SKC 224-G5 Sorbent Tube Instruction Manual

June 13, 2024
SKC

SKC-logo

SKC 224-G5 Sorbent Tube

SKC-224-G5-Sorbent-Tube-product-image

Product Information

The Sorbent Tube is a specialized device used for sampling and analyzing air contaminants in occupational hygiene and environmental applications. It is available in three different sizes: 6 x 70mm, 6 x 110mm, and 8 x 110mm. The tube has specific flow rate specifications depending on its size, with maximum flow rates ranging from 500 ml/min to 1000 ml/min. The typical flow rates for the tube range from 10-100 ml/min to 20-200 ml/min.

Preparation:

  1. When preparing the tube for use, ensure that the ends are broken with a minimum hole diameter of 2mm or half the diameter of the tube body.
  2. Avoid calibrating or fitting tubes in areas where chemicals may be present to prevent uptake of spurious chemicals.
  3. After breaking the ends and fitting the tube into the tube holder, always cap the exposed (sampling) end until ready to take the sample. Note that the red end cap should be lightly pressed onto the tube for temporary use.
  4. Ensure clothing is free from contamination when handling the tubes to avoid pre-sample uptake.
  5. If unsure about the suitability of a tube for a specific analyte, seek advice before sampling as some tubes are specially treated for specific analytes.

Sampling:

  1. Always use the tube in a vertical position for occupational hygiene and environmental applications to prevent under sampling caused by channelling.
  2. The arrow printed on the glass tube indicates the air flow direction, which should point towards the tube holder. If no arrow is present, ensure that the smallest sorbent section is nearest the tube holder.
  3. After sampling, immediately cap both ends of the tube with the supplied red plastic caps and press them fully home to ensure a good seal.
  4. Analyze the tubes at the earliest opportunity after the sample has been taken.
  5. Tubes can be used in series if needed.
  6. If high moisture is present, use a trap tube before the sorbent tube.
  7. Note that high temperature and moisture can affect adsorption characteristics.

Storage:

  1. Avoid storing used tubes in areas where chemicals may be present, especially chemicals of the same type or family that have been sampled for. This also applies when the end caps are in place on a used tube.
  2. Always store a “blank” tube in the same way when storing used tubes. Analyze the blank first to confirm no contamination has occurred during storage. A “blank” tube refers to a tube with ends broken off but capped.
  3. When sending tubes through the post to a laboratory, it is recommended to enclose them in a clean plastic bottle. Always include one unbroken tube from the same batch and a tube with both ends broken off, capped but not exposed as a sample.

Analysis:

  1. Analyze the tubes at the earliest opportunity, if possible.
  2. When analyzing on a GCMS (Gas Chromatography-Mass Spectrometry), only use tubes with glass wool separators. Adhere to all handling procedures tightly and use blanks for accurate analysis.
  3. Tubes normally have two sections. When analyzing, test both sections independently. The NIOSH-Approved Sealing Caps prevent contamination, and the Precision Lockspring holds sorbent layers securely in place to prevent sample channeling.

Sorbent Tube

Operating Instructions

FLOW RATES

Tube Size Maximum Flow Rate Typical Flow Rate
6 x 70mm 500 ml/min 10-100 ml/min
6 x 110mm 500 ml/min 20-100 ml/mn
8 x 110mm 1000 ml/min 20-200 ml/min

PREPARATION

  1. When breaking the ends of a tube ready for use ensure a minimum hole diameter of 2mm or half the diameter of the tube body.
  2. Never calibrate or fit tubes ready for use in an area where chemicals may be present.
  3. Uptake of spurious chemicals can occur before a sample is taken if the above is not observed.
  4. After breaking ends of the tube to be used and fitting into tube holder always cap the exposed (sampling) end until ready to take the sample. NOTE: only lightly press red end cap onto tube for temporary use. If the caps are pushed fully home they will require cutting off.
  5. Make sure clothing is free from contamination when preparing tubes. A commonly overlooked cause of pre-sample uptake is a lab coat which has been contaminated on the front, sleeves and cuffs from previous operations.
  6. Some tubes are specially treated for specific analytes, while others are more general. If in doubt about suitability please ask for advice before sampling.

SAMPLING

  1. For occupational hygiene and environmental applications always use a tube in a vertical position. This prevents the possibility of channeling which can lead to under sampling.
  2. The arrow printed on the glass tube indicates the air flow direction and should point toward the tube holder. If no arrow is present the smallest sorbent section should be nearest the tube holder.
  3. After sampling, immediately cap both ends of tube with red plastic caps supplied. Press fully home to ensure good seal.
  4. Tubes should be analysed at the earliest opportunity after sample has been taken.
  5. Tubes can be used in series.
  6. If high moisture is present use a trap tube before sorbent tube.
  7. High temperature/moisture can affect adsorption characteristics.

STORAGE

  1. Never store used tubes in an area where there may be chemicals present, especially chemicals of the same type or family you have sampled for. This also applies when the end caps are in place on a used tube.
  2. If storing for more than a few hours place tubes in a refrigerator at 0°C. Exposed tubes can be left in this situation for up to 1 week. Longer storage times are possible but depends on the analyte sampled. Please call for advice.
  3. When storing always store a ‘blank’ in the same way. Analyse blank first to confirm no contamination has taken place during storage. A ‘blank’ is defined as a tube with ends broken off, but capped.
  4. When sending tubes through the post to a laboratory it is better to enclose them in a container such as a CLEAN plastic bottle. ALWAYS include one tube from the same batch unbroken and a tube with both ends broken off, capped but not exposed as a sample.

ANALYSIS

  1. Always analyse at the earliest opportunity if possible.
  2. When analysing on a GCMS use only tubes with glass wool separators. With GCMS analysis all handling procedures must be tightly adhered to and blanks are essential.
  3. Tubes normally have two sections. When analysing, test both sections independently. If the smaller (backup) section contains more than 25% of the amount of analyte that is present on the main section (larger) breakthrough has taken place and a result of greater than the sum of both sections is the only conclusion that can be taken. If the backup section has less than 25% of the main section the addition of the amounts on both sections gives a valid result in units e.g 10 microgramms.
  4. Make sure ALL the sorbent is removed from the tube using a charcoal pick if necessary. Some man made sorbents have a tendency to stick to the inside of the glass tube.