CAPITOL 110400 Seaming Iron Owner’s Manual

May 15, 2024
CAPITOL

CAPITOL 110400 Seaming Iron

CAPITOL 110400 Seaming Iron

WARNING Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious bodily injury. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY RULES

Symbol Read and understand all instructions. Failure to follow the instructions may result in electric shock, fire, serious personal injury, or damage to carpet.

SAVE THESE INSTRUCTIONS

Work Area
Do not expose to water or use in a damp or wet location. Keep work area clean and well lit. Do not use in the presence of flammable liquids or gases.

Personal Safety
Stay alert. Watch what you are doing and use common sense when operating. Do not use while tired or under the influence of drugs, alcohol or medication. Dress properly. Do not wear loose clothing or jewelry. Keep long hair, clothing and jewelry away from iron. Wear gloves when seaming. Avoid touching the heat shield or base when in use.

TOOL USE AND CARE

Symbol This iron is used for melting adhesive on Heat Bond Carpet Seaming Tape. It is not intended for any other use. This iron is intended for indoor use only.

The handle of the iron is molded from durable fiberglass filled nylon material.
The base is non-stick coated die-cast aluminum and the iron is equipped with an insulated stainless steel heat shield.

Iron runs on 120-volt standard U.S. electrical current. Do not change cords, plugs or electrical components. Take the iron to an authorized repair shop for repairs. Do not pull the plug from the socket with the cord. Grasp the plug and pull from the socket.

Specifications 110400

Amps 6.6A
Watts 800W
Approx Heat Range 125.6° F ~ 428° F (52° C ~ 220° C)
Volts ~120

Extension Cords
Only use extension cords that are intended for indoor use. These extension cords are identified by the statement: “Acceptable for use with indoor appliances; store indoors while not in use”. Only use extension cords with an electrical rating that is higher than the rating of the product. Do not use damaged extension cords. Examine extension cord before using and replace if damaged. Do not abuse extension cords and do not yank on any cord to disconnect. Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord. Keep cord away from heat and sharp edges.

WARNING – To reduce the risk of electric shock, keep all connections dry and off the ground. Do not touch plug with wet hands.

USING YOUR CAPITOL SEAMING IRON

  1. Select a clear area near the beginning of the carpet seam to place iron for heating.
  2. Place all required materials and tools within reach.
  3. Set the iron in its base and place the base on a solid surface, such as a piece of plywood or a piece of scrap carpet.
  4. If needed, make sure an extension cord is long enough to reach the end of the seam.
  5. Plug the iron into a household (120-volt) socket and set the thermostat control located on the front of the handle to desired temperature setting. Consult tape manufacturer’s instructions for the proper heat range. The chart below shows the thermostat knob settings for various temperature ranges.
    NOTE: Recommended setting for Capitol® Heat Bond tapes is 2-3 on the temperature control knob.
    ** Number on Knob**|

Temperature Range

| Time to Reach Temperature
---|---|---
Min ˚F| Max ˚F| Min ˚C| Max ˚C
1
1½| 125.6 ˚ F
170 ˚ F| 161.6 ˚ F
224 ˚ F| 52˚C
76˚C| 72˚C
107˚C| 1½ minutes
2 minutes
2

3| 212 ˚ F
266 ˚ F
330.8 ˚ F| 253.4 ˚ F
322 ˚ F
366.8 ˚ F| 100˚C
129˚C
166˚C| 123˚C
161˚C
186˚C| 2½ minutes
3 minutes
3½ minutes

4| 339 ˚ F
392 ˚ F| 396 ˚ F
428 ˚ F| 170˚C
200˚C| 203˚C
220˚C| 3¾ minutes
4 minutes
6. Allow the iron to reach operating temperature according to the chart above. The light on top of the handle will stay red while the iron is heating. The light will turn green when the iron has reached operating temperature. 7. Let the iron cycle several times before seaming. 8. Test the iron for proper temperature on tape or a piece of scrap tape to get the desired melting of the adhesive.

MAINTENANCE OF NON-STICK COATED BASE PLATE

The base plate is coated with a tough non-stick coating to provide a long lasting easy to clean surface. To preserve this finish:

  1. Always put the iron in its holder when not seaming.
  2. Never try to clean the base with a wire brush, knife, or any hard material.
  3. Do not place iron on concrete or other hard surfaces.
  4. When storing, put the iron in its holder.
  5. ALWAYS CLEAN IRON AFTER EVERY USE.
  6. To clean iron, rub the base over a piece of clean scrap carpet while the iron is still hot.

CUSTOMER SERVICE NUMBER: 1-866-435-8665

CAPITOL 110400

HEAT-BOND SEAMING IRON

Heat-bond Seaming Iron

REPLACEMENT PARTS LIST

Part Description
110400-01B Handle Set with (8) Screws
10-282-02B Cord Set Includes Cord Relief Spring, Wire Connection Clip and (4)

Screws
10-282-03A| Thermostat
10-282-04| Top Sole Plate with (5) Screws
10-282-06| Bottom Sole Plate, Non-stick, Grooved
10-282-07B| Internal Wire Set (2 pieces)
10-282-08B| Calibration Knob with Extension Post for Control Knob
10-282-09| Heat Shield with (2) Screws and (1) Washer
10-282-10| Gasket (top of Heat Shield for Handle Mount)
10-282-11| Gasket (between Heat Shield and top of Sole Plate)
10-282-12A| Heating Element
10-177-06| Iron Holder

CAPITOL® Flooring Products
Dalton, GA 30720
Made in Korea • Fabriqué en Corée • Hecho en Corea
www.capitolflooringproducts.com
CUSTOMER SERVICE: 1-866-435-8665

CAPITOL Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals