Geo-FENNEL FIRT 550-Pocket Infrared Thermometers User Manual

June 9, 2024
geo-FENNEL

Geo-FENNEL FIRT 550-Pocket Infrared Thermometers User Manual

Dear customer,

Thank you for your confidence in us having purchased a geo-FENNEL instrument. This manual will help you to operate the instrument appropriately.
Please read the manual carefully – particularly the safety instructions. A proper use only guarantees a longtime and reliable operation.
geo-FENNEL Precision by tradition.

Contents

1. Intended use of instrument A
2. Application B
3. Supplied with C
4. Features D
5. Front panel E
6. Display F
7. Operation G
8. Emissivity values H
9. Care and cleaning I
10. Saftey instructions J

A INTENDED USE OF INSTRUMENT

IR-Thermometer FIRT 550-Pocket is suitable for non-contact measurements with laser dot. Quick measurements of surfaces that are difficult to reach, that are moving or rotating, that are electrified or that are hot. The energy reflected from the surface measured is transferred into a temperature reading.
The instrument is not suitable for measuring surface temperature of shiny or polished surfaces (see emissivity). The instrument cannot measure through glass or other transparent materials. It will measu- re the temperature of the glass instead. Steam, dust and smoke can prevent from exact measurement as they would obstruct the instrument’s optic.

B APPLICATION

Food industry safety and fire inspectors, moulding industry, road building, screen printing, dryer tempe- rature, fleet maintenance.

Technical Data

Distance : Spot Size (D:S) 12 : 1
Resolution display 0,1°C
Accuracy for targets
•  -50°C to +20°C ± 2,5°C
•  +20°C to +300°C ± 1,0 %
• +300°c to +550°C ± 1,5 %
Repeatability
•  -50°C to +20°C ± 1,3°C
•  +20°C to +550°C ± 0,5 % or ± 0,5°C
Response time 0,15 sec.
Spectral response 8-14 μm
Emissivity adjustable 0,10 to 1,00
Laser diode < 1mW
Wave length 630 – 670 nm
Laser class 2
Operating temperature 0°C to + 50°C
Storage temperature -10°C to -60°C
Power supply 9V Batterie
Dimensions 150 x 90 x 40 mm
Weight 176 g

SUPPLIED WITH C

Infrared-Thermometer FIRT 550-Pocket, battery, case, manual.

FEATURES D

  • Fast temperature detection
  • Precise non-contact measurements
  • Dual laser sighting
  • Ergonomic housing
  • Automatic HOLD function
  • °C / F° switch
  • Emissivity adjustable from 0,10 to 1,00
  • Display of maximum value
  • LCD display with illumination
  • Selection of high / low alarm

E FRONT PANEL

  1. IR Sensor
  2. LCD display 1
  3. ▲ button / laser pointer (for EMS, HAL, LAL)
  4. ▼ button / illumination (for EMS, HAL, LAL) 2
  5. MODE button (for menu navigation)
  6. Measuring trigger
  7. Battery compartment cover 3
  8. Handle

DISTANCE (D) : SPOT SIZE (S)

**** The distance:spot ratio is important for evaluation of the area measured. The larger the distance from the object the larger the area measured. Switch on the laser pointer for increasing target accuracy.

Note:

The target must be larger than the instrument’s spot size. The smaller the target the shorter the distance should be.

OPERATION C

SWITCH INSTRUMENT ON/OFF

Pull the measuring trigger to switch instrument on. After 7 seconds it automatically switches off if no other key has been used. There is no special key to switch off the instrument.

CARRYING OUT MEASUREMENTS

Hold the instrument by its handle and point towards the area to be measured. Pull and hold the trigger to turn the instrument on and carry out measuring process. Release the trigger and HOLD will be displayed indicating that reading is held for about 7 seconds. If no other button is used instrument will automatically switch off after 7 seconds.

LASER POINTER

For exact targeting the area to be measured switch on laser pointer with ▲ button during HOLD mode. The laser icon will be displayed. Please take care to the explanations given regarding Distance: Spot- Ratio.

ILLUMINATION

In bad light conditions the illumination can be switched on with ▼ button during HOLD mode.

EMISSIVITY

The emissivity is a term used to describe the energy-emitting characteristics of a material. Most (90 % of typical applications) organic materials and painted or oxidized surfaces have an emissivity of ,95 (pre-set in the unit). Inaccurate reading will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape. Press MODE button (5) and „E“ starts blinking. The required emissivity can be set with ▼ / ▲ buttons.

H EMISSIVITY VALUES

Material Emissivity Material Emissivity
Asphalt 0,90 – 0,98 Cloth (black) 0,98
Concrete 0,94 Human skin 0,98
Cement 0,96 Lather 0,75 – 0,80
Sand 0,90 Charcoal 0,96
Earth 0,92 – 0,96 Lacquer 0,80 – 0,95
Water 0,92 – 0,96 Lacquer 0,97
Ice 0,96 – 0,98 Rubber (black) 0,94
Snow 0,83 Plastic 0,85 – 0,95
Glass 0,90 – 0,94 Timber 0,90
Ceramic 0,90 – 0,94 Paper 0,70 – 0,94
Marble 0,94 Chromium ox. 0,81
Plaster 0,80 – 0,90 Copper ox. 0,78
Mortar 0,89 – 0,91 Iron ox. 0,78 – 0,82
Brick 0,93 – 0,96 Textiles 0,90

TEMPERATURE UNITS

Measured temperatures will be indicated in °C or °F. Open handle grip and switch from °C to °F. Close handle grip again.

MAX TEMPERATURE INDICATION

The display shows the maximum temperature measured during measuring procedure (from pulling to releasing the trigger (display icon 8).

Note:

In case of large fluctuation of temperature (if instrument has been stored in cold area and is to be used in warm area – or the other way round – wait some minutes before carrying out measurements

MODE BUTTON

Menu navigation with the MODE button:

Press MODE button 1 x

Set emissivity with buttons ▼ / ▲.

Press MODE button 2 x

Switch on/off LOCK with buttons ▼ / ▲. When trigger is locked unit will continuously display temperature. Press trigger to switch off LOCK.

MODE

Press MODE button 3 x

Enter high alarm mode with buttons ▼ / ▲. Press MODE button again to set high alarm value.

Press MODE button 5 x

Enter low alarm mode with buttons ▼ / ▲.
Press MODE button again to set low alarm value.

i CARE AND CLEANING

CHANGE OF BATTERY
If symbol  is displayed battery must be replaced. Open battery cover, take off exhausted battery,
put in new 9V battery (take care to polarity) and close battery cover. Clean with soft cloth only. Do not use detergents.

J SAFTEY INSTRUCTIONS

  • Please follow up instructions given in operators’ manual.
  • Carefully read users’ manual before
  • Do not stare into laser Laser beam can lead to eye injury.
  • A direct look into the beam (even from greater distance) can cause damage to your
  • Do not aim laser beam at animals or
  • Laser plane should be set up above eye level of
  • Do not open instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local
  • Use the instrument for measuring surface temperature only.
  • Do not remove warning labels or safety
  • Keep instrument away from
  • Do not use instrument in explosive
  • It cannot be completely excluded that this instrument will disturb other instruments or will be disturbed by other

WARRANTY

  • This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of
  • During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufacturers option), without charge for either parts or
  • In case of a defect please contact the dealer where you originally purchased this
  • The warranty will not apply to this product if it has been misused, abused or
  • Without limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or

EXCEPTIONS FROM RESPONSIBILITY

  • The user of this product is expected to follow the instructions given in operators’ manual. Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general
  • The manufacturer, or its representatives, assumes no respon-sibility of results of a faulty or intentio- nal usage or misuse including any direct, indirect, consequential damage, and loss of
  • The manufacturer, or its representatives, assumes no respon-sibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood ), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
  • The manufacturer, or its representatives, assumes no respon-sibility for any damage, and loss of profits due to a change of data, loss of data and interruption of business , caused by using the product or an unusable product.
  • The manufacturer, or its representatives, assumes no respon-sibility for any damage, and loss of profits caused by usage other than explained in the users‘
  • The manufacturer, or its representatives, assumes no respon-sibility for damage caused by wrong movement or action due to connecting with other

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals