately after impermissible loading (e.g. impact, heat, overvoltage)
Electrical voltage and current
DANGER Electrical voltage
Regularly check the electrical equipment of the product.
- Eliminate immediately loose connections and defective cables.
CAUTION
In the event of a fault, the product is energized.
Product has basic insulation.
- Do not touch the product after installing.
Safety and protective functions
DANGER
Missing safety device and faulty protective equipment.
Without protective equipment severe injuries can occur, e.g. by taking hold of the rotating equipment.
- Operate the product with protection guards only.
Electromagnetic radiation
Electromagnetic compatibility (EMC) may affect the system integration of the product due to interaction.
- Ensure the electromagnetic compatibility of the entire system.
Moving parts
DANGER
Self-starting product
If voltage is applied, the motor automatically restarts after a mains failure or when blocking has been eliminated.
- Do not stand in the danger zone of the product.
- Switch off the mains voltage when working on the product and secure against switching on again.
DANGER
Rotating impeller
Contact with the impeller may result in injuries. Long hair, loose-fitting garments and jewellery can be caught and pulled into the product. Risk of injury.
- Before starting the product, ensure that it is securely fixed and that the guards are in place.
- Do not wear loose-fitting garments or jewellery when working on moving parts.
- Protect long hair by wearing a hair net.
CAUTION
High risk of fire spreading Can cause fire to spread.
- Never direct the airflow (intake/exhaust side) at a potential source of fire.
CAUTION
High temperature at motor housing.
Risk of burns
- Provide adequate protection against accidental contact.
Transport
Only transport the product in its original packaging. Secure during transport.
The vibration values, temperature and climate ranges should not be exceeded
during transport.
Storage
- Store the device, partially or fully assembled, in a dry place, protected against the weather and free from vibration, in the original packaging in a clean environment.
- Protect the device against environmental effects and dirt until final installation.
- To guarantee trouble-free operation and the longest possible service life do not store the device for more than one year.
- Even devices explicitly intended for outdoor use are to be stored as described prior to commissioning.
- Maintain the storage temperature, see Chapter 3, Technical Data
Cleaning
NOTE
Product damaged during cleaning
- Clean the product carefully with a moist cloth without applying pressure to the rotor. Do not use cleaning agents that contain acids, caustic solutions or solvents.
Disposal
When disposing of the product, observe all requirements and regulations that are relevant in your country.
INTENDED USE
The product is designed exclusively as a built-in device for conveying air
according to the technical data.
Every use that is not in accordance with the intended purpose, is regarded as
misuse of the product.
On-site installations must comply with the mechanical, thermal and service
life requirements, see Chapter 3, Technical Data.
Intended use includes:
- Operating the product with all protective equipment
- Do not put the product into operation before it has been installed in the customer’s application
- Observation of the operating manual
Use for other than the intended purpose
Using the product for the purposes mentioned below is prohibited and can be dangerous:
- Conveyance of air that contains abrasive particles.
- Conveyance of air that has a highly corrosive effect.
- Conveyance of air that has a high dust load, e.g. vacuuming sawdust.
- Conveyance of inflammable gases/particles.
- Contact with materials that can damage the product, e.g. acids, caustic solutions, solvents.
- Exposure to radiation that can damage product components, e.g. strong UV rays or thermal radiation.
- Operating during external vibration.
- Operating the product close to inflammable materials or components.
- Operating the product in an explosive atmosphere
- Use of the product as a safety component or for performing safety relevant functions.
- Operating in medical devices with life-sustaining or life-saving function if not validated together with ebm-papst.
- Operating in non-stationary systems, e.g. railway vehicles, aircraft and spacecraft if not validated together with ebm-papst.
- Operating with fully or partially dismantled or manipulated protective equipment.
- Operating the product under conditions other than those mentioned in the technical data.
- Furthermore, all fields of application not mentioned under intended use.
An in situ assessment must be conducted of the heating behavior (appropriate and inappropriate operation), the protection against contact, electrical shocks, impact of foreign objects or water and the usage at altitudes higher than 2000 meters.
Contact ebm-papst if you have specific queries regarding the product.
TECHNICAL DATA
Drawing, see annex
Technical description
Airflow direction | Air outlet over struts |
---|---|
Rotating direction looking at rotor. | Clockwise |
Frequency | 50 Hz / 60 Hz |
Nominal voltage | 100 V – 240 V |
Current consumption | 68 mA |
Power consumption | 4,4 W |
Speed | 3.300 1/min |
Max. free-air flow | 172 m3/h |
Mass | 0,235 kg |
Protection class | built-in fan |
Max. torque when mounted across both mounting flanges | Wire outlet corner: 50 |
Ncm Remaining corners: 80 Ncm
Screw size| ISO 4762 – M4 degreased, without an additional brace and without
washer.
The product is for the use in sheltered rooms with limited controlled
temperature. Occasionally condensed water is allowed. Direct exposure to water
must be avoided. Saline ambient conditions must be avoided.
Pollution degree 2 (according DIN EN 60664-1) It occurs only non-conductive
pollution. Occassionally, temporary conductivity caused by condensation
occurs.
Ambient conditions
Permitted ambient temperature
Transport and storage| Operation
-40 °C … 80 °C| -40 °C … 70 °C
Vibration and shock load
The mechanical Vibration and Shock data for the product is available.
If the operation of the product should take place in a sinusoidal vibration
containing environment or fixing the product on sinusoidal vibrating surface,
please contact our technical support.
Do not operate your product in the resonance range.
CONNECTION AND COMMISSIONING
Connect mechanical parts
CAUTION
Risk of cutting/squashing when removing the product from the packaging and
during mounting.
Grasp the housing and lift the product carefully out of the packaging. Avoid
impact.
- Wear safety boots and cut-resistant gloves.
NOTE
Risk of damage to electronic components.
- Use ESD protective equipment when mounting.
Connect electrical parts
Connect to the mains after installation.
DANGER
Do not touch. Risk of fatal injury from electrical current.
- Ensure that the electrical lines are de-energized.
- Secure the operating voltage against switching on again.
- Never work on parts that are energized. Only allow skilled electricians to work on the product.
DANGER
Compliance with the electrical installation regulations
- Observe the connection regulations that are valid in your country. (e.g. fusing, GFCI)
CAUTION
Electrical voltage
The product is a built-in component and has no switch for disconnecting power.
- Only connect the product to current circuits that can be switched off by a switch (all poles disconnected). When working on the product, secure the system/machine in which the product is installed against switching on again.
NOTE
Electromagnetic compatibility (EMC) may affect the system integration of the product due to interaction.
- Ensure the electromagnetic compatibility of the entire system.
Ground fault interrupter GFI
DANGER
Electrical voltage
- As additional protection we recommend the installation of a RCD (residual current protective device), which is adequate for product, usage and application.
- If it is possible to touch the fan directly / indirectly, the installation must be protected by a grounding contact and the supply voltage of the fan by a residual current device (RCD / FI).
Voltage control
Speed control via the supply voltage is not possible. Speed control via PWM of the supply voltage is not permitted.
Requirements:
- Before connecting the product, ensure that the supply voltage corresponds with the product voltage.
- Check whether the data on the nameplate corresponds with the interface data.
Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions. Ensure that the electrical interface data is adequately protected (mechanical).
Find additional information in drawing or label.
Check connections
NOTE
ACmaxx- and ACi-fans are built-in products and must not be earthed.
Connect product
Check the product for visible damage and the operability of protective
equipment before switching on.
If damage is visible, do not start the product.
FAULTS, POSSIBLE CAUSES AND REMEDIES
Replace your product by a new one, do not repair it.
DANGER
Electrical voltage at motor
- Wait five minutes after the voltage (all poles) has been switched off before opening the product.
Fault/ Error | Possible cause | Possible remedial action |
---|---|---|
Motor is not rotating | Mechanical blocking | Switch off, de-energize and |
eliminate mechanical blocking.
Mains voltage fault| Check mains voltage, re-connect voltage supply.
Connection faulty| Rectify connection, see pin connection.
Motor is too hot| Allow motor to cool / identify cause of fault.
Motor winding interrupted| Exchange product.
Ambient temperature too high| Reduce ambient temperature if possible.
Impeller out of true| Unbalance of rotating parts| Clean product if still
unbalanced after cleaning, exchange product.
Note
If the device is not operated for a lengthy period in installed condition in a
dry environment, it is to be started up and operated at full speed for one
hour at least every four months. If the device is not operated for a lengthy
period in installed condition in a damp environment (e.g. outdoors), it is to
be started up and operated at full speed for at least three hours once a month
to move the bearings and allow any condensate that may have ingressed to
evaporate.
In case of further faults, contact ebmpapst.
Technical safety inspection
What requires checking? | How to check? | Frequency |
---|---|---|
Protection against accidental contact/ protective clothing | Visual inspection |
min. 1/2 yearly
Check product for damage| Visual inspection| min. 1/2 yearly
Fixation of product| Visual inspection| min. 1/2 yearly
Fixation of wires| Visual inspection| min. 1/2 yearly
Insulation of wires| Visual inspection| min. 1/2 yearly
Check impeller for wear/sediments/ corrosion| Visual inspection| min. 1/2
yearly
COMPLIANCE
Customer Support
ebm-papst St.Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D – 78112 St.Georgen
Phone : +49 (0) 7724 / 81-0
Fax : +49 (0) 7724 / 81-1309
info2@de.ebmpapst.com
www.ebmpapst.com
As per: 02.02.2022
Version: 1 5
Article number: 8315100206
1800671500
www.airefrig.com.au
References
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>