profometer PM8500 Corrosion Kit User Guide
- May 15, 2024
- profometer
Table of Contents
PM8500
PM8500 Corrosion Kit
Quick Start Guide & Product Certificates
Profometer PM8500 – Standard Kit
A Carrying case|
---|---
B PM8500 Sensor|
C Universal Holder for Sensor|
D Chest harness for iPad|
E USB-C to USB-A cable|
F Battery charger + 2 AA batteries|
G 25-meter cable roll with clamp|
H REL100: Rod Electrode with spare parts|
I Copper sulphate, 250g|
J 1.5m Cable Rod – Sensor|
K Large sponge|
L Quick Start Guide|
Included
Profometer
WEL100: One Wheel Kit
A One wheel electrode with cables|
---|---
B Carbon fiber telescopic rod|
C Copper sulphate, 250g|
D Citric acid, 250g|
E Tool kit|
F Water container, 1.25l|
G Ball Joint for more flexible measurements|
Profometer WEL400 – Four Wheel Kit
A 150 to 250mm variable distance four-wheel electrode with cables|
---|---
B Carbon fiber telescopic rC Copper sulphate, 250g|
D Citric acid, 250g|
E Tool kit|
F Carrying case|
PM8500
Sensor
Battery charge and installation Use only rechargeable AA batteries in the
charger.
PM8500 Sensor
Connecting the rod electrodea. Connect the clamp of the ground cable (A)
with theexposed rebar
b Connect the ground cable (B) to the interface box using B1 plug
c. Connect the rod cable (C) to the interface box using C1 plug and to the
electrode using C2 plug PM8500 Sensor
Connecting the one wheel electrodea. Connect the clamp of the ground cable
(A) with the exposed rebar
b. Connect the ground cable (B) to the sensor using B1 plug
c. Connect the potential cable (C) and the encoder cable (D) to the sensor
using C1 and D1 plugs PM8500 Sensor
Connecting the four wheel electrodea. Connect the clamp of the ground cable
(A) with the exposed rebar
b.Connect the ground cable (B) to the sensor using B1 plug
c. Connect the potential cable (C) and the encoder cable (D) to the sensor
using C1 and D1 plugs PM8500 Rod Electrode
Filling the rod electrode with Copper Sulphate Remove the cap with the wooden
plug and soak it into water for about an hour to allow the wood to saturate
and swell.
Prepare the saturated solution by mixing 40 units by weight of copper sulphate
with 100 units by weight of distilled water.
Add an additional teaspoon of copper sulphate crystals into the electrode.
The electrode should be filled as completely as possible with a minimum of air
in the compartment.
PM8500 Wheel Electrodes
Filling the wheel electrodes with Copper Sulphatea. The wooden plug (A) is not intended to be removed. Immerse
the wheel in water for an hour to allow the water to soak into the plug.
b. Only the wheels should be immersed, therefore, please remove them from the
legs before doing it.
The felt hoops (B) and the felt hoop connector must be saturated before
measuring. In normal use (with water and cupper solution), the thin felt is on
the wooden spigot side (A).
c. Prepare the saturated solution by mixing 40 units by weight of copper
sulphate with 100 units by weight of distilled water. Fill in the cupper tank
removing the plug (C). Add an additional teaspoon of copper sulphate crystals
into the electrode.
The electrode should be filled as completely as possible with a minimum of air
in the compartment.
d. Fill in the water container with water. To do so you need to remove the
water plug (D).
e. The water should be dripping out slowly from the water tank throughout the
1mm nozzle (E). The bike valve on the opposite side should provide a high
pressure; if water is dripping out too fast, please apply some pressure
blowing the bike valve with your mouth.
PM8500 Universal holder
How to mount the interface box on the harness a. Use the inner clamp (A)
of the universal holder to attach it to the iPad harness or your belt
PM8500 Universal holder
How to mount the interface box on the telescopic rod a. Connect the round
support (B) of the universal holder to the telescopic rod and attach it using
the rubber band (C).
b. Recommendation: Use the holder rubber band as strain relief for the cable-
reel-cable.
PM8500 Telescopic rod
How to mount the telescopic rod on the one wheel and four wheel
electrodea. Connect the telescopic rod with the one
wheel / four-wheel connector (A)
b. Move the indented wheel clockwise to join both parts
PM8500 Accessory: Ball Joint for one Wheel electrode
How to mount the ball joint on the telescopic rod and on the one wheel
electrodea. Connect the telescopic rod with the
ball joint accessory by rotating the indented ring clockwise (A)
b.Connect the one-wheel electrode with the ball joint accessory by rotating
the indented ring clockwise (B)
c. Use the ball adjuster (C) to move freely your one-wheel electrode position
in a range of 360º. Please be aware of the position of the cables and the
sensor unit.
PM8500 Accessory: Ball Joint for one Wheel electrode
How to mount the ball joint on the telescopic rod and on the one wheel
electrode PM8500 Rod Electrode Foams
How to replace the foam of the rod electrodea. Remove the foam (A) from the rod
electrode if it is broken or overused
b. Stick the new foam (B) into the same position. Please use only a small amount of glue
PM8500 Four wheel variable distance
How to change the distance between the wheels (limited from 150mm to 250mm)a. Unscrew the collars (A) – wheels 2, 3 and 4. Wheel 1 is always fixed
b. Slide the wheel legs (B) to the desired position
c. For the 150mm version, mount the wheels as described in the position marks (C) (all wheels are facing to the fixed wheel)
d. For the 250mm version, mount the wheels as described in the position marks (D) (the right two wheels must be turned to face the right side)
e. Screw the collars (A) to fix the wheels at the desired position
f. Any other distance from 150mm to 250mm can be selectedPM8500 Four wheel variable distance
How to change the distance between the wheels (limited from 150mm to 250mm)PM8500 Four wheel variable distance
How to change the distance between the wheels (limited from 150mm to 250mm)PM8500 Start device
Turning on / off the deviceMedium press (3 sec) LED: Green solid
https://www.screeningeagle.com/en/products/profometer- pm8500
For product usage information, please refer to the Profometer PM8500
documentation.
It is available for download on: www.screeningeagle.com/en/products
/profometer-pm8500
PM8500 Using the Profometer App
Download the app
Download the app “Profometer” on the Apple® App Store
https://apps.apple.com/app/profometer/id1638693429
For product usage information, please refer to the Profometer PM8500
documentation.
It is available for download on: www.screeningeagle.com/en/products
/profometer-pm8500
PM8500 Using the Profometer App
Create your accountPM8500 Using the Profometer App
Create your account PM8500 Using the Profometer App
Create your account PM8500 Using the Profometer App
Connect to the sensor PM8500 Using the Profometer App
Create new measurement
UK Declaration of Conformity
Products | Profometer PM8500 |
---|---|
Proceq Part Numbers | 392 21 000 |
Manufacturer | Procegq SA, Ringstrasse 2 8603 Schwerzenbach, Switzerland |
The object of the declaration described above is in conformity with relevant
statutory requirements and designated standards:
Electrical Equipment (Safety) Regulations 2016
S.1. 2016:1101
EN 61010-1:2010
Safety requirements for electrical equipment for measurement, control, and
laboratory use – Part 1: General requirements
Electromagnetic Compatibility Regulations 2016
S.1. 2016:1091
EN 61000-6-1:2007
Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity
for residential, commercial and light-industrial environments
Radio Equipment Regulations 2017 Wideband transmission
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
S.1. 2017:1206
EN ETSI! 300 328 V2.2.2
S.1. 2012: 2032
Waste Electrical and Electronic Equipment Regulations 2013 (as amended)
S.I. 2013:3113
Patrick Waller
Declaration of Conformity
Products | Profometer PM8500 |
---|---|
Proceq Part Numbers | 39260200 |
Manufacturer | Proceg SA, Ringstrasse 2 8603 Schwerzenbach, Switzerland |
We confirm that the product named above is in conformity with RoHS, WEEE and
the following directives and standards:
Low voltage directive
Safety requirements, General requirements
EMC directive
EMC Part 6-1: Immunity commercial and light-indu:
Radio Equipment directive
Wideband transmission
RoHS directive
WEEE directive
2014/35/EU
EN/IEC 61010-1
2014/30/EU
EN 61000-6-1
2014/53/EU
EN ETSI 300 328 V2.2.2
2011/65/EU & 2015/863/EU
2012/19/EU
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. This Class B
digital apparatus complies with Industry Canada RSS standards. To comply with
FCC and Industry Canada RF radiation exposure limits for general population,
the transmitter with its antenna must be installed such that a minimum
separation distance of 20 cm is always maintained between the radiator
{antenna) and all persons and must not be collocated or operating in
conjunction with any other antenna or transmitter.
Schwerzenbach, 29.Aug.2023 Patrick Waller Swiss Made Declaration
Products: | Profometer PM8500 |
---|---|
Proceq Part Numbers: | 39260200 |
Manufacturer: | Proceq SA, Ringstrasse 28603 Schwerzenbach, Switzerland |
We confirm that the products named above were developed and manufactured in
Switzerland and fulfill the requirements needed for the declaration “Made in
Switzerland” or “Swiss Made”.
The requirements for industrial products are specified in detail in the
National Swiss Trademark Protection Statute (Art. 47-60, MSchG) covering goods
and services.
Schwerzenbach, 22.9.2023 Patrick Waller
Chief Operating Officer
Notice
This document (incl. Quick Start Guide and Product Certificates) constitutes
an integral part of Proceq’s General Terms and Conditions of Sale and General
Terms and Conditions of Rental, together with any other guideline,
precautions, policies and conditions which Proceq has made and may make
available to you at
www.proceq.com/downloads, as amended from
time to time (the Documents). Proceq reserves the right to change without
notice any information, specifications and recommendations contained in this
document and in any of the associated Documents.
You shall observe and be solely responsible for the safe and lawful use of and
your own conduct while using this product, and any consequences thereof. The
use and operation of this product is at your own discretion and risk. Proceq
hereby disclaims any and all loss, liability or damages resulting from or out
of your use of the product. Please ensure you operate and use this product
only for purposes that are proper and in accordance with the instructions
given herein together with all safety and health precautions, applicable laws,
rules, regulations, and as provided for in any of the Documents.
The English version of the content remains the official version.
All translated content should bear an appropriate notice to this effect.
For safety and liability information, please download at
www.screeningeagle.com/safety-and-liability Subject to change. Copyright © 2024 by Proceq SA,
Schwerzenbach. All rights reserved.
ASIA-PACIFIC
Screening Eagle Singapore Pte. Ltd.
1 Fusionopolis Way
Connexis South Tower #20-03
Singapore 138632
T +65 6331 4151| EUROPE
Screening Eagle Technologies AG
Ringstrasse 2
8603 Schwerzenbach, Zurich
Switzerland
T +41 43 355 38 00| USA, CANADA & CENTRAL AMERICA
Screening Eagle USA Inc.
4001 West Parmer Lane Suite 125
Austin, TX 78727 United States
T +1 724 512 0330
---|---|---
CHINA
Proceq Trading Shanghai Co. Ltd.
Part of Screening Eagle
Room 701, 7th Floor, Golden Block
407-1 Yishan Road, Xuhui District
200030 Shanghai
China T +86 21 6317 7479| UK
Screening Eagle UK Limited
The Bradfield Centre
184 Cambridge Science Park Road
CB4 0GA, Cambridge
United Kingdom
T +44 1223 981905| Screening Eagle USA Inc.
117 Corporation Drive
Aliquippa, PA 15001
United States
T +1 724 512 0330
| MIDDLE EAST AND AFRICA
Proceq Middle East and Africa
Part of Screening Eagle
Sharjah Airport International
Free Zone, P.O.Box: 8365
United Arab Emirates
T +971 6 5578505| SOUTH AMERICA
Proceq SAO Equipamentos de
Mediçao Ltda.
Part of Screening Eagle
Rua Paes Leme, 136, cj 610
Pinheiros, Sao Paulo
SP 05424-010
Brasil T +55 11 3083 3889
82039205 I 09.2023
ScreeningEagle.com
References
- Screening Eagle Technologies - Protect The Built World - Protect The Built World
- Download - Protect The Built World
- Profometer PM8500
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>