ZEVNI A04761C6 Rudolf 6-Light Gold-Black Modern-Contemporary Chandelier Installation Guide
- June 8, 2024
- ZEVNI
Table of Contents
A04761C6 Rudolf 6-Light Gold-Black
Modern-Contemporary Chandelier
Installation Guide
A04761C6 Rudolf 6-Light Gold-Black Modern-Contemporary Chandelier
Item Number: A04761C6
WARNING (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position. -
Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides.
Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. -
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
TOOLS REQUIRED (NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING:
(C) Round mounting plate (1)
(D) Green ground screw (1)
(E) Canopy (1)
(F) Loop (4)
(G) Knob nut (2)
(H) Quick link (2)
(I) Stem
(J) Glass shade (6)
(K) Socket (6)
(L) Fixture body (1)
ACCESSORIES & QTY ENCLOSED:
(A) Plastic wire connector (3)
(B) Mounting screw (2)
ASSEMBLY & INSTALLATION INSTRUCTIONS:
- Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
- Make preinstallation
Step A1 »
Choose the needed stems (I), and pass fixture wires through the chosen stems
(I), then screw stems (I) together onto the top of fixture body (L).
Step A2 »
Attach quick links (H) to loops (F) on canopy (E) and the top of stems (I).
Carefully pass the fixture wires through loops (F) and canopy (E). Gently pull
the wires to ensure the wires are not stressed.
3. Turn off power
Before you start the installation, NEVER attempt any work without shutting off
the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
4. Make installation
Step B1 » Unscrew knob nuts (G) from mounting plate (C).
Step B2 » Attach mounting plate (C) to the outlet box with mounting screws
(B).
Step B3 » If needed, shorten the fixture wires length. At this point, the
remaining wire length measured above mounting plate (C) is at least 6″.
Step B4 » Make wire connections.
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS
BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the below chart
Connect wires according to the below chart
Connect Black or Red Supply Wire to: | Connect White Supply Wire to: |
---|---|
Black | White |
*Parallel cord ( round & smooth) | *Parallel cord ( square & ridged ) |
Clear,Brown,Gold or Black without tracer | Clear,Brown,Gold or Black with |
tracer
Insulated wire ( other than green) with copper conductor| Insulated wire (
other than green ) with silver conductor
*Note: When parallel wires ( SPT I & SPT II ) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
Twist wires together with plastic wire connectors until tightly joined, and
wrap each connector with approved electrical tape. Be sure that no wire
strands are exposed and then carefully tuck all wires into the outlet box.
Step B5 » Raise canopy (E) to the ceiling and secure canopy (E) in place by
tightening knob nuts (G) onto preassembled screws on mounting plate (C).
NOTE: canopy (E) should be snug against the ceiling with knob nuts (G).
If not, remove canopy (E), adjust the threaded length of preassembled
mounting screws on mounting plate assembly (C):
- First, unscrew the preassembled hex nuts.
- Then, screw the preassembled mounting screws in or out of mounting plate (C).
- When the secure length is achieved, tighten the preassembled hex nuts and back to Step B5.
Step B6 » 1) Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the 2) Carefully screw glass shades (J) onto sockets (K). socket.)
5. Check everything is already installed properly, then you could turn on the light. Enjoy!
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to useexact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner
(such as mild and nonabrasive soap). Do not use abrasive materials such as
scouring pads or powders, steel wool or abrasive paper.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>