geo-FENNEL FPL-L-GREEN Positioning Lasers User Manual
- June 13, 2024
- geo-FENNEL
Table of Contents
geo-FENNEL FPL-L-GREEN Positioning Lasers
Product Information
The FLP L-GREEN and FLP C-GREEN are laser positioning devices used for marking
and positioning in various manufacturing, industrial, and craft sectors. The
FLP L-GREEN projects a visible laser line, while the FLP C-GREEN projects a
visible laser cross. They are capable of generating reference lines for
cutting wood, stone, metal, and concrete.
Technical Specifications
- Laser Diode: Green
- Laser Class: 2
- Focusing Range: 0 – 10m (FPL L-GREEN only)
- Power Supply: 220V
- Temperature Range: Not specified
- Dust/Water Protection: IP 41
- Weight: 0.385 kg
Product Usage Instructions
- Place the laser in the desired position. The greater the distance to the target, the longer the laser line.
- Connect the laser to the power supply and plug it into a socket.
- Power on the unit using the ON/OFF switch (1).
- Project the desired laser line or laser cross.
- Use the adjusting screws to set up the laser line or laser cross in its final position.
- If using the FPL L-GREEN model, use the rotary switch (3) to focus the laser line.
Power Supply
The product requires a 220V power supply. Connect the power supply to the
device using the provided switch and plug.
Additional Information
Please visit the following websites for more information:
Important Notes
- Read the safety instructions in the manual carefully before operating the device.
- Ensure proper use of the product for long-term and reliable operation.
Specific Reasons for Erroneous Measuring Results
- Measurements through glass or plastic windows.
- Dirty laser-emitting windows.
- After the instrument has been dropped or hit, check the accuracy.
- In cases of large temperature fluctuations, wait a few minutes before taking measurements if the instrument has been stored in a different temperature environment.
Dear customer
Thank you for your confidence in us having purchased a geo-FENNEL instrument.
This manual will help you to operate the instrument appropriately. Please read
the manual carefully – particularly the safety instructions. Proper use only
guarantees a long and reliable operation.
geo-FENNEL
Precision by tradition
SUPPLIED WITH FPL L-GREEN
Positioning line laser FPL L-GREEN
- Multi-functional mount (rotatable and swivelling)
- Power switch with plug (built-in)
- User manual
FPL C-GREEN
- Positioning cross-line laser FPL C-GREEN
- Multi-functional mount (rotatable and swivelling)
- Power switch with plug (built-in)
- User manual
CHARACTERISTICS
- Positioning lasers are especially suited for use in the manufacturing industry and in trade for marking and positioning.
- Projects a clearly visible laser line (positioning line laser FPL L-GREEN) / a clearly visible laser cross (positioning cross-line laser FPL C-GREEN)
- Marking of reference lines for cutting wood, stones, steel, and concrete
Technical data
Technical data
| FPL L- GREEN|
Laser diode| green
Laser class| 2
Focusing| 0 – 10 m /
| focusable
Fan angle| 80 °
Power supply| 220V
Temperature range| -10°C – +40°C
Dust/water protection| IP 41
Weight| 0,385 kg
|
Divergent data|
FPL C-GREEN|
Focusing| 10 m fix
Fan angle| 110°
Dust/water protection| IP 43
Weight| 0,45 kg
POWER SUPPLY
Power supply 220 V with switch and plug
OPERATION
FEATURES
- ON/OFF switch
- Laser emitting point
- Rotary switch for focusing (for model FPL L-GREEN only)
- Adapter power supply
- Power supply
- Multi-functional mount
OPERATION
Place the laser in the desired position. (The greater the distance to the
target, the longer the laser line). Connect the laser to the power supply and
plug it into a socket. Power on the unit with a button (1). Now project the
desired laser line / the desired laser cross. Use the adjusting screws to set
up the laser line/laser cross in its final position. Modell FPL L-GREEN: Focus
the laser line with the rotary switch (3).
SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS
Measurements through glass or plastic windows; dirty laser emitting windows;
after the instrument has been dropped or hit. Please check the accuracy. Large
fluctuation of temperature: If the instrument will be used in cold areas after
it has been stored in warm areas (or the other way round) please wait some
minutes before carrying out measurements.
CARE AND CLEANING
Handle measuring instruments with care. Clean with a soft cloth only after any
use. If necessary damp the cloth with some water. If the instrument is wet
clean and dry it carefully. Pack it up only if it is perfectly dry. Transport
in the original container/case only.
ELECTROMAGNETIC ACCEPTABILITY (EMC)
It cannot be completely excluded that this instrument will disturb other
instruments (e.g. navigation systems); and will be disturbed by other
instruments (e.g. intensive electromagnetic radiation nearby industrial
facilities or radio transmitters).
CE-Conformity
The instrument has the CE mark according to EN 61010-1:2001 + co rrig. 1+2.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at the manufacturer’s option), without charge for either parts or labour. In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused or altered. Without limiting the foregoing, leakage of the battery, and bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
- The user of this product is expected to follow the instructions given in the user manual. Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance.
- The manufacturer, or its representatives, assumes no responsibility of the results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
- The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
- The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data interruption of business etc., caused by using the product or an unusable product.
- The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by the usage of other than explained in the user manual.
- The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connecting with other products
INTENDED USE OF INSTRUMENT
The instrument emits a visible laser beam in order to carry out the following
measuring tasks (depending on the instrument): Setting up heights, horizontal
and vertical planes, and right angles.
SAFETY INSTRUCTIONS
- Follow up on the instructions given in the user manual.
- Do not stare into the beam. The laser beam can lead to eye injury. A direct look into the beam (even from a greater distance) can cause damage to your eyes.
- Do not aim the laser beam at persons or animals.
- The laser plane should be set up above the eye level of persons.
- Use the instrument for measuring jobs only.
- Do not open the instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
- Do not remove warning labels or safety instructions.
- Keep the instrument away from children.
- Do not use the instrument in an explosive environment.
- The user manual must always be kept with the instrument.
LASER CLASSIFICATION
The instrument is a laser class 2 laser product according to DIN IEC
60825-1:2014. It is allowed to use the unit without further safety
precautions. Eye protection is normally secured by aversion responses and the
blink reflex. The laser instrument is marked with class 2 warning labels.