onyx PR3268.2.01.24 Fusion LCD Electric Fire Instruction Manual

May 15, 2024
ONYX

Fusion Electric
LCD ELECTRIC FIRE
with Thermostatic Remote Controlonyx PR3268.2.01.24 Fusion LCD Electric
Fire - fig

INSTRUCTIONS FOR SERVICING
For use in
Great Britain & Republic of Ireland
CONSUMER SUPPORT VIDEO: www.onyxfires.com/support/fusion FUSION 150RW
228-275

PAIRING THE REMOTE CONTROL TO THE APPLIANCE

Signal Code
The below operations should be carried out before coding when changing to a new remote or the unit cannot be controlled by the remote:
Press the power button for until 2 short beeps sound from the unit, release the button.onyx PR3268.2.01.24 Fusion LCD Electric Fire - power
buttonWithin 10 seconds, press the button on remote. The coding is finished when 1 long beep sounds from the unit.
Resetting of the remote control is necessary if the appliance operates wrongly due to external interference signal and the remote control is not in use.
Open the back cover of the Remote.
Press the Reset button for 3 seconds and reset the coding.

ACCESSING THE FUEL BED

onyx PR3268.2.01.24 Fusion LCD Electric Fire -
ACCESSING

LOG SET – LOG LAYOUT

onyx PR3268.2.01.24 Fusion LCD Electric Fire - LOG
LAYOUTonyx PR3268.2.01.24 Fusion LCD
Electric Fire - LOG LAYOUT 1onyx
PR3268.2.01.24 Fusion LCD Electric Fire - LOG LAYOUT 2onyx PR3268.2.01.24 Fusion LCD Electric Fire - LOG LAYOUT
3

REMOVING THE FUEL BED

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE FUEL
BED REMOVING THE FUELBED EFFECT SPINDLE

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE FUELBED EFFECT
SPINDLE

REPLACING THE FUEL BED LEDS

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REPLACING THE FUEL BED
LEDS'

REMOVING THE DOWNLIGHT

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE
DOWNLIGHT

REMOVING THE GLASS SIDE PANELS

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE GLASS SIDE
PANELS REMOVING THE INNER SCREEN

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE INNER
SCREEN LCD SCREEN – 1 & 2

onyx PR3268.2.01.24 Fusion LCD Electric Fire - LCD
SCREEN

REMOVING THE RECEIVER

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REMOVING THE
RECEIVER REPLACING THE CONTROL UNIT 1

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REPLACING THE CONTROL
UNIT

  1. PCB
  2. POWER SWITCH
  3. BUTTON BOARD

PCB

onyx PR3268.2.01.24 Fusion LCD Electric Fire - PCB POWER SWITCH

BUTTON BOARD

onyx PR3268.2.01.24 Fusion LCD Electric Fire - BUTTON
BOARD REPLACING THE CONTROL UNIT 2

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REPLACING THE CONTROL UNIT
2

REPLACING THE HEATER

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REPLACING THE
HEATER

REPLACING THE POWER UNIT

onyx PR3268.2.01.24 Fusion LCD Electric Fire - REPLACING THE POWER
UNIT

SPARE PARTS LIST

onyx PR3268.2.01.24 Fusion LCD Electric Fire - SPARE PARTS
LIST

| FUSION 150RW
---|---
CODE| QTY
la| EL1126| 2
lb| EL1127| 1
2| EL0938| 1
3| EL1129| 1
4| EL1128| 1
5| EL1125| 1
6| EL1123| 1
7| EL0936| 1
8| EL0905| 1
9| EL1136| 1
10| EL0726| 2
11| EL0727| 3
12| EL0724| 1
13a| EL0714| 1
13b| EL0933| 1
14| EL1121| 2
15| EL1122| 1
16| EL0930| 2
17| EL1138| 1
18| EL1137| 4
19| EL1132| 2
20| EL1131| 2
21| EL1134| 1
22| EL0973| 1
23| EL1133| 1
24| EL1135| 1
25| EL1124| 1
26| EL1130| 5

WIRING DIAGRAM

onyx PR3268.2.01.24 Fusion LCD Electric Fire - WIRING
DIAGRAM COLOUR CODES

  • RED
  • BLUE
  • YELLOW
  • WHITE
  • BLACK
  • BROWN
  • GREEN & YELLOW
1 Top Light LED Board
2 Heater Unit
3 Fan Motor
4 Heater
5 Thermostat
6 Flame Effect Motor
7 Button Board
8 Receiver Board
9 PCB
10 Flame Effect LED Board
11 Fuel Effect LED Board
12 Plug Connector Incoming

AC Supply: 230V 50Hz required
13| UK BS1363 Plug
13A BS1362 Fuse
14| LCD

PRODUCT MATERIAL INFORMATION

When the waste bin symbol with a cross is found on a product, it means that this product is subject to the European Directive 2012/19 / EU (implemented by the national legislation with the legislative decree of March 14, 2014, n.49).
In accordance with European Directive 2012/19/ EU, waste electrical and electronic equipment (WEEE) must not be disposed of with household or unsorted municipal waste.
At the end of its useful life please take this product to an appropriate recycling centre, collection point or utilise a distributor take-back service.
Failure to do so may result in negative effects on the environment and/or human health as a result of the possible presence of hazardous substances in electrical and electronic equipment and of the mishandling of such equipment.
You can find your nearest recycling centre by contacting your local authority, for UK customers using the bank locator at www.recycle-more.co.uk or for customers in the Republic of Ireland at www.weeeireland.ie.
Take-back services can be discussed with your authorised dealer.

FOR ENQUIRIES IN THE U.K (EXCLUDING NI):
Gazco Limited, Spitfire Avenue, Skypark, Clyst Honiton, Exeter, Devon, England EX5 2FR
Tel: (01392) 261900 E-mail: [email protected]
FOR ENQUIRIES IN EUROPE (INCLUDING NI):
Stovax Heating Group (NI) Ltd (Comp reg NI675194), 40 Linenhall Street, Belfast, BT2 8BA
DX 400 NR Belfast Tel: +44 (0)1392 261990 E-mail: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ONYX User Manuals

Related Manuals