TASK power LP42HR21NDGSN50 Lighted Power Strip DV Series Instruction Manual

May 15, 2024
TASK power

TASK power LP42HR21NDGSN50 Lighted Power Strip DV Series

TASK-power-LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series-
PRO

Product Information

Specifications:

  • Product Name: Lighted Power Strip DV Series
  • Installation Type: With Built-In Power Supply
  • Model: DV Series
  • Power Supply: 120V
  • Fixture Size: 12-1/2 or 18-1/2 inches

Product Usage Instructions

General Guidelines:
Before starting the installation process, make sure to turn off the power at the panel.

Installation Steps:

Step 1: Secure LPS to Wall
Secure the Lighted Power Strip to the wall by screwing it into wall studs or using the anchors provided.

Step 2: Wiring for Combined Light and Receptacle Circuit (Non-Dimmable):

  1. Connect BLACK Romex wire to BLACK wire from receptacles and switch.
  2. Connect WHITE Romex wire to WHITE wire from receptacles and driver.
  3. Ground all GREEN wires to PEM studs inside the back frame.

Step 3: Connecting Multiple LPS Fixtures:
If connecting multiple fixtures, run Romex from fixture to fixture and ground each section to the next.

Step 4: Finalizing Installation:

  1. To terminate the last LPS, use wire nuts on the ends of wires.
  2. Snap the cover in place and turn the power back on.

Frequently Asked Questions (FAQ)

  • Q: What should I do if I encounter difficulties during installation?
    A: If you face any challenges during installation, please contact our Customer Service at 800-445-6404 or email DesignAndSupport@TaskLighting.com for assistance.

  • Q: Can I connect multiple Lighted Power Strip fixtures together?
    A: Yes, you can connect multiple fixtures by running Romex from fixture to fixture and ensuring proper grounding between sections.

DV Series

General Guidelines
  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

Wiring

Wiring for Combined Light and Receptacle Circuit – Non Dimmable:TASK-
power-LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series-
\(2\)

  1. Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN wires to PEM studs inside of back frame.
  2. When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
  3. To terminate last LPS, use wire nuts on ends of wires.
  4. Snap cover in place and turn power on.

Wiring for Separate Light and Receptacle Circuits:TASK-power-
LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series- \(3\)

  1. Secure LPS to wall by screwing into wall studs or use anchors provided. If running two circuits, one for receptacles, one for lighting, connect fixture wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.
  2. When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
  3. To terminate last LPS, use wire nuts on ends of wires.
  4. Snap cover in place and turn power on.

Wiring Diagram for Combined Light & Receptacle Circuit – Non Dimmable :TASK-power-LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series-
\(4\)

Wiring Diagram for Separate Light & Receptacle Circuits:TASK-power-
LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series- \(5\)

RM Series

General Guidelines
  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.TASK-power-LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series-
\(6\)

Remote Power Supply

TASK-power-LP42HR21NDGSN50-Lighted-Power-Strip-DV-Series-
\(7\)

  1. Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK to BLACK, WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.
  2. When connecting two LPS, run Romex from fixture to fixture. Ground each section to the next.
  3. To terminate last LPS, use wire nuts on ends of wires.
  4. Using appropriate knockout hole, pull low voltage wire from remote power supply into the low-voltage space, connect BLACK wire (negative) to BLACK wire from lights and RED wire (positive) to RED wire.
  5. Snap cover in place and turn power on.

Customer Service: 800.445.6404
Design Services/Technical Support: 866.848.9094
TaskLighting.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>