geo FENNEL FIRT 800-Pocket Infrared Thermometers User Manual

June 9, 2024
geo-FENNEL

geo FENNEL FIRT 800-Pocket Infrared Thermometers

geo FENNEL FIRT 800-Pocket Infrared Thermometers

Product Information

The geo-FENNEL FIRT 800-Pocket is an infrared thermometer that is suitable for non-contact measurements with a laser dot. It is designed for quick measurements of surfaces that are difficult to reach, moving or rotating, electrified, or hot. The energy collected from the surface measured is transferred into a temperature reading. The instrument is not suitable for measuring the surface temperature of shiny or polished surfaces and cannot measure through glass or other transparent materials. The instrument comes with a battery, case, and manual.

Product Usage

To use the geo-FENNEL FIRT 800-Pocket, follow the steps below:

  1. Switch on the instrument by pressing the measuring trigger button.
  2. Point the laser pointer at the surface to be measured.
  3. Press the measuring trigger button to take the temperature reading.
  4. Use the q button to turn on the illumination if needed.
  5. Use the p button to turn on the laser pointer if needed.
  6. Use the MODE button to navigate the menu and set EMS, HAL, LAL, C/F, MAX/MIN, and LOW values.
  7. To switch off the instrument, press and hold the measuring trigger button for 3 seconds.
  8. If the battery needs to be replaced, open the battery compartment cover and replace it with a new one.

Note: The instrument can be used in various industries such as food industry safety and fire inspectors, molding industry, road building, screen printing, dryer temperature, and fleet maintenance. Please read the manual carefully before use and follow all safety instructions to ensure proper use and reliable operation of the instrument.

Technical Data

Distance : Spot Size (D:S) 10 : 1
Measuring range -35°C – +800°C
Icon “Out of measuring range” „ __ “
Temperature display (-) Minus / ( ) Plus
Resolution display 0,1°C
Accuracy targets +18 °C to + 28°C 80 % RH
Accuracy with ambient temperature
•  -35°C to +20°C ± 2,5°C
•  +20°C to +300°C ± 1,0 %
• +300°C to +800°C ± 1,5 %
Response time 0,3 sec.
Spectral response 8-14 μm
Emissivity adjustable 0,10 to 1,00
Laser diode < 1mW
Wave length 630 – 670 nm
Laser class 2
Operating temperature 0°C to + 50°C
Storage temperature -10°C to -60°C
Rel. humidity operation 10 % – 90 %
Rel. humidity storage < 80 %
Power supply 9V battery
Dimensions 160 x 42 x 82 mm
Automatic power off 7 sec.
Weight 176 g

SUPPLIED WITH
Infrared-Thermometer FIRT 800-Pocket, battery, case, manual.

FEATURES

  • Fast temperature detection
  • Precise non-contact measurements
  • Dual laser sighting
  • Automatic HOLD function
  • °C / F° switch
  • Emissivity adjustable from 0,10 to 1,00
  • Display of minimum/maximum value
  • LCD display with illumination
  • Selection of high / low alarm
  • Permanent measurements

FRONT PANEL

  1. IR-Sensor
  2. Laser pointer
  3. LCD display
  4. button/illumination
  5. button/laser pointer
  6. MODE button
  7. Measuring trigger
  8. Battery compartment cover
  9. Handle

DISPLAY

  1. MAX/MIN indication
  2. Measured temperature
  3. SCAN icon = measuring mode
  4. HOLD icon
  5. Icon „Laser on“
  6. LOCK icon
  7. Icon High alarm
  8. Icon Low alarm
  9. °C icon
  10. °F icon
  11. Battery status indication
  12. Emissivity

KEYPAD

  1. p-button (for EMS, HAL, LAL)
  2. button (for EMS, HAL, LAL)
  3. MODE button (for menu navigation)

OPERATION

SWITCH INSTRUMENT ON/OFF
Pull the measuring trigger to switch instrument on. After 7 seconds it automatically switches off if no other key has been used. There is no special key to switch off the instrument.

CARRYING OUT MEASUREMENTS
Hold the instrument by its handle and point towards the area to be measured. Pull and hold the trigger to turn the instrument on and carry out measuring process. Release the trigger and HOLD will be displayed indicating that reading is held for about 7 seconds. If no other button is used instrument will automatically switch off after 7 seconds.

LASER POINTER
For exact targeting the area to be measured switch on laser pointer with button during HOLD mode. The laser icon will be displayed.
Please take care to the explanations given regarding Distance: Spot-Ratio.

ILLUMINATION
In bad light conditions the illumination can be switched on with  button during HOLD mode.

EMISSIVITY
The emissivity is a term used to describe the energy-emitting characteristics of a material. Most (90 % of typical applications) organic materials and painted or oxidized surfaces have an emissivity of, 95 (pre-set in the unit). Inaccurate reading will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape. Press MODE button (5) and „E“ starts blinking. The required emissivity can be set with q / p buttons.

EMISSIVITY VALUES

Material Emissivity Material Emissivity
Asphalt 0,90 – 0,98 Cloth (black) 0,98
Concrete 0,94 Human skin 0,98
Cement 0,96 Lather 0,75 – 0,80
Sand 0,90 Charcoal 0,96
Earth 0,92 – 0,96 Lacquer 0,80 – 0,95
Water 0,92 – 0,96 Lacquer 0,97
Ice 0,96 – 0,98 Rubber (black) 0,94
Snow 0,83 Plastic 0,85 – 0,95
Glass 0,90 – 0,94 Timber 0,90
Ceramic 0,90 – 0,94 Paper 0,70 – 0,94
Marble 0,94 Chromium ox. 0,81
Plaster 0,80 – 0,90 Copper ox. 0,78
Mortar 0,89 – 0,91 Iron ox. 0,78 – 0,82
Brick 0,93 – 0,96 Textiles 0,90

Note:
In case of large fluctuation of temperature (if instrument has been stored in cold area and is to be used in warm area – or the other way round) wait some minutes before carrying out measurements.

DISTANCE (D) : SPOT SIZE (S)

The distance:spot ratio is important for evaluation of the area measured. The larger the distance from the object the larger the area measured. Switch on the laser pointer for increasing target accuracy.

Note:
The target must be larger than the instrument’s spot size. The smaller the target the shorter the distance should be.

MODE BUTTON

Menu navigation with the MODE button:geo FENNEL FIRT 800-Pocket Infrared
Thermometers fig-8

Press MODE button 1 x
Set emissivity with buttons.

Press MODE button 2 x
Set temperature units with °C / °F with buttons.

Press MODE button 3 x
Set minimum or maximum values with buttons. [(indication: small number displayed (1)].

Press MODE button 4 x
Switch LOCK on/off with buttons. If LOCK is switched on a permanent measurement will be carried out. Pull trigger to switch LOCK off.

Press MODE button 5 x
Enter high alarm mode with buttons. Press MODE again to set values.

Press MODE button 7 x
Enter low alarm mode with buttons. Press MODE again to set values.

SAFTEY INSTRUCTIONS

  • Please follow up instructions given in operators’ manual.
  • Carefully read users’ manual before operation.
  • Do not stare into laser beam. Laser beam can lead to eye injury.
  • A direct look into the beam (even from greater distance) can cause damage to your eyes.
  • Do not aim laser beam at animals or persons.
  • Laser plane should be set up above eye level of persons.
  • Do not open instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
  • Use the instrument for measuring surface temperature only.
  • Do not remove warning labels or safety instructions.
  • Keep instrument away from children.
  • Do not use instrument in explosive environment.
  • It cannot be completely excluded that this instrument will disturb other instruments or will be disturbed by other instruments.

WARRANTY

  • This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase.
  • During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufacturers option), without charge for either parts or labour.
  • In case of a defect please contact the dealer where you originally purchased this product.
  • The warranty will not apply to this product if it has been misused, abused or altered.
  • Without limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.

EXCEPTIONS FROM RESPONSIBILITY

  • The user of this product is expected to follow the instructions given in operators’ manual. Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance.
  • The manufacturer, or its representatives, assumes no respon-sibility of results of a faulty or intentio-nal usage or misuse including any direct, indirect, consequential damage, and loss of profits.
  • The manufacturer, or its representatives, assumes no respon-sibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
  • The manufacturer, or its representatives, assumes no respon-sibility for any damage, and loss of profits due to a change of data, loss of data and interruption of business etc., caused by using the product or an unusable product.
  • The manufacturer, or its representatives, assumes no respon-sibility for any damage, and loss of profits caused by usage other than explained in the users‘ manual.
  • The manufacturer, or its representatives, assumes no respon-sibility for damage caused by wrong movement or action due to connecting with other products.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

geo-FENNEL User Manuals

Related Manuals