Specifications

  • Max. weight: 500g
  • Min. weight: 1g
  • Scale division: 0.1 g
  • Units of measurement: g, ct, gn, oz, ozt, dwt
  • Power supply: 2x CR 2032

Thank you for choosing a Xavax product.
Take your time and read the following instructions and information completely. Keep these operating instructions in a safe place for future reference.

Explanation of Warning Symbols and Notes

Warning: This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.

Package Contents

  • Digital precision scales
  • 2 CR2032 batteries
  • These operating instructions

Controls and Displays

  1. Unit button: Select the units of measurement
  2. Switch display backlight on/off
  3. Display
  4. TARE button: tare function
  5. Power on/off button
  6. Weighing surface

Safety Notes

  • This device is intended for private, non-commercial use only.
  • Protect the device from dirt, moisture, and overheating, and only use it in dry locations.
  • Do not drop the device and do not expose it to any major shocks.
  • Do not operate the device outside of its operating limits as defined in the technical specifications.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately according to locally applicable regulations.
  • Do not modify the device in any way. Doing so voids the warranty
  • Do not use the product near heaters or other heat sources or in direct sunlight.
  • Do not use the product in areas where the use of electronic devices is not permitted.
  •  Do not attempt to service or repair the product yourself. Leave all service work to qualified experts.
  • Keep this product, as all electrical products, out of the reach of children!
  • Use the item only in moderate climatic conditions.

Warning – batteries/button cells

  • When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly. Failure to do so could result in the batteries leakingor exploding.
  • Only use batteries that match the specified type. Keep the instructions for the correct choice of batteries included with the operating instructions of devices safe for future reference.
  • Before you insert the batteries, clean the battery contacts and the polarity contacts.
  • Do not allow children to change batteries without supervision.
  • Replace all the batteries in a set at the same time.
  • Do not mix old and new batteries or batteries of different types or from different manufacturers.
  • Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not burn batteries or heat them up.
  • Never open, damage, or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Remove spent batteries from the product and dispose of them without delay.
  • Avoid storing, charging, and using in extreme temperatures and at extremely low atmospheric pressures (such as at high altitudes).
  • Ensure that batteries with damaged housings do not come into contact with water.
  • Keep batteries out of the reach of children. Do not swallow batteries or button cells. Burning hazard from hazardous substances.
  • If the battery compartment will no longer close securely, stop using the product and keep it away from children.
  • This product contains button cells. If the button cell is swallowed, serious internal burns can occur within 2 hours and ultimately lead to death.
  • If you suspect that a button cell has been swallowed or is in any part of the body, seek medical attention immediately.
  • Keep new and used button cells out of the reach of children.

Getting Started

Insert the batteries:
Open the battery compartment on the back and insert two CR2032 button cell batteries. Make sure that the polarity (+/-) is correct. The positive pole (+) must point upwards. Close the battery compartment fully.

Units of measurement
The following units of measurement are available: g (gram), ct (carat), gn (grain), oz (ounce), ozt (troy ounce) and dwt (pennyweight). Press the Unit button to select one of the units of measurement in the given order: g-ct-gn- oz-ozt-dwt-g.

Weighing

  • Place the scales on a clean, level table. Make sure that the scales are stable and do not tilt.
  • Switch on the scales by pressing the Power on/off button. Initially, all symbols appear on the display. Please wait until ‘0.0 g’ appears. You can then place the item to be weighed onto the scales and read the weight value.

Using the tare function (TARE)
Place the empty container onto the scales; the weight is shown on the display. Set the scales to zero by pressing the TARE button. Now place the new item to be weighed (in the container) onto the scales. Only the net weight of the item (its weight without the weight of the container) is shown.

Once the display stops changing, the scales automatically switch off after approximately 60 seconds. You can manually switch off the scales by pressing and holding down the Power on/off button.

Error messages

  • When the error message ‘O-Ld’ is shown, the scale is overloaded.
  • When the error message ‘LO’ is shown, the battery is empty. Replace the battery as soon as possible.

Care and Maintenance

  • Only clean this product with a slightly damp, lint-free cloth, and do not use aggressive cleaning agents. Make sure that water does not get into the scales.
  • The weighing surface is made of stainless steel.

Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product, or failure to observe the operating instructions and/or safety notes.

Technical Data

The high-precision strain gauge sensor and the powerful processor ensure extremely precise weighing.

Distributed by Hama GmbH & Co KG 86652 Monheim / Germany www.xavax.eu

FAQ

Frequently Asked Questions

  • Q: How do I change the units of measurement?
    • A: Press the Unit button to cycle through the available units in the order: g-ct-gn-oz-ozt-dwt-g.
  • Q: How can I ensure accurate weighing results?
    • A: Make sure to place the item on a stable surface, allow the display to stabilize before reading, and calibrate using the TARE function when necessary.
  • Q: What should I do if the scales show a ‘Low battery ‘ warning?
    • A: Replace the battery with two CR2032 button cell batteries as soon as possible to ensure uninterrupted usage.

Service & Support

www.xavax.eu
+49 9091 502-0

All listed brands are trademarks of the corresponding companies. Errors and omissions excepted, and subject to technical changes. Our general terms of delivery and payment are applied.