FEIT Electric UCL36FP Flat Under Cabinet Light Installation Guide

June 7, 2024
Feit Electric

FEIT LOGO 2

Mode I: UCL36FP/5CCTCA
FLAT-PANEL UNDER CABINET LIGHT
FITS 36 IN. CABINETS (32 1/2 IN. TOTAL LENGTH)
IMPORTANT SAFETY INSTRUCTIONS
AND INSTALLATION GUIDE

FEIT Electric UCL36FP Flat Under Cabinet Light - PARTS

READ BEFORE INSTALLATION
SAVE THESE INSTRUCTIONS

Questions, problems, missing parts? Before returning to the store,
call Feit Electric Customer Service
8 a.m. – 5 p.m., PST, Monday – Friday
1-866-326-BULB (2852)
FEIT.COM

We appreciate the trust and confidence you have placed in Feit Electric through the purchase of this Under Cabinet Light. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Feit Electric.

Safety Information

IMPORTANT SAFEGUARDS:
ALWAYS FOLLOW BASIC SAFETY PRECAUTIONS WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT.

Save These Instructions

CAUTION: Do not install this fixture inside a totally enclosed cabinet. Do not mount over stoves.

WARNING : To avoid the risk of electrical shock, always make sure the product is unplugged from the electrical outlet before assembling, disassembling, relocating, servicing or cleaning it.
CAUTION : Do not install this product in a wet location.
CAUTION : Do not install this product in an outdoor location.
CAUTION : Do not use chemical solvents or harsh abrasives to clean the fixture.
Supplier’s Declaration of Conformity : 47 CFR § 2.1077 Compliance Information

Responsible Party: Feit Electric Company
4901 Gregg Road, Pico Rivera, CA 90660, USA
562-463-2852
Unique Identifier: UCL24FP/5CCTCAG2

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. CAN ICES-005(B).

Limited Warranty

This product is warranted to be free from defects in workmanship and materials for up to 5 years from the date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact- us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Pre- Assembly

TOOLS REQUIRED

FEIT Electric UCL36FP Flat Under Cabinet Light - PARTS

HARDWARE INCLUDED

NOTE : Hardware not shown to actual size.

FEIT Electric UCL24FP OneSync Flat Panel Under Cabinet Light -
hardware

Part Description Quantity
AA 36 in. LED Flat Panel Fixture 1
BB 18 in. Linking Cable 1
CC Mounting Screws 2
DD Fixture Mounting Template 1
EE Hardwire Bracket 1
FF Hardwire Bracket Screw 1
GG Wire Nut 3
HH Clamp Connector 1
II 18 AWG Wire (Green Ground Wire) 1
Rem No. Description Volts (V)
Per Fixture (W) Input
Current (mA) Maximum Linkable
Units at 120V Maximum Linkable

Units with
In-Wall Dimmer
---|---|---|---|---|---|---
UCL36FP/5CCTCAGA| 24 Inch Flat Panel
Under Cabinet LED Fixture| 120| 28| 240| 30| 5

LIGHTING DISTRIBUTION

Distance Center Beam (Foot Candles) Beam Diameter

3 ft
5 ft
8 ft
15ft| 96
34
13.5
3.8| 7.2 ft
12 ft
19 ft
36 ft

Beam Spread:100º  CD@CB:   861

Single LED Fixture Hardwire Installation I

  1. Turn Off the Power
    Turn the power OFF from the breaker panel before starting installation.FEIT
Electric UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
1

  2. Position the Fixture
    Find the desired place for the LED light fixture and mark dearly using the provided mounting bracket template (DD).FEIT Electric UCL24FP OneSync Flat
Panel Under Cabinet Light - Plug not included 1

  3. Installing the Mounting Screws
    Screw-in the Mounting Screws (CC) on the marked locations, leaving a gap of 0.08-0.10 inches between the screw head and the installation surface.FEIT
Electric UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
3

  4. Removing the Hardwire Bracket
    Bracket Remove the screw on the hardwire bracket, then slide and lift the bracket off of the fixture.FEIT Electric UCL24FP OneSync Flat Panel Under
Cabinet Light - Installation 4

  5. Removing the Knock-out
    Carefully remove the knock-out with a flathead screwdriver.FEIT Electric
UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
5

  6. Installing the Clamp Connector to the Knockout Hole
    Hole Install the Clamp Connector (HH) to the knock-out hole by inserting it through the hole and securing it with the nut The Clamp Connector (HH) should be on the outer side of the bracket.FEIT Electric UCL24FP OneSync Flat Panel
Under Cabinet Light - Installation 6

  7. Cutting and Stripping Wires
    Take out of the black and white 18 AWG wires in the fixture CC and the green 18 AWG wire (IQ in the plastic bag. Cut and strip the wires to the correct length.FEIT Electric UCL24FP OneSync Flat Panel Under Cabinet Light -
Installation 7

Single LED Fixture Hardware Installation (continued)

  1. Wire Power Supply to the Fixture
    Feed the supply wire through the Clamp Connector (HH) and knockout hole and make all connections using the wire nuts provided. Connect the 120V line (black) wire to the black wire. Connect the neutral (white) wire to the white wire. Connect the ground (green) wire to the green wire.FEIT Electric
UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
8

  2. Replace the Wiring Bracket
    After connecting the wires correctly, place the wires inside the fixture and reinsert the bracket, sliding it over and screwing it securely.FEIT Electric
UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
9

  3. Secure Supply Wires with the Clamp Connector
    Connector Secure the supply wire by firmly screwing the clamp connectors down on the wire.FEIT Electric UCL24FP OneSync Flat Panel Under Cabinet Light -
Installation 10

  4. Installing LED Fixture
    Align holes on the back of the fixture to the heads of the Mounting Screws. Slide fixture towards the mounting slot If the fixture is not snug, remove the fixture and readjust the screws.FEIT Electric UCL24FP OneSync Flat Panel
Under Cabinet Light - Installation 11

  5. Linking LED Fixtures
    Connect the LED Fixtures (AA) using the provided Linking Cable (BB).FEIT
Electric UCL24FP OneSync Flat Panel Under Cabinet Light - Installation
12
    **NOTE** : To install 2 or more LED fixtures, repeat the single fixture installation instructions with two or more units.

Alternative Plug-In Installation (Electrical Plug not Included)

  1. Position the Fixtures
    Find the desired place for the LED light fixture and mark clearly using the provided mounting bracket template (DD).FEIT Electric UCL24FP OneSync Flat
Panel Under Cabinet Light - Plug not included 1

  2. Installing the Mounting Screws
    Screws Screw in the Mounting Screws (CC) on the marked locations, leaving a gap of 0.08-0.10 inches between the screw head and the installation surface.FEIT Electric UCL24FP OneSync Flat Panel Under Cabinet Light - Plug
not included 2

  3. Installing LED Fixture
    Align holes on the back of the fixture to the heads of the Mounting Screws. Slide fixture forwards to secure into place. If the fixture is not snug, remove the fixture and readjust the screws.FEIT Electric UCL24FP OneSync
Flat Panel Under Cabinet Light - Plug not included 3

  4. Connecting the Power Supply
    Plug-In Electrical Plug to the LED Fixture (AA).FEIT Electric UCL24FP
OneSync Flat Panel Under Cabinet Light - Plug not included
4
    NOTE: The °teethesl plug can be connected to either side of the LED Fixture (AA).

  5. Connecting to a Power
    Outlet Connect the Electrical Plug to the power outlet on the wall.FEIT
Electric UCL24FP OneSync Flat Panel Under Cabinet Light - Plug not included
5

Operating Instructions

FEIT Electric UCL24FP OneSync Flat Panel Under Cabinet Light -
operating

Use the ON/OFF and Dim Button for ON/OFF Operation and to Change the Dimming Levels

  • To select the desired dimming level, cycle through the dimming levels (High, Medium, Low, Dim, Off) by pressing the Dim Button. This setting will be fixed each time the ON/OFF switch is turned ON.

Changing the Color Temperature Setting

  • To select the desired color temperature, cycle through 2700K – 3000K – 3500K – 4000K – 5000K by pressing the CCT Button. This setting will be fixed each time the ON/OFF switch is turned ON.

This LED Fixture has the feature to operate and control multiple units, even if they are not linked.

  • To control multiple fixtures, Hold the CCT button for 3 seconds on all the fixtures to be controlled in a group.
  • To remove the individual fixture from the group, Hold the CCT button on the fixture that you want to control individually for 3 seconds.

WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>