TROJAN TR GC2 Series 24V Lithium Ion Battery User Guide
- May 15, 2024
- TROJAN
Table of Contents
- CONGRATULATIONS
- THIS USER’S GUIDE
- YOUR TROJAN LITHIUM-ION BATTERY
- SAFETY
- EQUIPMENT NEEDED
- BATTERY INSTALLATION
- PREVENTATIVE MAINTENANCE
- Charging
- STORAGE AND SHIPPING
- MAXIMIZING THE PERFORMANCE OF YOUR BATTERY
- WHAT TO EXPECT FROM YOUR TROJAN LITHIUM-ION BATTERY
- ELECTRICAL SPECIFICATIONS
- TROJAN BATTERY COMPANY
- TECHNICAL SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TROJAN TR GC2 Series 24V Lithium Ion Battery
CONGRATULATIONS
on your purchase from Trojan Battery Company, LLC (“Trojan”), manufacturers of the world’s most trusted batteries. GC2 Lithium-Ion batteries are engineered for safety and performance—delivering faster charge times and longer runtimes with virtually zero required maintenance. It’s the next innovation in battery power backed by 100 years of expertise. We’re proud to continue our tradition of delivering clean, long-lasting and reliable batteries to power your world.
THIS USER’S GUIDE
was created by Trojan’s application engineers and contains vital information
regarding proper care and maintenance of your new battery. Please read through
this User’s Guide carefully and completely before using your battery.
It will help you achieve optimum performance and long life from your new
investment. If you have any questions concerning safety precautions or for any
assistance in installing or using the battery in your system, contact Trojan’s
technical support engineers at one of the following numbers, or send us an
email through our website at www.trojanbattery.com/tech-
support/.
YOUR TROJAN LITHIUM-ION BATTERY
The TR GC2 Series battery is a deep-cycle lithium-ion battery. Key attributes of the battery include:
KEY ATTRIBUTES
Nominal Voltage| 24V| 36V| 48V
Case Size| BCI Group Size GC2
Battery Voltage| 25.6| 38.4| 51.2
Capacity*| 65Ah| 45Ah| 30Ah
Terminal Configuration| M8-1.25 threaded studs
Communication Port| CAN Bus SAW J1939
A. Status Button
B. Negative Terminal (M8 size)
C. Battery Status Indicators (SOC)
D. Positive Terminal (M8 size)
E. Communications Port I/II
F. Lifting Brackets
*Temperature, load, state of charge, and battery age can affect battery performance and capacity.
SAFETY
ALWAYS | NEVER |
---|
Always wear proper personal protective equipment (PPE) (eye protection and
gloves).| Never wear jewelry or other metal objects when working on or around
batteries.
Always use insulated tools when working on batteries.| Never place objects on
top of batteries.
Always check connections for proper torque.| Never attempt to charge a battery
when the temperature is below 32°F (0°C) or above 113°F (45°C).
Always keep sparks and flames away from batteries. This includes sources of
static electricity.| Never store batteries below 30% State of Charge.
Always use short cables of appropriate size to minimize voltage drop.| Never
exceed maximum charging currents for the battery’s temperature.
Always make sure charger is set as recommended.| Never dispose of batteries as
household waste. Use recycling channels in accordance with local, state and
federal regulations.
Always charge batteries before installing.| Never connect or disconnect
terminals from batteries without first disconnecting loads.
Always make sure chargers are off or disconnected while working on batteries.|
Never attempt to open the battery case.
Always add additional TR GC2 Series batteries in parallel.| Never use pressure
washers to clean the battery or immerse the battery in water.
Always use battery lifting strap.| Never short-circuit the battery terminals.
Always review product warning labels and Trojan® GC2 Series Lithium-Ion User’s
Guide.| Never physically damage the battery (this includes, without
limitation): Puncturing, dropping, crushing, burning, penetrating, shaking,
hammering, and misconnecting terminals.
Always install batteries while powered off.| Never lift by the battery
terminals.
| Never over-charge or over-discharge the battery.
| Never attempt to connect TR GC2 Series batteries in series.
WARNING! RISK OF FIRE, EXPLOSION OR BURNS. DO NOT DISASSEMBLE, HEAT ABOVE 140°F (60°C) OR INCINERATE.
THE MOST EFFECTIVE FIRE EXTINGUISHER TYPES FOR TROJAN LITHIUM-ION BATTERIES ARE CO2 OR WATER. SEE SAFETY INSTRUCTIONS.
DANGER!
HOST SYSTEMS POWERED BY LITHIUM-ION BATTERIES, INCLUDING THE TROJAN® GC2
SERIES LITHIUM-ION BATTERY, MAY BEHAVE DIFFERENTLY THAN WHEN POWERED BY LEAD-
ACID BATTERIES. MOST NOTABLY LITHIUM-ION BATTERIES MAY DISCONNECT FROM THE
HOST SYSTEM WITHOUT WARNING UNDER A VARIETY OF CONDITIONS IN ORDER TO AVOID
INTERNAL DAMAGE (“AUTOMATIC DISCONNECTION”). AUTOMATIC DISCONNECTION WILL
RESULT IN TOTAL POWER LOSS.
EXAMPLES OF CONDITIONS THAT CAN LEAD TO AUTOMATIC DISCONNECTION INCLUDE, WITHOUT LIMITATION:
- HIGH VOLTAGE FROM EXTERNAL POWER SOURCES (CHARGERS) OR REGENERATIVE BRAKING
- BATTERY LOW VOLTAGE OR LOW STATE OF CHARGE
- HIGH CURRENT
- EXTERNAL SHORT CIRCUIT
- HIGH OR LOW TEMPERATURES
- SELF DIAGNOSTICS
- AFTER MARKET OR MODIFIED MOTOR CONTROLLERS.
FOR ADDITIONAL INFORMATION PLEASE SEE SECTION 10.3: “PROTECTION LIMITS: AUTOMATIC DISCONNECTION.”
IN EQUIPMENT WITH ESSENTIAL SYSTEMS THAT RELY ON BATTERY POWER (FOR EXAMPLE, LOW-SPEED VEHICLES WITH ELECTRONIC ACCELERATION AND BRAKING SYSTEMS) (EACH AN “AFFECTED APPLICATION”), AN ABRUPT INTERRUPTION OF POWER MAY RESULT
IN UNDESIRABLE, UNEXPECTED AND POTENTIALLY DANGEROUS EQUIPMENT BEHAVIOR, INCLUDING BUT NOT LIMITED TO BRAKING LOSS OR IMMEDIATE BRAKING.
USERS AND INSTALLERS OF THE LI GC2 MUST UNDERSTAND THE CONSEQUENCES OF
INSTALLING LITHIUM-ION BATTERIES IN AN AFFECTED APPLICATION.
THE USER AND/OR INSTALLER OF THE GC2 BATTERY (“USER AND/OR INSTALLER”) ASSUMES
ALL RISK AND LIABILITY FOR ANY DAMAGES, INJURIES TO PERSONS OR PROPERTY
(INCLUDING BUT NOT LIMITED TO DEATH), OR ACCIDENTS ARISING OUT OF OR RELATED
TO SUCH USE OR INSTALLATION.
USERS AND/OR INSTALLERS SHOULD CONSULT THE MANUFACTURER OF ANY AFFECTED
APPLICATION FOR RISK MITIGATION OPTIONS RELATED TO USE WITH LITHIUM-ION
BATTERIES.
DANGER!
LITHIUM-ION BATTERIES, INCLUDING THE TROJAN® GC2 SERIES LITHIUM-ION BATTERY, WEIGH SUBSTANTIALLY LESS THAN LEAD-ACID BATTERIES OF COMPARABLE CAPACITY. MANY TYPES OF EQUIPMENT ARE DESIGNED TO UTILIZE THE WEIGHT OF LEAD-ACID BATTERIES TO ACHIEVE THE MANUFACTURER’S INTENDED WEIGHT DISTRIBUTION. IF GC2 BATTERIES ARE INSTALLED AS REPLACEMENT BATTERIES IN EQUIPMENT DESIGNED TO USE LEAD-ACID BATTERIES AS BALLAST, THE WEIGHT DISTRIBUTION OF THE EQUIPMENT COULD BE IMPACTED. THE USER AND/OR INSTALLER OF THE GC2 BATTERY IN SUCH EQUIPMENT MUST UNDERSTAND THE CONSEQUENCES OF MODIFIED WEIGHT DISTRIBUTION AND ENSURE THAT STABILITY REMAINS WITHIN A SAFE RANGE FOR THE INTENDED USE. THE PROPER INSTALLATION OF GC2 BATTERIES MAY REQUIRE ADDITIONAL BALLAST WEIGHTS OR OTHER ADJUSTMENTS OR EQUIPMENT MODIFICATIONS TO ENSURE STABILITY AND SAFE WEIGHT DISTRIBUTION. THE IMPROPER INSTALLATION AND/OR USE OF GC2 BATTERIES COULD COMPROMISE THE WEIGHT BALANCE AND PHYSICAL STABILITY OF THE EQUIPMENT LEADING TO UNSAFE CONDITIONS. THE USER AND/OR INSTALLER OF THE GC2 BATTERY IN SUCH EQUIPMENT ASSUMES ALL RISK AND LIABILITY FOR ANY DAMAGES, INJURIES TO PERSONS OR PROPERTY (INCLUDING BUT NOT LIMITED TO DEATH), OR ACCIDENTS ARISING OUT OF OR RELATED TO DEGRADED STABILITY RESULTING FROM IMPROPER INSTALLATION AND/OR USE OF THE GC2 BATTERY.
EQUIPMENT NEEDED
Before installation or maintenance of your batteries, have the following equipment available:
- Proper personal protective equipment (eye protection and gloves)
- Battery charger
- 13mm socket
- Insulated tools
- Voltmeter (optional)
- Cables
The TR GC2 weighs 37 lbs. Use of a battery lifting strap to aid installation is recommended. Lifting strap must be designed and rated for lifting batteries and able to securely engage integrated lifting brackets.
BATTERY INSTALLATION
The Lithium-ion battery voltage must be matched to the vehicle where it is
installed. Connect batteries in parallel electrically when installing more
than one battery in your vehicle. Be sure to follow the instructions for
parallel installation. Installing multiple batteries in parallel ( See
Section 4.5: “Connecting Batteries in Banks”) increases the available
capacity and may be required to match the power requirements of your vehicle.
DO NOT CONNECT BATTERIES IN A SERIES. Series connection may pose danger to user and/or installer and cause damage to the battery. The installer should verify every battery is off before performing the installation procedure. See Section 4.9: “Battery Start-Up.” For operation and use, turn the battery back ON using the status button on each battery.
INSPECTION AND 12V ACCESSORIES
Check for visible damage including cracks, dents, deformation and other visible abnormalities. The tops of the batteries and terminal connections should be clean, free of dirt and corrosion, and dry. If any problems are detected with the batteries, contact Trojan technical support or your battery distributor. If damage occurred in transit, contact your freight carrier. To prevent damage to 12V accessories in the vehicle, first verify the voltage requirement of accessories like lights or others items in the vehicle. Never connect accessories directly to the battery. Lithium-ion batteries are more susceptible to permanent damage from parasitic loads than other battery types. If a continuous load such as a light, USB charger, voltage reducer, GPS or battery state of charge indicator is left connected to the battery for an extended period of time, a low voltage fault will occur. If left in this condition, the battery could become unrecoverable. All accessories should be wired through the vehicle key switch or another method of disconnecting the equipment from the battery when not in use. Then, if needed, the installer can use a voltage reducer to reduce the battery voltage to 12V or as required. To ensure you install your batteries properly and safely, please use the following guidelines.
TERMINALS AND TORQUE VALUES
Both the positive and negative terminals of the battery are M8-1.25 x 15mm threaded studs. Ensure that the nuts are tightened to the proper dry torque of 80-90 in•lbs (9-10Nm). OVER-TIGHTENING TERMINAL CONNECTIONS CAN CAUSE TERMINAL BREAKAGE, AND LOOSE CONNECTIONS CAN RESULT IN TERMINAL MELTDOWN OR FIRE.
CORRECT HARDWARE INSTALLATION
If using flat or lock washers, it is very important to ensure the battery cable lug is contacting the top surface of the terminal, and the washer is placed on top of the lug. DO NOT PLACE A WASHER BETWEEN THE BATTERY TERMINAL AND THE LUG, AS THIS WILL CREATE HIGH RESISTANCE AND CAUSE EXCESSIVE HEATING OF THE CONNECTION, WHICH CAN RESULT IN FIRE. If assistance is needed in determining the appropriate hardware configuration, contact Trojan Battery technical support.
CABLE SIZE
Battery cables should be sized to handle the expected load and be of sufficient length and flexibility to avoid applying undesirable mechanical loads on the battery terminals. Refer to Table 1 for the maximum amperage based on the cable/wire gauge size.
WARNING! SHOCK HAZARD – DO NOT TOUCH UN-INSULATED BATTERY, CABLES, OR TERMINALS. ALL TOOLS SHOULD BE ADEQUATELY INSULATED TO AVOID THE POSSIBILITY OF SHORTING CONNECTIONS. DO NOT LAY TOOLS ON THE TOP OF THE BATTERY.
CABLE/WIRE GAUGE SIZE, AWG (mm2) | AMPACITY (Amps) |
---|---|
14 (2.08) | 20 |
12 (3.31) | 25 |
10 (5.26) | 35 |
8 (8.36) | 50 |
6 (13.3) | 65 |
4 (21.1) | 85 |
2 (33.6) | 115 |
1 (42.4) | 130 |
1/0 (53.5) | 150 |
2/0 (67.4) | 175 |
TABLE 1
Table values are from NEC Table 310.15(B)16 for copper cables rated at 167°F
(75°C), operating at an ambient temperature of no more than 86°F (30°C).
Lengths in excess of 6 feet (1829mm) may require heavier gauge wire to avoid
unacceptable voltage drop. In parallel battery banks, it is preferable for all
cables to be the same length.
For more information refer to the National Electrical Code for correct
cable/wire size, which can be located at www.nfpa.org.
CONNECTING BATTERIES IN BANKS
You can increase the vehicle range and battery power capability by connecting multiple batteries together in parallel electrically as shown in Table 2.
WARNING! SHOCK HAZARD; RISK OF FIRE. ATTEMPTING TO USE THIS BATTERY IN HIGHER VOLTAGE SYSTEMS OR CONNECTING IN SERIES MAY BYPASS INTERNAL BATTERY SAFETY FEATURES AND CREATE A HAZARDOUS SITUATION. PERSONAL PROTECTIVE EQUIPMENT RECOMMENDED IN THIS USER GUIDE MAY BE INADEQUATE IF BATTERY IS MISUSED IN THIS WAY. REFER TO NFPA 70E OR LOCAL ELECTRICAL SAFETY GUIDELINES FOR ADDITIONAL INFORMATION RELATED TO PERSONAL PROTECTIVE EQUIPMENT AND SAFETY PROTOCOLS.
TABLE 2
PARALLEL CONNECTION
To increase capacity, connect batteries in parallel. This will not increase
the system voltage.
Two 51.2V batteries rated at 30Ah connected in parallel
System Voltage: 51.2V
System Capacity: 30Ah + 30Ah = 60Ah
CALL TECH SUPPORT FOR ADDITIONAL CONFIGURATIONS
WARNING! SHOCK HAZARD; RISK OF FIRE – DO NOT INSTALL BATTERIES IN REVERSE POLARITY. THIS MAY PERMANENTLY DAMAGE THE BATTERY
WARNING! SHOCK HAZARD; RISK OF FIRE – DO NOT INSTALL BATTERIES IN SERIES. THIS MAY PERMANENTLY DAMAGE THE BATTERY
VENTILATION
Trojan® GC2 Series Lithium-Ion batteries do not release gas during normal use. There are no specific ventilation requirements for TR GC2 Series installations, although sufficient airflow should be provided to prevent excessive heat build-up.
BATTERY ENVIRONMENT
Batteries should be stored and installed in a clean, cool and dry place, keeping water, oil and dirt away from the batteries. If any of these materials are allowed to accumulate on the batteries, tracking and current leakage can occur, resulting in self-discharge and possible short-circuits. Battery chargers should also be installed in well-ventilated, clean areas that are easily accessible. Relative humidity should be <90%.
TEMPERATURE
The operating temperature range for discharging TR GC2 batteries is -4°F to
140°F (-20°C to 60°C). Charging batteries below 32°F (0°C) is prohibited, and
charging currents must be reduced below 68°F (20°C). See the product data
sheet for more information on charging current constraints.
Attempting to charge the battery at temperatures below 32ºF (0ºC) will cause
the battery to disconnect from the charger and enter an under-temperature
alarm, charging will be disabled while the alarm is active.
Refer to Section 10.1: “Charging” for charging current limitations.
Note that battery life diminishes as temperature increases, while capacity
diminishes as temperature decreases.
It is important to minimize temperature variations between the batteries.
Therefore, avoid restricting airflow by tightly packing batteries together.
The batteries should have a minimum of 0.50” (12.7mm) of space between them to
allow for adequate airflow.
BATTERY START-UP
Your battery may be shipped at 50% state of charge or lower.
Prior to installation, follow the instructions in Section 6.2: “Initial
Charging.”
To prevent imbalance between parallel batteries, when bringing batteries out
of storage mode, all batteries should be powered on within minutes of each
other. It is not recommended to leave a single battery in storage mode while
others in parallel are powered on unless instructed to do so for
troubleshooting purposes.
Perform the following steps to turn the battery on:
Verify that the battery is either completely disconnected or correctly connected to the equipment it will be powering.
-
Be sure that you are able to see the LEDs, then press and hold the status button.
-
The LEDs will successively turn on from left to right until they are all on.
-
Once all LEDs are on, wait another 2 seconds, then release the status button.
(Batteries with firmware 1.3 or higher will also blink all six LEDs to indicate the operation was successful) -
The battery will perform a self test for about 10 seconds and turn on. Press and release the status button to verify the green LED is on and the battery is ready to be used.
Perform the following steps to turn the battery off and place it in storage mode:
- Press and hold the status button.
- All LEDs will turn on, then successively turn off, starting with the green LED.
- Once all LEDs are off, wait another 2 seconds, then release the status button.
(Batteries with firmware 1.3 or higher will also blink all six LEDs to indicate the operation was successful)
If the battery has been intentionally turned off for shipping or because of a shutoff condition, you can restart it by the above steps. However, if a condition that causes a shutoff has not been corrected, the battery will shut off again. See Section 10.3: “Protection Limits: Automatic Safety Shutdown,” for specific explanations of shutdown causes.
INDICATOR LEDs
The Trojan® GC2 Lithium-Ion battery features a status push button and
indicator LEDs on the top of the case as illustrated below. After the status
button is momentarily pressed, the indicator LEDs will operate as follows:
LED COLOR | DEFINITION |
---|---|
Blue | Each blue LED represents 25% State of Charge (SOC) as shown in the |
legend. During charging, they will flash the SOC once each second.
Red| Active alarm (battery disabled)
Green| Battery OK
The light will display this color pattern while the button is pressed.
When the battery is charging, the blue LEDs will blink to indicate charging
and the increasing state of charge percentage. When the charging stops, all
the LEDs turn off.
CAN BUS
The battery includes a Controller Area Network (CAN) bus communications
interface. The two circular M8 DIN connectors are on the top of the battery to
enable one battery to connect to another battery using CAN bus cables in a
simple daisy chain wiring scheme. For normal battery operation, the CAN bus
feature is not required. The battery operates and protects autonomously; it
does not require any CAN bus communication or external devices such as
external controllers, or other CAN bus-connected batteries to function. Keep
the two black caps installed on the two M8 connectors to protect them from the
environment when not used. Trojan’s field service can retrieve the battery
usage history and view status over the CAN bus interface to help resolve
issues or questions. A certified field service technician can update the
battery firmware over the CAN bus to add features or enhancements. The CAN bus
interface is galvanically isolated from the internal battery voltages.
Therefore, an external power source is required to turn on and power the field
side of the isolated CAN bus. Contact Trojan’s technical support engineers if
you have any questions about the CAN bus interface and its use.
See Section 8: “Maximizing the Performance of Your Battery” for technical
support information.
PREVENTATIVE MAINTENANCE
INSPECTION
- Power off battery before inspection.
- Examine the outside appearance of the battery. The tops of the batteries and terminal connections should be clean, dry and free of corrosion.
- Check battery cables and connections. Replace any damaged cables and tighten any loose connections.
Refer to Section 4.2: “Terminals and Torque Values.”
CLEANING
Check the battery for cleanliness at regular intervals and keep terminals and
connectors free of corrosion.
Terminal corrosion may adversely affect the performance of the battery and
present a safety hazard.
-
Power off battery before cleaning.
-
Disconnect the battery from the charging source and the load.
-
Clean the top of the battery, terminals and connections with a damp cloth or non-metallic brush.
If the battery is extremely soiled, a household cleaner may be used. -
Dry with a clean cloth.
-
Keep the area around batteries clean and dry.
Charging
BACKGROUND
Trojan® GC2 Lithium-Ion batteries may be used in applications where lead-acid batteries have previously been utilized. Best charging results are obtained by using an appropriate Trojan-recommended charger and charging profile (algorithm). Refer to documentation on your specific charger for more information. Charging due to regenerative braking should also be reduced in environments below 68°F. Vehicles that use regenerative braking at cold temperatures may force the battery to shut off if too much current is applied back into the battery.
INITIAL CHARGING
Unless your dealer has charged your battery prior to delivery, it will be received at partial state of charge. If your system uses more than one battery, follow the steps below:
- Prior to installation, turn each battery on, then measure and record each battery’s voltage.
- If all voltages are within 0.5 volts of each other, turn them off, proceed with the installation, then follow the normal charging procedure.
- If the voltages differ by more than 0.5 volts, each battery should be individually charged, then the installation can proceed.
BALANCING
One function of a lithium-ion battery BMS is to maintain balance between each
group of cells within the battery.
This allows the battery to deliver full capacity without any cells
experiencing an over or under-voltage condition.
Balancing is performed when a parallel group of cells reaches a specified
threshold voltage corresponding to nearly 100% state of charge (SOC). At that
point, the highest-charged cells “bleed down” a small amount to enable the
remaining groups of cells to “catch up.”
INITIAL CHARGING CYCLES
In systems using more than one (1) battery, new batteries will be slightly unbalanced when they are unpacked and initially installed. Interruption of individual battery charging current and charge cycling may occur during the first charging cycle and is considered normal. Allow some extra time during first charging cycle to allow the batteries to come into balance.
Using a charger not designed for use with a lithium-ion battery may result in an imbalance between cells over time that requires charging maintenance to recover. Recovery of an imbalance condition requires one or more charging cycles to 100% state of charge using a lithium-ion specific charger or charging algorithm. Failure to do so may result in a battery lockout condition.
CHARGING PROFILES
Trojan GC2 Lithium-ion Series batteries should be charged using a lithium-ion
charging profile with a voltage setting matching the battery pack voltage as
shown in the table below. Use of a compatible charging profile is strongly
recommended to obtain a fully balanced battery pack. Using charging profiles
designed for lead-acid or other battery types may result in a sudden voltage
increase that will cause permanent damage to the battery BMS and render the
battery inoperative. For a list of compatible chargers and charging profiles,
visit www.trojanbattery.com.
Batteries regularly charged with equipment not optimized for lithium-ion
batteries may become imbalanced and is not recommended. See Section 6.3:
“Balancing” for additional information.
Use only With Compatible Lithium-Ion Chargers Scan For the Approved List
BATTERY VOLTAGE | RECOMMENDED CHARGER RANGE |
---|---|
24V | 27.36 – 28.0 |
36V | 41.0 – 42.0 |
48V | 54.7 – 56.0 |
Chargers which charge outside of the recommended range will result in battery faults and lead to slower charging, reduced performance or cell imbalance. Failure to fully charge the battery using the recommended charging profile may lead to reduced lifespan. See section 6.3 for additional information.
CHARGING AT TEMPERATURES BELOW 68°F (20°C)
Maximum charging currents must be reduced at temperatures below 68°F (20°C). Measures need to be taken to ensure that charging currents do not exceed the values shown on the product datasheet. As mentioned previously, charging is prohibited below 32°F (0°C). Charging due to regenerative braking should also be reduced in environments below 68ºF. Vehicles that use regenerative braking at cold temperatures may force the battery to shut off if too much current is applied back into the battery.
CHARGING PROCEDURE
- Verify that the battery is correctly hooked up to the charger with the positive wire on the positive (+) terminal and the negative wire on the negative (–) terminal.
- Ensure the charger is set to run the appropriate profile.
- If the charger will not run until it detects battery voltage, be sure that the batteries are turned on.
- Start charging, following the charger manufacturer’s instructions.
- After the charge has completed, the charger may be shut off and disconnected, or if it remains in a “maintenance mode” within the recommended charging range, it can remain connected to the battery indefinitely.
OTHER CHARGING INFORMATION
- Chargers which utilize an automatic desulfation or equalization mode are not recommended.
- While the battery is being charged, the blue LEDs will flash the current state of charge once each second. See Section 4.10: “Indicator LEDs,” for interpretation of LED information.
- If a battery shuts off due to low state of charge, it should be recharged as soon as possible. Failure to do so may render the battery permanently unusable.
- Depending upon the initial state of charge and the size of the load, even small quiescent loads such as motor controllers and on-board chargers can fully discharge batteries in as little as a few days. For instance, a 25mA load amounts to 0.6Ah discharge per day. Be sure to understand the quiescent loads in your application and set an appropriate charging interval. If the batteries will not be used for extended periods of time, turn them off.
- It is not recommended to use power outlets controlled by switches, peak shaving controllers or that rely solely on non-continuous power sources such as solar or wind generation to charge batteries. Interruption of the charge cycle may prevent the battery from reaching full state of charge or prolong charging times.
CHARGING FROM 0% STATE OF CHARGE
If the battery is discharged to 0% state of charge, voltage to the battery terminals will be disabled. This may interfere with the operation of battery chargers with voltage-sensing protection and prevent the charge cycle from starting. If the battery is at 0% state of charge and will not charge, use the following steps to recover the battery:
- Plug in the charger and connect it to the battery.
- Press the power button on the battery momentarily. If neither of the red or green status lights illuminate, the battery is in storage mode. If the battery is not in storage mode, it will need to be placed into storage mode using the procedure in section 4.9.
- Power on each battery following the procedure in section 4.9. All parallel connected batteries should be powered on as close to each other as possible.
- The charging cycle should begin within 1 minute of powering on the first battery. If it does not begin, verify power to the charger and the connection to the battery and repeat this process.
STORAGE AND SHIPPING
A fully charged TR GC2 can be safely stored in climate controlled conditions
for up to one year (12 months) while in sleep mode. It is recommended that the
battery state of charge is checked every 4-6 months. Temperatures exceeding
77ºF (25ºC) will cause the battery to self-discharge faster and will require
more frequent checks.
Never put the battery into prolonged storage if the state of charge is below
30%.
The following tips will help ensure that your batteries emerge from storage in good condition:
- Prior to long-term storage of the battery, fully charge the battery. Storing a discharged battery can result in permanent damage or decreased run time.
- Store in a cool and dry location, protected from the elements.
- Place the battery in storage mode to eliminate potential parasitic loads that may discharge the battery.
Perform the following steps to turn the battery off and place it in storage mode:
- Press and hold the status button for the entire sequence below.
- All LEDs will turn on, then successively turn off, starting with the green LED.
- Once all LEDs are off, release the status button after 2 more seconds.
- When batteries are taken out of storage they should be given an initial charge prior to use as outlined in Section 6.
IF YOU SHIP THIS BATTERY, YOU MUST COMPLY WITH STATE, FEDERAL AND INTERNATIONAL LAWS, RULES, REGULATIONS AND REQUIREMENTS REGARDING LITHIUM BATTERIES. YOU MUST UTILIZE A QUALIFIED SHIPPING AGENT PROPERLY CERTIFIED FOR HAZARDOUS MATERIALS (“HAZMAT”) SHIPMENTS.
MAXIMIZING THE PERFORMANCE OF YOUR BATTERY
- Follow all the procedures in this User’s Guide for proper installation, maintenance and storage.
- If you have any questions or concerns about battery care, please contact Trojan’s technical support engineers at 800-423-6569 Ext. 3045 or +1-562-236-3045 before a problem develops.
WHAT TO EXPECT FROM YOUR TROJAN LITHIUM-ION BATTERY
- Your Trojan® GC2 Series Lithium-Ion battery will deliver rated capacity when it is new. No “break-in” period is required.
- When operating batteries at low temperatures, they will deliver less than the rated capacity.
- When operating batteries at high temperatures, battery life will be reduced.
- The life of a battery is difficult to predict and will vary by application, frequency of usage and load characteristics.
QUIESCENT LOADS
Some vehicles, especially those with voltage reducers, radios and GPS units installed will continue to drain a small amount of power from the battery, even when with the key switch in the Off position or the vehicle placed in Tow Mode. This is called a quiescent load and can consume 5-10% of the battery’s capacity per day even when not in use. Quiescent loads will vary from vehicle to vehicle.
To limit these types of loads, it is important that all accessories are wired
through a switched power source that is disconnected with the vehicle’s key-
switch. If your vehicle has a quiescent load, after multiple days of
inactivity, the battery may have less than 100% state of charge, even if it
was plugged in prior to being stored.
For installations with a quiescent load, it is recommended that the battery is
disconnected from the vehicle or placed into storage mode before extended
periods of inactivity. To prevent over-discharge Trojan GC2 Series lithium-ion
batteries will enter storage mode after 4 days of inactivity and disconnect
itself from the vehicle. If the battery capacity drops below 25% while
inactive, it will enter storage mode in 7 hours. To wake the battery from
storage mode, simply press and hold the power button until all 6 LEDs have
illuminated, plus an additional 2 seconds. See Section 4.9 Battery Startup for
additional information.
ELECTRICAL SPECIFICATIONS
CHARGING
The charging and discharging current limits in the tables below are for one battery. Installing and electrically connecting batteries in parallel increases the current limits. For example, two batteries connected in parallel effectively doubles the current values in the tables below. Adding more batteries increases the driving range, current, and power capability.
CHARGING INFORMATION
Battery Voltage| 24V| 36V| 48V
Recommended Charging Voltage| 27.36 – 28.0V| 41.0 – 42.0V| 54.7 – 56.0V
Charge Voltage Cutoff| 29.12V| 43.68V| 58.4V
Peak Charge Current (max.)| 74A for 0.5 seconds| 74A for 0.5 seconds| 74A for
0.5 seconds
Charge Current (max. continuous) @ Temperature
< 32°F (0°C)| 0A| 0A| 0A
32°F to 50°F (0°C – 10°C)| 20A| 13A| 10A
50°F to 68°F (10°C – 20°C)| 34A| 23A| 17A
68°F to 113°F (20°C – 45°C)| 68A| 45A| 34A
113°F (45°C)| 0A| 0A| 0A
DISCHARGING
DISCHARGING INFORMATION
Battery Voltage| 24V| 36V| 48V
Discharge Current (max. continuous)| <90A| <60A| <45A
Discharge Current (time < 30 Seconds)| 150A| 133A| 100A
Discharge Current (time < 4 Seconds)| 155A| 155A| 155A
Discharge Current (time < 0.2 Seconds)| 174A| 174A| 174A
PROTECTION LIMITS: AUTOMATIC DISCONNECTION
As outlined in the following table, Trojan® GC2 Lithium-Ion batteries will automatically shut down under excessive use conditions in order to prevent damage to the battery and connected equipment. This will generally result in total loss of power to equipment. Systems must be implemented and precautions must be taken to ensure that sudden loss of power does not result in hazardous system behavior
AS NOTED IN SECTION 2: “SAFETY,” THE SYSTEM INSTALLER/USER ASSUMES ALL RESPONSIBILITY AND LIABILITY FOR ANY DAMAGES THAT MAY OCCUR DUE TO SUDDEN LOSS OF POWER.
PROTECTIVE SHUTOFF AND RESTART CONDITIONS
| SHUTOFF| RESTART| OTHER RESTART CONDITIONS
Over Voltage| Any cell voltage > 3.74V| 24V Battery Voltage>29.9V| All cell
voltages < 3.64V| 24V Battery Voltage>29.1V| Load attached and discharging
36V Battery Voltage>44.9V| 36V Battery Voltage>43.7V
48V Battery Voltage>59.9V| 48V Battery Voltage>58.2V
Low Voltage| Any cell voltage < 2.53V| 24V Battery Voltage>20.2V| All cell
voltages > 2.63V| 24V Battery Voltage>21.0V| Charger attached and charging
36V Battery Voltage>30.4V| 36V Battery Voltage>31.6V
48V Battery Voltage>40.5V| 48V Battery Voltage>42.1V
Short Circuit Current| 660A instantaneously| No automatic restart| Push and
hold the status button to clear red LED
Over Temperature Discharge| 140°F (60°C)| 131°F (55°C)|
Over Temperature Charge| 113°F (45°C)| 104°F (40°C)|
Under Temperature Discharge| -4°F (-20°C)| 14°F (-10°C)|
Under Temperature Charge| 32°F (0°C)| 41°F (5°C)|
Automatic Sleep/ Storage Mode| No use for 4 days or 7 hours if the battery
state of charge is lower than 25%| No automatic restart| Push and hold the
status button to manually wakeup the battery
BATTERY RECYCLING
Trojan® GC2 Lithium-Ion batteries are recyclable and should not be disposed of as household or landfill waste. If you need assistance in recycling your battery, contact your dealer or Trojan’s technical support engineers as outlined at the front of this manual.
BATTERY ABBREVIATIONS
A | Ampere | °F | Degrees Fahrenheit |
---|---|---|---|
Ah | Ampere-hour | M6/M8 | 6mm/8mm terminal |
AWG | American Wire Gauge | SOC | State of Charge |
BMS | Battery Management System | T | Temperature |
°C | Degrees Celsius | V | Volt |
DOD | Depth of Discharge | VDC | Volts DC |
TROJAN BATTERY COMPANY
would like to thank you for selecting our battery. With close to 100 years of experience, Trojan Battery is the world’s most trusted name in deep-cycle battery technology backed by our outstanding technical support. We look forward to serving your battery needs.
Do not mix with lead-acid batteries when recycling
FAILURE TO ABIDE BY THE CARE AND MAINTENANCE REQUIREMENTS OUTLINED HEREIN MAY RESULT IN VOIDING THE WARRANTY, AS APPLICABLE.
This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any means or in any form, without prior consent in writing from Trojan Battery Company, LLC. Trojan Battery Company and the Trojan Battery logo are registered trademarks of Trojan Battery Company.
© 2023 Trojan Battery Company, LLC. All rights reserved. Trojan Battery
Company is not liable for direct, indirect, special, exemplary, incidental or
consequential damages that may result from any information provided in or
omitted from this manual, under any circumstances. Trojan Battery Company
reserves the right to make adjustments to this manual at any time, without
notice or obligation.
12380 CLARK STREET, SANTA FE SPRINGS, CA 90670
TECHNICAL SUPPORT
800-423-6569 Ext. 3045 /
+1-562-236-3045
technical@trojanbattery.com
800.423.6569 +1.562.236.3000
TROJANBATTERY.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>