geo-FENNEL FR 50 Rotating Lasers Receivers User Manual

May 15, 2024
geo-FENNEL

geo-FENNEL FR 50 Rotating Lasers Receivers

geo-FENNEL-FR-50-Rotating-Lasers-Receivers-PRODUCT

Specifications

  • Technical Data: Indication Accuracy Working range (radius)  accuracy
  • Signal tones
  • Power supply
  • Operating time – with activated LCD illumination
  • Temperature range
  • Magnets
  • Vials
  • Dust/water protection
  • Dimensions
  • Weight

Product Usage Instructions

Power Supply

  1. Power on/off the receiver by pressing the button.
  2. All displays will briefly light up once, then the unit automatically enters reception mode.

Selecting Accuracy Mode

Press the button to select the desired accuracy mode. The selected mode will be saved automatically.

Adjusting Volume

Press the button to set the volume level. A beep will sound to confirm the adjustment.

Switching On/Off Lighting

Press the button to toggle the lighting on or off.

Detecting the Laser Line

  • LED lights: Move the receiver down
  • LED lights: Move the receiver up

Safety Instructions

  • Handle measuring instruments with care.
  • Clean with a soft cloth only after use.
  • If necessary, dampen the cloth with water for cleaning.
  • If the instrument gets wet, clean and dry it carefully before storing it.
  • Transport in the original container/case only.

FAQ

Q: How do I know which accuracy mode is selected?

  • A: The selected accuracy mode will be indicated on the display of the instrument.

Q: Can I use the instrument in wet conditions?

  • A: It is recommended to avoid exposing the instrument to water or moisture to ensure proper functionality and longevity.

Dear customer,

  • Thank you for your confidence in us having purchased a geo-FENNEL instrument.
  • This manual will help you to operate the instrument appropriately.
  • Please read the manual carefully – particularly the safety instructions. Proper use only guarantees a long and reliable operation.
  • geo-FENNEL Precision by tradition.

SUPPLIED WITH

  • Receiver for rotating lasers FR 50
  • 2 x AA Alkaline batteries
  • Plastic clamp for leveling staff
  • User manual

properties

  • For rotating lasers with red or green laser beam
  • Length of the receiving window: 50 mm
  • Segments of the arrow in the display increase/decrease proportionally
  • Large LCDs at the front and back side
  • The backlight can be switched on/off – for optimal reading in all conditions
  • Sturdy housing – shockproof – and IP 67 dust/water protection
  • Long-range visible LED indication at front/side/back
  • Plastic clamp for leveling staff

Technical data

Indication Front and back display
Accuracy ± 1 / 2,5 / 5 mm
Working range (radius) / accuracy 300 m / ± 5 mm
  200 m / ± 2,5 mm
  100 m / ± 1 mm
Signal tones 2 (+ soundless)
Power supply 2 x AA Alkaline batteries
Operating time 56 h
– with activated LCD illumination 47 h
Temperature range -10°C to + 50°C
Magnets top, side
Vials top, side
Dust/water protection IP 67
Dimensions 175,5 x 78 x 31 mm
Weight 0,35 kg

FEATURES

  1. Vial (2)
  2. Receiving window
  3. Display
  4. Illumination on/off
  5. Sound on/off
  6. Accuracy selection
  7. Power ON/OFF
  8. LED indication/reference mark
  9. Magnets (2)
  10. Back LED
  11. Battery compartment
  12. Back display
  13. 0“ position
  14. Loudspeaker
  15. Thread for fixing the clampgeo-FENNEL-FR-50-Rotating-Lasers-Receivers-FIG-1

SYMBOLS

  1. Power ON/OFF
  2. Battery status indication
  3. Accuracy indication
  4. Sound on/off
  5. Receiving position laser beam

POWER SUPPLY

INSTALLATION OF THE BATTERIES

  • Open the battery compartment cover (11).
  • Insert 2 x AA Alkaline batteries according to the installation symbol (ensure correct polarity!). Close the cover.
  • To save battery power the receiver will automatically turn off if it has not received a laser scanning signal for 5 minutes.
  • When the battery symbol of the display starts flashing the batteries must be replaced.

OPERATION

Power on/off the receiver

  • Press the button to power on/off the receiver.
  • First, all displays light up once briefly (fig. 1).
  • Then the unit automatically enters the reception mode (fig. 2).

Select the receiving accuracy

  • Press the button to select the accuracy mode requested.
  • The mode selected will be saved automatically.
  • (fig. on the right)

Set the volume

  • Press the button to set the volume requested. (a beep sounds to confirm) (fig. right)

Switch on/off the lighting

  • Press the button to switch on/off the lighting.

DETECT THE LASER LINE

geo-FENNEL-FR-50-Rotating-Lasers-Receivers-FIG-11

  • The laser line is below the „0″ position
  • slow short beep
  • the upper red LED lights
  • Move the receiver down
  • The laser line is above the „O” position fast short beep the lower yellow LED lights => Move the receiver up
  • The laser line is not detected
  • no beep
  • no LED indication

SAFETY NOTES

CARE AND CLEANING

  • Handle measuring instruments with care. Clean with a soft cloth only after any use.
  • If necessary damp the cloth with some water.
  • If the instrument is wet clean and dry it carefully.
  • Pack it up only if it is perfectly dry. Transport in original container/case only.

ELECTROMAGNETIC ACCEPTABILITY (EMC)

  • It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems); and will be disturbed by other instruments (e.g. intensive electromagnetic radiation near industrial facilities or radio transmitters).

CE-Conformity

  • The instrument has the CE mark according to EN 61010-1:2001 + corrig. 1+2.

WARRANTY

  • This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at the manufacturer’s option), without charge for either parts or labor. In case of a defect please contact the dealer where you originally purchased this product.
  • The warranty will not apply to this product if it has been misused, abused, or altered. Without limiting the foregoing, leakage of the battery, and bending or dropping the unit are presumed to be defects resulting from misuse or abuse.

EXCEPTIONS FROM RESPONSIBILITY

  1. The user of this product is expected to follow the instructions given in the user manual.
    • Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance.
  2. The manufacturer, or its representatives, assumes no responsibility for the results of faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
  3. The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood, etc.), fire, accident, or an act of a third party and/or usage in other than usual conditions.
  4. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data interruption of business, etc., caused by using the product or an unusable product.
  5. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than explained in the user manual.
  6. The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connecting with other products.

SAFETY INSTRUCTIONS

  • Follow up on the instructions given in the user manual.
  • Use the instrument for measuring jobs only.
  • Do not open the instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
  • Do not remove warning labels or safety instructions.
  • Keep the instrument away from children.
  • Do not use the instrument in an explosive environment.
  • geo-FENNEL GmbH
  • Kupferstraße 6
  • D-34225 Baunatal
  • Tel. +49 561 / 49 21 45
  • Fax +49 561 / 49 72 34
  • [email protected]
  • www.geo-fennel.de
  • www.geo-fennel.com
  • www.geo-fennel.fr

Documents / Resources

| geo- FENNEL FR 50 Rotating Lasers Receivers [pdf] User Manual
FR 50 Rotating Lasers Receivers, FR 50, Rotating Lasers Receivers, Lasers Receivers, Receivers
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

geo-FENNEL User Manuals

Related Manuals