MITSUBISHI ELECTRIC PKA-A24KA7 Wall Mounted Heat Pump System Owner’s Manual
- June 17, 2024
- Mitsubishi Electric
Table of Contents
PKA-A24KA7 & PUZ-A24NHA7
24,000 BTU/H WALL-MOUNTED INDOOR UNIT
24,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR
Job Name:
System Reference: Date:
Indoor Unit ……………………….. PKA-A24KA7
Outdoor Unit …………………. PUZ-A24NHA7
INDOOR UNIT FEATURES
- Sleek, compact design
- Simple installation
- Vane setting for air flow direction control
- Auto fan speed mode
- Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Pre-charged with refrigerant volume for piping length up to 70 ft
- Low ambient cooling down to 0°F providing 100% capacity
- 24-hour continuous operation (cooling mode)
- High pressure protection
- Fast restart
- Superior energy and operational efficiency
- Seacoast protection*
- External Outer Panel: Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
- Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
- Heat exchanger coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
*Seacoast protection standard from 2022 production
SPECIFICATIONS: PKA-A24KA7 & PUZ-A24NHA7
Cooling at 95°F1| Maximum Capacity|
BTU/H
|
24,000
---|---|---|---
Rated Capacity|
BTU/H
|
24,000
Minimum Capacity|
BTU/H
|
10,000
Maximum Power Input|
W
|
1,960
Rated Power Input|
W
|
1,960
Moisture Removal|
Pints/h
|
5.0
Sensible Heat Factor| |
0.77
Power Factor [208V / 230V]|
%
|
95.7 / 95.7
Heating at 47°F2| Maximum Capacity|
BTU/H
|
28,000
Rated Capacity|
BTU/H
|
26,000
Minimum Capacity|
BTU/H
|
9,000
Maximum Power Input|
W
|
2,600
Rated Power Input|
W
|
1,750
Power Factor [208V / 230V]|
%
|
750.0 / 750.0
Heating at 17°F3| Maximum Capacity|
BTU/H
|
18,300
Rated Capacity|
BTU/H
|
15,700
Maximum Power Input|
W
|
1,820
Rated Power Input|
W
|
1,750
Heating at 5°F4| Maximum Capacity|
BTU/H
|
15,200
Maximum Power Input|
W
|
2,300
Efficiency| SEER | SEER2| |
21.4 | 21.3
EER1 | EER21| |
12.2 | 12.2
HSPF [IV] | HSPF2 [IV]| |
11.0 | 9.3
COP at 47°F2| |
4.35
COP at 17°F at Maximum Capacity3| |
2.95
COP at 5°F at Maximum Capacity4| |
1.94
ENERGY STAR® Certified| |
No
Electrical| Voltage, Phase, Frequency| |
208/230, 1, 60
Guaranteed Voltage Range|
V AC
|
198 – 253
Voltage: Indoor – Outdoor, S1-S2|
V AC
|
208/230
Voltage: Indoor – Outdoor, S2-S3|
V DC
|
24
Short-circuit Current Rating [SCCR]|
kA
|
5
Recommended Fuse/Breaker Size (Outdoor)|
A
|
25
Recommended Wire Size [Indoor – Outdoor]|
AWG
|
14
Power Supply| |
Indoor unit is powered by the outdoor unit
Indoor Unit| MCA|
A
|
1.0
Fan Motor Full Load Amperage|
A
|
0.36
Fan Motor Type| |
DC Motor
Airflow Rate at Cooling, Dry|
CFM
|
635–705–775
Airflow Rate at Cooling, Wet|
CFM
|
570–635–700
Airflow Rate at Heating, Dry|
CFM
|
635–705–775
Sound Pressure Level [Cooling]|
dB[A]
|
39–42–45
Sound Pressure Level [Heating]|
dB[A]
|
39–42–45
Drain Pipe Size|
In. [mm]
|
5/8 [16]
Coating on Heat Exchanger| |
—
External Finish Color| |
White Munsell 1.0Y 9.2/0.2
Unit Dimensions|
W x D x H: In. [mm]
|
46-1/16 x 11-5/8 x 14-3/8 [1,170 x 295 x 365]
Package Dimensions|
W x D x H: In. [mm]
|
51 x 14-1/4 x 18-1/2 [1,295 x 362 x 470]
Unit Weight|
Lbs. [kg]
|
46 [21]
Package Weight|
Lbs. [kg]
|
53 [24]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*|
°F
|
90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]|
°F
|
77 DB / 59 DB
Outdoor Unit| MCA|
A
|
19.0
MOCP|
A
|
26
Fan Motor Full Load Amperage|
A
|
0.4
Fan Motor Output|
W
|
86
Airflow Rate [Cooling / Heating]|
CFM
|
1940 / 1940
Refrigerant Control| |
LEV
Defrost Method| |
Reverse Cycle
Coating on Heat Exchanger| |
Blue Fin Coating***
Sound Pressure Level, Cooling1|
dB(A)
|
47
Sound Pressure Level, Heating2|
dB(A)
|
48
Compressor Type| |
INVERTER-driven twin rotary
Compressor Model| |
SNB172FWHM1
Compressor Rated Load Amps|
A
|
7
Compressor Locked Rotor Amps|
A
|
11.0
Compressor Oil [Type // Charge]|
oz.
|
FV50S // 23
External Finish Color| |
Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| |
N/A
Unit Dimensions|
W x D x H: In. [mm]
|
37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943]
Package Dimensions|
W x D x H: In. [mm]
|
40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033]
Unit Weight|
Lbs. [kg]
|
153 [69]
Package Weight|
Lbs. [kg]
|
179 [81]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]*|
°F
|
115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]|
°F
|
70 DB, 59 WB / -4 DB, -4 WB
Heating Thermal Lock-out / Re-start Temperatures**|
°F
|
-8 / -4
Refrigerant| Type| |
R410A
Pre-Charged Refrigerant Amount|
Lbs, oz
|
7.0, 11.0
Maximum Pre-Charged Piping Length|
Ft. [m]
|
70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length|
oz./Ft. [g/m]
|
0.7 [50]
Piping| Gas Pipe Size O.D. [Flared]|
In.[mm]
|
5/8 [15.88]
Liquid Pipe Size O.D. [Flared]|
In.[mm]
|
3/8 [9.52]
Maximum Piping Length|
Ft. [m]
|
165 [50]
Maximum Height Difference|
Ft. [m]
|
100 [30]
Maximum Number of Bends| |
15
NOTES:
AHRI Rated Conditions
(Rated data is determined at a fixed compressor speed)
1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
2 Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3 Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
» Wind baffles required to operate below 23°F DB in cooling mode.
» Heat pump system with wind baffle: 0°F – 115°F.
» Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
***Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****
INDOOR UNIT ACCESSORIES: PKA-A24KA7
Control Interface | 3-Pin Connector | PAC-715AD |
---|---|---|
BACnet® and Modbus® Interface | PAC-UKPRC001-CN-1 | |
IT Extender | PAC-WHS01IE-E | |
kumo station® for kumo cloud® | TAC-WHS01HC-E | |
Thermostat Interface | PAC-US444CN-1 | |
Thermostat Interface | PAC-US445CN-1 | |
USNAP Adapter | PAC-WHS01UP-E | |
Wireless Interface for kumo cloud® | PAC-USWHS002-WF-2 | |
Remote Sensor | Flush Mount Remote Temperature Sensor | PAC-USSEN002-FM-1 |
Flush Mount Temperature Sensor | PAC-USSEN001-FM-1 | |
Remote Temperature Sensor | PAC-SE41TS-E | |
Wireless temperature and humitity sensor for kumo cloud® | PAC-USWHS003-TH-1 | |
Wired Remote Controller | Deluxe Wired MA Remote Controller† | AAR-40MAAU |
Simple Ductless Wired Remote Controller | PAC-SDW01RC-1 | |
Simple MA Remote Controller† | PAC-YT53CRAU-J | |
Touch MA Controller† | PAR-CT01MAU-SB | |
Wireless Remote Controller | kumo touch™ RedLINK™ Wireless Controller | MHK2 |
Lockdown bracket for remote controller | RCMKP1CB | |
Wireless MA Receiver | PAR-SR32MA-E | |
Wireless MA Remote Controller | PAR-FL32MA-E | |
Condensate | Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor | |
(208/230V) [recommended] | X87-721 | |
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor |
X87-835
Drain Pan Level Sensor/Control| SS610E
Refco Condensate Pump (100-240 VAC)| GOBI-II
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| TAZ-
MS303
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)|
MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-65
OUTDOOR UNIT ACCESSORIES: PUZ-A24NHA7
Air Outlet Guide | Air Outlet Guide (1 Piece) | PAC-SG59SG-E |
---|---|---|
Centralized Drain Pan | Centralized Drain Pan | PAC-SG63DP-E |
Drain Pan | PAC-SG64DP-E | |
Control/Service Tool | Control/Service Tool | PAC-SK52ST |
M- & P-Series Maintenance Tool Cable Set | M21EC0397 | |
USB/UART Conversion Cable (Required for all laptop connection) | M21EC1397 | |
Hail Guards | Hail Guard | HG-A6 |
M-NET Converter | M-NET Converter | PAC-SJ85MA-E |
M-NET Converter | PAC-SJ95MA-E | |
Mini-Split Wire | 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll | S144-250 |
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll | S144-50 | |
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll | S164-250 | |
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll | S164-50 | |
Mounting Pad | Condensing Unit Mounting Pad: 24” x 42” x 3” | ULTRILITE2 |
Stand | 18” Single Fan Stand | QSMS1801M |
24” Single Fan Stand | QSMS2401M | |
Condenser Wall Bracket | QSWB2000M-1 | |
Condenser Wall Bracket – Stainless Steel Finish | QSWBSS | |
Outdoor Unit Stand — 12” High | QSMS1201M | |
Wind Baffle | Front Wind Baffle | WB-PA5 |
Rear Wind Baffle | WB-RE5 | |
Side Advanced Wind Baffle | WB-SD5 |
INDOOR UNIT DIMENSIONS: PKA-A24KA7
Unit: inch (mm)
Top side
Left side
- Knockout hole for left piping
Front side
- Operation lamp
- DEFROST/STAND BY lamp
- Receiver
Right side
- Mount board
- Knockout hole for right piping
Front side(Grille open)
- Terminal block for Outdoor unit
- Terminal block for power supply (option)
- Terminal block for MA-remote controller
- Emergency operation switch (cooling/heating)
- 17-15/32(444)Gas pipe
- 18-31/32(482)Liquid pipe
- Drain hose
- Filter hook
Piping connection
1 Liquid pipe| Refrigerant pipe: 3/8 O.D([ 9.52)
Flared connection: 3/8F
---|---
2 Gas pipe| Refrigerant pipe: 5/8 O.D([ 15.88)
Flared connection: 5/8F
3 Drain hose| 5/8([ 16) O.D
Effective length: 23-1/32 (585)
Under side
- Vane(auto)
- Louver(manual)
- Knockout hole for lower piping
Sleeve
(purchased locally)| Through hole
---|---
[2-15/16] (75)| [ 2-15/16~[ 3-5/32] (75~[ 80)
Required space(Indoor unit)
- Air inlet
- Air outlet
Knockout hole for piping
-
4- 11/32 Bolt hole
-
Center measurement hole
3/32 -
Mount board
-
Indoor unit outline
-
Wall hole for right rear piping
-
Knockout hole for rear piping
-
75- 3/16
Tapping screw hole
OUTDOOR UNIT DIMENSIONS: PUZ-A24NHA7
1 FREE SPACE (Around the unit)
The diagram below shows a basic example.
Explanation of particular details are given in the installation manuals etc.
2 SERVICE SPACE
Dimensions of space needed for service access are shown in the below diagram.
3 FOUNDATION BOLTS
Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be purchased locally.)
- FOUNDATION
4 PIPING-WIRING DIRECTIONS
Piping and wiring connections can be made from 4 directions:
FRONT, Right, Rear and Below.
Unit: mm
- Rear Air Intake
- 2-U Shaped notched holes (Foundation Bolt M10<W3/8>)
- Installation Feet
- 2-12×36 oval holes (Foundation Bolt M10<W3/8>)
- Air Discharge
- Side Air Intake
Example of Notes
(1) … Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)
(2) … Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F)
*1… Indication of STOP VALVE connection location.
-
Air Intake
-
Handle for moving
-
Rear Air Intake
-
Side Air Intake
-
Earth terminal
-
Terminal Connections
Left … Power supply wiring
Right … Indoor/Outdoor wiring -
Service panel
-
Front piping cover
-
Rear piping cover
Piping knockout Hole Details
- Front piping hole (knockout)
- Front trunking hole (knockout)
- Power supply wiring hole (2-ø27knockout)
- Right piping hole (knockout)
- Right trunking hole (knockout)
- Power supply wiring hole (2- ø27<1-1/16>knockout)
- Rear trunking hole (knockout)
- Rear piping hole (knockout)
Set the attachment to the When installing the conduit, inner side of each panel.
- 1/2 Conduit attachment
- Bottom piping hole (knockout)
- Drain hole (5- ø33<1-5/16>)
FORM# PKA-A24KA7 & PUZ-A24NHA7 – 202304
Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.