TASK LP36HR18NDBBK30 Lighted Power Strip Instruction Manual

May 15, 2024
TASK

TASK LP36HR18NDBBK30 Lighted Power Strip

TASK-LP36HR18NDBBK30-Lighted-Power-Strip-PRODUCT-IMAGE

Product Information

Specifications

  • Product Name: Lighted Power Strip DV Series
  • Installation Type: With Built-In Power Supply
  • Model: DV Series
  • Power Supply: 120V
  • Fixture Size: 12-1/2 or 18-1/2 inches

Product Usage Instructions

Installation for LPS WITH Built-In Power Supply

  1. Turn off power at the panel.
  2. Secure the LPS to the wall by screwing into wall studs or using provided anchors.
  3. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver.
  4. Ground all GREEN wires to PEM studs inside the back frame.
  5. When connecting multiple LPS fixtures, run Romex from fixture to fixture and ground each section.
  6. To terminate the last LPS, use wire nuts on the ends of wires
  7. Snap the cover in place and turn the power on.

Installation for LPS WITHOUT Built-In Power Supply

  1. Turn off power at the panel.
  2. Secure the LPS to the wall by screwing into wall studs or using provided anchors.
  3. Connect BLACK to BLACK and WHITE to WHITE. Ground all GREEN wires to PEM studs inside the back frame.
  4. When connecting two LPS fixtures, run Romex from fixture to fixture and ground each section.

Frequently Asked Questions (FAQ)

  1. Q: Can I connect multiple LPS fixtures together?
    A: Yes, you can connect multiple LPS fixtures by running Romex from fixture to fixture and grounding each section to the next.

  2. Q: Do I need to use wire nuts to terminate the last LPS?
    A: Yes, it is recommended to use wire nuts on the ends of wires when terminating the last LPS.

  3. Q: How do I know if the 120V receptacle circuit must be GFCI protected?
    A: The 120V receptacle circuit must be GFCI protected as indicated in the wiring diagrams for safety.

LIGHTED POWER STRIP
installation instructions
January 2019

Lighted Power Strip DV Series

Installation Instructions for LPS WITH Built-In Power Supply

General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS. TASK-LP36HR18NDBBK30-Lighted-Power-Strip-
\(2\)

Wiring for Combined Light and Receptacle Circuit – Non Dimmable

TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(3\)

  1. Step 1
    Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN wires to PEM studs inside of back frame.

  2. Step 2
    When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.

  3. Step 3
    To terminate last LPS, use wire nuts on ends of wires.
    Step 4
    Snap cover in place and turn power on.

Wiring for Separate Light and Receptacle Circuits

TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(4\)

  1. Step 1
    Secure LPS to wall by screwing into wall studs or use anchors provided. If running two circuits, one for receptacles, one for lighting, connect fixture wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

  2. Step 2
    When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.

  3. Step 3
    To terminate last LPS, use wire nuts on ends of wires.

  4. Step 4
    Snap cover in place and turn power on

Wiring Diagram for Combined Light & Receptacle Circuit – Non Dimmable

TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(5\)

Wiring Diagram for Separate Light & Receptacle Circuits

TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(6\)

General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(7\)

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

TASK-LP36HR18NDBBK30-Lighted-Power-Strip- \(8\)

Remote Power Supply- 120V Entry

  1. Step 1
    Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK to BLACK, WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

  2. Step 2
    When connecting two LPS, run Romex from fixture to fixture. Ground each section to the next.

  3. Step 3
    To terminate last LPS, use wire nuts on ends of wires
    Remote Power Supply-Low Voltage Entry

  4. Step 4
    Using appropriate knockout hole, pull low voltage wire from remote power supply into the low voltage space, connect BLACK wire (negative) to BLACK wire from lights and RED wire (positive) to RED wire.

  5. Step 5
    Snap cover in place and turn power on.

Customer Service: 800.445.6404
Design Services/Technical Support: 866.848.9094
TaskLighting.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals