phocos MXI-IR PC USB Interface Installation Guide
- June 4, 2024
- phocos
Table of Contents
MXI-IR PC USB Interface
**Installation Guide
**
MXI-IR PC USB Interface
MXI-IR Driver Installation Guide Windows 7
Software for Phocos CIS Controller Series: Single Load: CIS, CIS-N, CIS-LED,
CIS-MPPT Dual Load: CIS, CIS-N
www.phocos.com
Before You Begin
Dear customer,
Please download the CISCO software, and extract the files using the Windows
“Extract All” feature (or equivalent program).
Note: The drivers from the compressed files will not work, and your
installation will fail. This is normal. Take note of the file location on your
computer.
Plug in your MXI-IR to a free USB port on your computer.
You are now ready to begin.
Software Features/Controller
2.1. STEP 1: Open the Device Manager
One way to do this is to click the “Start” button, then right-click on the
“Computer” menu option, and then click “Manage”. This will open the “Computer
Management”. Click on “Device Manager”. Use the following three screenshots to
guide you
2.2. STEP 2: Update the MXI-IR Driver Manually
Locate the “Phocos MXI-IR” in your device list under “Other Devices”. (Older
versions may list “Phocos CXI” or “USB Serial Port” under “Other Devices”.)
Select “Browse my computer for driver software”.
Use the “Browse” button to find the location on your computer where you saved
the extracted CISCOM files, and find the “MXI-IR_Interface_Driver” folder.
This folder will contain folders titled various Windows operating systems.
Select the “Windows_7” folder.
Windows will install the drivers.
You may see the following screen saying that Windows cannot verify the
publisher.
Select “Install this driver software anyway”. (This is normal because Phocos
is not yet a verified publisher with Microsoft.)
Once the installation is complete, the following screen will appear stating
that the driver was updated successfully.
Use With CISCOm
The CISCOM software requires the correct COM port to be selected for use when
the MXI-IR is used to communicate with a CIS controller Open the CISCOM
program, and select “Interface” in the upper left corner of the window. (You
may not see any COM ports listed.) Select “Refresh COM PORTS”.
Select the “Interface” menu again, and select a COM port. If there is more
than one listed, pick the first one.
3.1. Verification Without a Controller
Select the “Read Controller Settings” button. If it is the correct COM port,
the “Communicating…” notification will be displayed.
Then the following error message will be displayed: “Communication failed. No
data received. Error code: 2”. This verifies a correct install of the MXI-IR
driver.
3.2. Verification With a Controller
Ensure that the CIS controller is powered on. This will be indicated by either
a solid green LED or a flashing green LED on the controller. Point the
infrared transceiver of the MXI-IR to the infrared transceiver of the CIS
controller. Select the “Read Controller Settings” button. If it is the correct
COM port, the “Communicating…” notification will be displayed.
When communication is successfully finished, the settings menus will be
displayed with the controller’s settings similar to the diagram below. If no
error message is displayed, this verifies a correct install of the MXI-IR
driver.
3.3. Problems During Verification
If your first COM port selection was incorrect, the following error message
will be displayed. “Communication failed. Unable to open the port. Error code:
1”
Select “OK”, and then choose the next COM port from the Interface Menu. Repeat
the process until you can verify your driver was installed correctly.
Note: The controller must be connected to a battery in order to send or
receive information with MXI-IR. For additional support, please contact us.