WMF 1300 S Fully Automatic Coffee Machines Instructions
- June 4, 2024
- WMF
Table of Contents
WMF coffeemachines
WMF 1300 S planning information
WMF 1300 S Fully Automatic Coffee Machines
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water, and drainage
connections at the customer‘s premises is to be arranged by the machine
owner/operator. The work must be carried out by authorized installation
technicians in compliance with general, country-specific, and local
regulations. The WMF service engineers may only connect the coffee machine to
existing prepared connection points. WMF Service is neither authorized nor
responsible for carrying out any on-site installation work prior to
connection. The potential equalisation terminal is installed by WMF Service if
needed.
Dimensions and empty weight| Width Height Depth
Clearance height Weight| 325 mm
669 mm
561 mm
60 – 169 mm
Approx. 35 kg (depending on the model)
---|---|---
Water supply| Water supply line
Inlet temperature
Water drain tube (optional)| 3/8 inch hose connector with mains tap and filter
with 0.08 mm mesh size, on-site. At least 0.2 MPa (2 bar) flow pressure at 2
l/min (standard). Maximum 0.6 MPa (6 bar).
Maximum 35 °C.
Tube a minimum of DN 19, a minimum downward slope of 2 cm/m
For use at altitude above NN| < 2000 m|
Electrical data| Nominal power rating| 2.0 – 2.4 kW
| Power supply| 220–240 V 50 / 60 Hz (1 / N / PE), country-specific power
supply available
| Degree of protection| IP X0
| Protection Class| I
Installation Clearance| For operating, service, and safety reasons the machine
should be installed with a clearance from the building or non-WMF components
of not less than 50 mm at the sides and 60 mm at the back. A minimum working
space of 800 mm in front of the coffee machine is recommended.
Clearance of at least 200 mm above the product hopper is recommended. The
height of the installation surface above the floor is at least 850 mm. If the
coffee machine connections are to be run downwards through the counter, please
make space for the lines, which can reduce the usable space below the machine.
If the coffee machine is operated with a water filter the additional space
under the machine depending on the filter size has to be considered. For
further information see filter instructions.
Installation surface/water spray| The device must be placed and leveled on a
horizontal, sturdy, water-resistant, and heatproof base. The device must not
be cleaned using a water jet. The device must be installed where it is
protected against water spray. The device must not be located on a surface
that is sprayed or cleaned with a water hose, steam jets, steam cleaner, or
similar devices.
Ventilation| If ventilation possibility is limited sufficient ventilation
needs to be provided e.g machine on feet extension, active ventilation, and
additional ventilation slots/ openings in the counter area. Ventilation slots
must not be covered. Under certain circumstances forced ventilation on site is
necessary to ensure heat dissipation.
Electrical connection|
These specifications for the electrical connection and the standards quoted
apply to connecting the coffee machine in the EU. It may be necessary to also
observe additional country-specific regulations. Outside the EU acceptance of
the standards quoted is to be checked by the legal entity or natural person
who wishes to use the coffee machine.
The customer’s on-site electrical system must be designed to meet country-
specific regulations per IEC 60364 and must match the information on the
rating plate. An isolated ground socket or a country-specific single-phase
socket for a single-phase connection, or a 5-pole CEE / CEKON socket per DIN
EN 50310 VDE 0800–2-310 or a country-specific multi-pole socket for a three-
phase connection, must be available near the machine. The sockets are part of
the customer‘s on-site installation. The main cable must not come into contact
with hot surfaces. If the mains cable for this device is damaged then it must
be replaced by our service personnel or a similarly qualified person, in order
to prevent hazards.
In order to avoid possible faults from arising in our shielded data lines due
to potential equalization currents between the devices, an additional
potential equalization unit should be planned for devices connected to the
vending system (see DIN EN 50310 VDE 0800–2-310).
If the machine is intended to be installed in a large kitchen, it is
recommended that it be equipped with a ground potential bonding conductor. The
potential equalisation terminal is installed by WMF Service if needed.
Important advice regarding accounting systems:
In case of operation with a card reader, an additional and separately fuse-
protected shockproof socket must be installed onsite if necessary depending on
the type of card reader. The supplier of the card reader is to be asked for
the required fuse protection. In order to prevent possibly occurring
disturbances of our screened data lines by potential equalization currents
between the units, an additional potential equalization according to VDE
should be provided for units connected to an accounting system.
---|---
Water supply and drainage|
The water supply must be located close to the machine (max. distance 800 mm).
An anytime easily accessible and sufficiently dimensioned water tap
(preferably ball tap) as well as a dirt filter with a mesh size of 0,080 mm
must be installed below the counter in the water supply.
For connection from below through the counter a cut-out must be made in the
hatched area on-site according to the drawing (see top view).
For drinking water with carbonate hardness above 5°dKH (carbonate hardness), a
WMF water filter should be fitted upstream.
If the coffee machine is connected to a drain connection, a funnel siphon must
be installed in the drain pipe.
Please observe that the free drain (funnel siphon with sheet metal angle) is
fitted vertically. This means that it must always be vertical to the water
back pressure level that is reached. It must be fitted in a way that the given
gradient of the drain hoses (2%) is observed. Additionally, the free drain
must always be below the drains of the coffee machine and above the actual
drain pipe connections (HT40, HT50, or similar) with respect to its height.
To a funnel siphon with sheet metal angle max. two coffee machines with DN19
hose and black silicone fabric hose should be connected. Other devices
(dishwasher, sink etc.) should be installed elsewhere.
The free drain incl. hoses must not be exposed to heavy tensile, pressure or
torsional load. Hereby, the damage might be caused to the mechanical
components of the free drain.
Consequently, its usability may get lost.
The on-site preliminary works for the drainage connection must be commissioned
by the operator of the machine. They must be carried out by concession
plumbers in compliance with the prevailing, national as well as local
regulations.
The following drawings serve to illustrate the drains and do not include any
other connections, such as power or water infeed!
Miscellaneous| Ambient temperature| +5 °C to maximum +35 °C (empty the water
system in case of frost).
---|---|---
| Maximum humidity| 80 % relative humidity without condensation. Do not use
the device outdoors.
| Heat dissipation| 0.056 kWh/h standby mode 2.3 kWh/h maximum use
| Continuous sound pressure level (Lpa)| < 70 dB(A)
For more information as the instruction manual, safety data sheets, and
certificates, see: http://mediacenter.wmf.com/servicecenter/
All information refers to coffee machines/ equipment as the standard versions.
Individual solutions can differ from the standard version.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 | 73312 Geislingen (Steige)