Yale YDM7220 Digital Door Lock
External Body
(External Body, installation on the outside of the door)
Basic Contents
- User Manual
- Installation Guide
- RFID Key Tags X 4
- Mechanical Keys X 2
- Screws
Optional Accessories
- Remote Controller
- Remote Control Module
- Bluetooth Module
- AA Batteries X 4
Specifications
Parts | Specifications | Remarks |
---|---|---|
External Body | 68(W) X 335(H) X 26.S(D) mm | Operating temperature |
-15~55°C(5~131 °F)
Internal Body| 72(W) X 344(H) X 36(0) mm
Works for| 4x 1.5VAA Alkaline batteries(Operatingvoltage:4.5~6V)
Optional product| Remotecontroller,Moduleand etc.
- Battery life may vary depending on temperature, moisture levels, frequency of use and the quality of battery used. Estimated battery life expectancy of 1 year (lock is used 10 times per day).
- Optional products may not be available depending on your country or local dealer.
Internal Body
(Internal Body, installation on the inside of the door)
External Body
1 | Keypad(10-key) |
---|---|
2 | Dead Bolt Jam Indicator |
3 | Lever |
4 | Fingerprint Sensor |
5 | RFID Key Tag Reader |
6 | Low Battery Indicator |
7 | Emergency key cover |
8 | Emergency Mechanical Key Slot (Inside) |
9 | Emergency Power Supply Terminal |
Internal Body
1 | Battery Cover |
---|---|
2 | Module Accessory Slot (Optional) |
3 | @ Registration button |
4 | Lever |
5 | Safe Handle Button |
6 | Manual Thumb Turn |
7 | Internal Forced Lock Switch |
8 | 1.5V AA Alkaline Batteries ( 4PCS) |
9 | Auto/Manual Lock Button |
10 | Volume Control Switch |
11 | Mortise Lock |
12 | Latch Bolt |
13 | Automatic Locking Sensor |
14 | Dead Bolt |
Setting Menu
- Normal Mode: Anyone who knows ‘User PIN Code’ has authority to set features.
- Advanced Mode: Only the person who knows ‘Advanced PIN Code’ has authority to set features.
- Visitor Code: Users with Visitor Code can only open the door with no access to change settings.
- Onetime Code : The onetime code is used only once for unlocking the door lock and automatically deleted after usage.
- User Slot Number: It should be 2 digits(like ’01 ‘, ’02’ . .’99’, ’00’) and available in advanced mode.
Product Features
-
One Touch Fingerprint Access
Fingerprint detection for personalised access. Unique Sensor not only provides high security but faster unlocking experience as well. -
Smart Touchpad -Auto Lock
The door Locks when you touch the palm on the keypad. -
3 minute Lock Out Feature
After five(S) unsuccessful attempts at entering an invalid code or RFI D Key Tags, 3minute Lock out mode will be activated. -
Smart Etiquette
When entering a pin code on the keypad, the user can open the door lock in silent mode. -
Fake PIN Code
Users can hide their pin code by either entering a series of digits at the beginning or after their pin code. thus, the pin code is not exposed. -
Internal Forced Lock
It is a security-enhancing function that ‘disables’ authentication methods such as passwords, RFI D key tags and fingerprints from outside when setting up functions indoors. -
External Forced Lock
It is a security-enhancing function that an alarm goes off if someone opens door from inside when setting up functions outside. -
Voice Guidance
It guides you through the operation status on how to enable various features & settings- mode for easier and more convenient use. -
Safe Handle
This feature can help prevent small children exiting the home without permission ..
Otherfeatures and Benefits
Remote Controller (Optional):
- This option may not be available depending on your country or local dealer.
- Network Module/Controller (Optional):
- It allows door lock to connect with Home network controller.
- Intrusion/Broken Alarm.
- Low Battery Alarm and Emergency Power Supply.
- Yale Network Module.
Yale Access App
Yale Access gives you the peace of mind of knowing who and what you love is
safe – no matter where you are- just at the touch of your smartphone.
Normal Mode
(Default Mode)
Normal mode is for convenient mode for anyone with user code to change
various settings.
Remote Control Registration
Set with registration button located on the top of remote controller. You can
press it using a pin like the one shown in the image.
Please note following when pairing lock with Yale Access App.
- Because Yale Access App is only available in advanced mode.
- Please be informed that all registered credentials will be deleted when changing mode or registering and deleting app.
- Depending on product type or Firmware version, app registration and door lock connection in normal mode may not be possible, so if registration is not possible, change from normal mode to advanced mode and try again.
Automatic/Manual Lock
Enable Automatic Lock
- Release the button to set automatic lock mode on the internal Body M (after opening the battery cover).
Enable Manual Lock
- Press the button to set manual lock mode on the internal Body.
Unlocking Door with Fake Code
External Forced Lock
Enable External Forced Lock : Fingerprint
- Scan with registered Fingerprint and hold the fingerprint area 11!!,J until you hear 3 beep sounds.
Enable External Forced Lock: User Code
Enable External Forced Lock: RFI D Key Tag
Contact RFI D key tag on [RFI D key tag reader] for 5 sec. until you hear 3 beeps.
Disable External Forced Lock
To disable the External Forced lock enter the pin code, present a registered
card or unlock the door using fingerprint.
If the internal Lever is turned to open the door from inside, the alarm will
sound.
Volume
The operation sound volume will be adjusted according to the Volume Switch setting.
Minute Lock Out
All access mode from the external side are disabled for 3 minutes to deter
unauthorized access.
Disable 3-minute Lock Out
- Open with inside door bar.
- Open the door with mechanical key.
- Press I button.
Alarm
Intrusion Alarm : The alarm goes off when someone forces the door open.
For example, In case of an intrusion by opening a gap in the door while the
door is locked.
Broken Alarm(Breakage Alarm) : The alarm goes off when the front part is
Broken Alarm(Breakage Alarm) : The alarm goes off when the front part is
Turn off alarm
- Enter the registered User code.
- Press I button for 5 seconds.
- Enter the registered Fingerprint.
- Touch the registered RFID Key Tag.
Emergency power supply for discharged batteries
Power supply
It may sustain 1 year if used 10 times a day. (Users are advised to use I authentic Alkaline batteries.)* Kindly dispose of used batteries.
You must replace all 4 batteries in the following cases:
- The Low Battery LED on the keypad flickers red.
- When a low battery notification message is played.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE NATIONAL CODE OR RECYCLING PROGRAM.
Warning
USE ONLY ALKALINE BATTERIES
DO NOT USE LITHIUM OR RECHARGEABLE BATTERIES BECAUSE THEY MAY CAUSE THE LOCK
TO MALFUNCTION
Code Chart
Duplicate if necessary
PIN Code Management(Up to 100 Users.)
User Type| User Name| PIN Code
Advanced| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
User| |
Please be informed that all registered credentials will be deleted when changing mode or registering and deleting app.
Advanced Mode
Advanced mode is a mode in which only the administrator can set the door lock
and provide access to other users.100 users passwords, 100 users RFID key
tags, 100 users fingerprint and individual registration and deletion of one-
time passwords enable efficient management of visitors.
User Slot Number should be 2 digits. like ’01’ … ’99’ and ’00’: Location of
100th user slot must be assigned “00” instead of “100”.
1 Avoid to set up sequenced numbers e.g. 1,2,3,4)
3 If you have previously setup PIN codes, Fingerprints or Key tags to the
lock, the registration of Yale Access Module will erase them all but the
Master Pin Code. They must be registered again via Yale Access app.
Important notes
Safety and Warning
- For use on residential entry doors. Not to be used where the internal escutcheon will be exposed to outdoor elements (e.g. on a gate).
- Do not attempt to disassemble the digital door lock by yourself.
- By doing so, you may get an electric shock and damage the product.
- Do not use force with a tool onto the product.
- Make sure to lock the door tight when you go out.
- Be careful not to hit the handle as it may cause injuries.
- Do not use water and any type of solvent to clean the product such as gasoline or benzene as they can cause damage to electronic circuit, deterioration and or paint peel-off.
- It is recommended to change User Code on a regular basis.
- In manual lock mode, make sure to double check whether the door is securely locked.
- When External Forced lock is set and unlock the door, the alarm will be activated.
- Do not use lithium or rechargeable bameries.
- Only alkaline batteries are recommended.
- Make sure to follow the above instructions to avoid any injuries.
- It cannot be guaranteed in special conditions & environment such as water condensation, seaside.
- Warranty will not cover- exposure to dampness, excessive heat, excessive humidity and other extreme environmental conditions, corrosion, damage beyond repair, rusting, unauthorised modifications, unauthorised repairs, neglect, accident, alteration, natual disaster, spillage of liquid or food particles.
PLEASE READ INSTRUCTIONS BEFORE USE.
The functions and design of this product can be changed without prior notice
for performance and quality improvement.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>