Alphalite RWUX-2408A-WH Slim Round LED High Bay Instruction Manual

May 15, 2024
Alphalite

Alphalite RWUX-2408A-WH Slim Round LED High Bay

Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-
PRODCUT

Specifications

  • Model: RWUX-(150/100/75)/8A, RWUX-(240/200/150)/8A
  • IP Rating : LED IP Rated High Bay
  • Manufacturer: Not provided
  • Contact : 11920 Altamar Place, Santa Fe Springs, CA 90670
  • Telephone: 1-888-287-9228
  • Email: support@alphalite.com

Installation Instructions

LED IP Rated High Bay
Installation guide valid for the following models:

  • RWUX-(150/100/75)/8A
  • RWUX-(240/200/150)/8A

WARNING
RISK OF FIRE OR ELECTRIC SHOCK
The LED IP-rated High Bay must be installed by a qualified electrician by applicable federal, state, and local laws and codes. Installation requires knowledge of luminaire electrical systems and the installer should be familiar with the operation of this product. If not qualified, do not attempt installation; contact a qualified electrician. The manufacturer assumes no responsibility for the improper installation of this luminaire. When installing the fixture, drilling may damage luminaire wiring and electrical parts. Check for wiring and components in the enclosure before drilling. To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects. When installing this kit, drilling may damage luminaire wiring and electrical parts. Check for wiring and components in the enclosure before drilling.

CAUTION: RISK OF PERSONAL INJURY

  • Wear gloves or proper handling protection to prevent cuts or abrasions when handling and maintaining this product. This equipment may have sharp edges. To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Avoid direct eye exposure to the light source while it is on.

WARNING
RISK OF PERSONAL INJURY, FIRE, OR ELECTRIC SHOCK Turn OFF power before installation.

NOTICE

  • Green ground screw provided in the proper location. Do not relocate.
  • Minimum 90° supply conductors.
  • Specifications and dimensions are subject to change without notice.
  • Suitable for Dry or Damp locations.

Contact the manufacturer with any questions or concerns regarding the installation of this luminaire.

LED IP Rated High Bay

A: Hanging Mount (Hook or Ring)
Standard equipped Hook, opional Ring RWUX-RMK

  1. Screw the hook or Ring into the fixture, tighten and fix it. (figure 1)
  2. Hang the fixture on the ceiling hook or chain. (figure 2)
  3. Loop the safety cable around a structural member of the building providing a secondary support for the mounted fixture. (figure 13)
  4. Connect the wires of the fixture to the mains according to local wiring rules, ensure the connection is stable and make good protection on the connection.Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-1

B: Surface Mount

Item No. RWUX-SMK

  1. Make a mark and drill the mounting surface and fix the screws (figure 3)
  2. Install the RWUX-SMK on the fixture (figure 4)
  3. Align the bracket holes with the screws, and push thefixture to one side and fix it. (figure 5)
  4. Loop the safety cable around the structural member (figure13)
  5. Connect the wires according to local wiring rules,ensure the connection is stable, and good protection on the connection.
  6. the RWUX-SMK supports adjust 50° to the left or right vertically by loosening and tightening the screws.

Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-2

C: Pendant mount (for 1/2’’ stem)
(The power cable passes through the inside of the stem)

Item No. RWUX-SMK

  1. Unscrew the nuts on 1/2” stem (not provided) and insert it into the hole of RWUX-SMK (figure 6)
  2. Re-screw the nut and loop the safety cable around a structural member of the building providing a secondary support for the mounted fixture.
  3. Connect the wires of the fixture to the mains according to local wiring rules, ensure the connection is stable, and make good protection on the connection (figure 10)
  4. the RWUX-SMK supports adjust 50° to the left or right vertically by loosening and tightening the screws.

Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-3

D: Pendant mount (for 1/2’’ stem and 3/4” stem)
(Power cable doesn’t pass thru the inside of the stem, or with a hole on the side for cable, stems provided by others

Opional RWUX-PMK3/4

  1. Twist the 1/2” stem it into the hole of the fixture. (figure 7)
  2. Twist the RWUX-PMK3/4 into the hole of the fixture, and then twist the 3/4” stem into the RWUX-PMK3/4. (figure 8)
  3. Loop the safety cable around a structural member (figure 13)
  4. Connect the wires of the fixture to the mains according to local wiring rules, ensure the connection is stable, and make good protection on the connection

Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-4

LED IP Rated High Bay

Accessory Installation (options)

  1. PIR / Microwave sensor (MMS-DC-PIR4T, MMS-DC4T)
  2. Removed the 1/2” stopper from the fixture. (figure 9)
  3. Twist-lock the DC sensor to the base (figure 10)
  4. Be sure the sensor is tightened before use, setting the data according to the pec sheet of the sensor and remote control RC-100.Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-5
  5. Reflector Cone (RWUX-RPC, RWUX-RAL)
  6. Lock the PC or Aluminum reflector to the fixture (figure 11)Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-6
  7. Wire Guard (RWUX-WG)
  8. Put the wire guard on the fixture and fix it. (figure 12)
  9. Install safety cable
  10. Loop the safety cable around a structural member of the building (figure 13
  11. Emergency (EM-RM40W-GW)
  12. Install the EM according to EM spec sheet. (figure 14)Alphalite-RWUX-2408A-WH-Slim-Round-LED-High-Bay-FIG-9
  13. Wattage and CCT field adjust
  14. Remove the stopper, pull the DIP switches to adjust the wattage and CCT, and then insert the stopper. (figure 15

FAQ

Frequently Asked Questions

  • Q: Can I install this fixture myself?
    • A: Installation of the LED IP Rated High Bay must be done by a qualified electrician to prevent risks of fire, electric shock, or personal injury. If not qualified, contact a professional electrician.
  • Q: How should I handle and maintain this product?
    • A: Wear gloves or proper handling protection to prevent cuts or abrasions when handling the product. Avoid direct eye exposure to the light source while it is on to protect your eyes.
  • Q: What should I do if I have questions about installation?
    • A: Contact the manufacturer at the provided contact information for any questions or concerns regarding the installation of this luminaire.

CONTACT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals