SINGLE UNIT INSTALLATION INSTRUCTIONS:

  1. Switch OFF the power before starting the installation.
  2. Fix the mounting brackets onto the ceiling using screws and an expansion plug (included). Refer to Table 1 for installation points.
  3. Mount the waterproof lamp onto the mounting brackets.
  4. Open the side clips of the waterproof fitting and diffuser as shown in the diagram.
  5. Fasten the waterproof connector clockwise and wire it into the terminal block.
  6. Install the diffuser and close the clips.
  7. Wire the waterproof fitting to the main power supply using a waterproof terminal block.
  8. Switch ON the power to test the light.

MULTIPLE (LINKABLE) UNITS INSTALLATION INSTRUCTIONS:

  1. Switch OFF the power before starting the installation.
  2. Fix the mounting brackets onto the ceiling using screws and an expansion plug. Refer to Table 1 for installation points.
  3. Mount the waterproof lamp onto the mounting brackets.
  4. Open the side clips of the waterproof fitting and diffuser as shown in the diagram.
  5. Wiring 1st waterproof fitting from both ends – Fasten the waterproof connector clockwise from one end and wire into the terminal block.

FAQ:

  • Q: What should I do if the light does not work after connecting power?
    A: Please check whether the light is properly connected to the mains power.

  • Q: How long should I charge the battery before using the emergency kit?
    A: Charge the battery for more than 36 hours before initial use.

  • Q: Can this product be used outdoors?
    A: Yes, this product can be installed both indoors and outdoors.

TECHNICAL DATA


MODEL

| ****

SKU

| ****

WATTS

| ****

LUMENS

| ****

CRI

| ****

DF

| BEAM ANGLE| ****

DIMENSION

| ****

INPUT POWER

| ****

L1

| MAX CONNECTABLE

UNITS

---|---|---|---|---|---|---|---|---|---|---
VT-120136E| 2120222,2120223| 36W| 4320LM| ≥80| ≥0.9| 120°| 1200x72x78mm| AC: 200-240V, 50/60Hz| 830+40mm| 10 UNITS
VT-150148E| 2120220,2120221| 48W| 5760LM| ≥80| ≥0.9| 120°| 1500x72x78mm| AC: 200-240V, 50/60Hz| 1090+40mm| 8 UNITS

EMERGENCY KIT

EMERGENCY POWER| BATTERY TYPE| CHARGING TIME| WORKING TIME| CHARGE RECHARGE| AMBIENT TEMPERATURE (ta)
---|---|---|---|---|---
6-7W| 9.6V 2200mAh Ni-Cd battery| 24 Hours| 3 Hours| 500 TIMES| 0-50°C

INTRODUCTION & WARRANTY

  • Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 3 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear.
  • The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of the product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

WARNING!

  1. Please make sure to turn o­ the power before starting the installation.
  2. Installation must be performed by a qualified electrician.
  3. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  4. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person to avoid a hazard.
  5. The luminaire is designed with an emergency kit with a replaceable battery. If the battery no longer meets their rated duration of operation after the corresponding recharge period the battery/emergency kit should be replaced by the manufacturer or his service agent or a similar qualified person to avoid a hazard.

NOTE : This Item can be Installed both Indoor and Outdoor

This marking indicates that this product should not be disposed of with other household wastes.
Caution, risk of electric shock.

CAUTION:

  1. The battery is in an empty state, please ensure to charge it more than 36 hours before using it.
  2. Power is connected but the light does not work, please check whether the light is properly connected to the mains.
  3. Please strictly use the emergency kit according to the wiring diagram before connection and pay attention to the reverse connection.

MULTILANGUAGE MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.

EMERGENCY WIRING DIAGRAM

V-TAC-VT-120136E-LED-Waterproof-Fitting-With-
Emergency-Kit-fig- \(3\)V-TAC-
VT-120136E-LED-Waterproof-Fitting-With-Emergency-Kit-fig-
\(4\)

IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU FOR MORE PRODUCT RANGES, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

SINGLE UNIT INSTALLATION INSTRUCTIONS

V-TAC-VT-120136E-LED-Waterproof-Fitting-With-Emergency-Kit-fig-
\(5\) V-TAC-VT-120136E-LED-
Waterproof-Fitting-With-Emergency-Kit-fig- \(6\)

  • STEP 1: Switch OFF the power before starting the installation.

  • STEP 2: Fix the mounting brackets onto the ceiling using screws and expansion plug(included).
    Please refer to Table 1 for installing the mounting bracket distance points.

  • STEP 3: Mount the waterproof lamp onto the mounting brackets

  • STEP 4: Open the side clips of the waterproof fitting and open the di­user as shown in the diagram.

  • STEP 5: Fasten the waterproof connector clockwise. Insert the cable through the waterproof connector and wire it into the terminal block.
    Note : For Maintained and Non-Maintained wiring please refer to the wiring diagram.

  • STEP 6: Install the di­user to the waterproof fitting and close the clips.

  • STEP 7: Wire the waterproof fitting to the main power supply. Ensure to use a waterproof terminal block [not included].

  • STEP 8: Switch ON the power to test the light.

MULTIPLE (LINKABLE) UNIT INSTALLATION INSTRUCTIONS

Note : Please refer to the model number and max linkable units which can be linked together. Based on the max linkable units select the max waterproof fittings that you would like to connectV-TAC-VT-120136E-LED-Waterproof-
Fitting-With-Emergency-Kit-fig- \(7\) V-TAC-VT-120136E-LED-Waterproof-Fitting-With-
Emergency-Kit-fig- \(8\)

  • STEP 1: Switch OFF the power before starting the installation.

  • STEP 2: Fix the mounting brackets onto the ceiling using screws and expansion plug(included).
    Please refer to Table 1 for installing the mounting bracket distance points.

  • STEP 3: Mount the waterproof lamp onto the mounting brackets.

  • STEP 4: Open the side clips of the waterproof fitting and open the di­user as shown in the diagram.

  • STEP 5: Wiring 1st waterproof fitting from both ends Fasten the waterproof connector clockwise from the first end insert the cable through the waterproof connector and wire into the terminal block from one end.
    Note : For Maintained and Non-Maintained wiring please refer to the wiring diagram.

  • STEP 6: Fasten the waterproof connector from the other end of the waterproof fitting and insert the wire into the terminal block. Using the same cable fasten the waterproof connector of the 2nd waterproof fitting and wire into the terminal block

  • STEP 7: Install the di­user to the waterproof fitting and close the clips.

  • STEP 8: Wire the waterproof fitting to the main power supply. Ensure to use a waterproof terminal block [not included].

  • STEP 9: Switch ON the power to test the light