MITSUBISHI ELECTRIC PUZ-A36NKA7 Wall Mounted Heat Pump System Owner’s Manual
- June 17, 2024
- Mitsubishi Electric
Table of Contents
MITSUBISHI ELECTRIC PUZ-A36NKA7 Wall Mounted Heat Pump System
Product Usage Instructions
Indoor Unit Installation
- Locate a suitable wall for mounting the indoor unit.
- Ensure proper electrical connections are in place.
- Mount the indoor unit securely using appropriate hardware.
- Connect refrigerant piping as per manufacturer guidelines.
- Install any required accessories such as control interfaces or sensors.
Outdoor Unit Installation
- Select a level outdoor location for installation.
- Place the outdoor unit on a stable platform or mounting pad.
- Connect the outdoor unit to the indoor unit using refrigerant piping.
- Ensure proper electrical connections are made.
- Install any necessary accessories like wind baffles or mounting stands.
FAQ
- Q: Can I install the indoor unit without professional help?
- A: It is recommended to hire a professional HVAC technician for the installation of both indoor and outdoor units to ensure proper setup and performance.
- Q: What is the recommended maintenance schedule for this product?
- A: Regular maintenance, including cleaning filters, checking refrigerant levels, and inspecting for any leaks, should be performed at least once a year to keep the units running efficiently.
- Q: How do I troubleshoot if the unit is not cooling/heating properly?
- A: Check the air filters for blockages, ensure proper airflow around the units, and verify that all settings are correct on the control interface. If issues persist, contact a qualified technician for further diagnosis.
INDOOR UNIT FEATURES
- Sleek, compact design
- Simple installation
- Vane setting for airflow direction control
- Auto fan speed mode
- Ideal for spaces such as server rooms, daycare centres, classrooms, churches, small offices, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Pre-charged with refrigerant volume for piping length up to 100 ft
- Low ambient cooling down to 0°F providing 100% capacity
- 24-hour continuous operation (cooling mode)
- High-pressure protection
- Fast restart
- Superior energy and operational efficiency
- Seacoast protection*
- External Outer Panel: Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
- Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
- Heat exchanger coil and base panel rated for 2,000 hours under ASTM B117 testing
- Seacoast protection standard from 2022 production
SPECIFICATIONS
SPECIFICATIONS: PKA-A36KA7 & PUZ-A36NKA7
Cooling at 95°F1
| Maximum Capacity| BTU/H| 36,000
---|---|---|---
Rated Capacity| BTU/H| 36,000
Minimum Capacity| BTU/H| 16,000
Maximum Power Input| W| 3,330
Rated Power Input| W| 3,330
Moisture Removal| Pints/h| 9.7
Sensible Heat Factor| 0.70
Power Factor [208V / 230V]| %| 96.5 / 96.5
Heating at 47°F2
| Maximum Capacity| BTU/H| 40,000
Rated Capacity| BTU/H| 38,000
Minimum Capacity| BTU/H| 18,200
Maximum Power Input| W| 3,700
Rated Power Input| W| 2,460
Power Factor [208V / 230V]| %| 610.0 / 610.0
Heating at 17°F3
| Maximum Capacity| BTU/H| 25,900
Rated Capacity| BTU/H| 22,400
Maximum Power Input| W| 2,670
Rated Power Input| W| 2,610
Efficiency
| SEER | SEER2| 18.8 | 19.4
EER1 | EER21| 10.8 | 10.8
HSPF [IV] | HSPF2 [IV]| 9.2 | 8.4
COP at 47°F2| 4.52
COP at 17°F at Maximum Capacity3| 2.85
ENERGY STAR® Certified| No
Electrical
| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 30
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| The indoor unit is powered by the outdoor unit
Indoor Unit
| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.57
Fan Motor Type| DC Motor
Airflow Rate at Cooling, Dry| CFM| 705–810–920
Airflow Rate at Cooling, Wet| CFM| 635–730–830
Airflow Rate at Heating, Dry| CFM| 705–810–920
Sound Pressure Level [Cooling]| dB[A]| 43–46–49
Sound Pressure Level [Heating]| dB[A]| 43–46–49
Drain Pipe Size| In. [mm]| 5/8 [16]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 1.0Y 9.2/0.2
Unit Dimensions| W x D x H: In. [mm]| 46-1/16 x 11-5/8 x 14-3/8 [1,170 x 295 x
365]
Package Dimensions| W x D x H: In. [mm]| 51 x 14-1/4 x 18-1/2 [1,295 x 362 x
470]
Unit Weight| Lbs. [kg]| 46 [21]
Package Weight| Lbs. [kg]| 53 [24]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum /
Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 77 DB / 59 DB
NOTES
AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB,
75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F
(Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor
// Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles are required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
- Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
- Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****
SPECIFICATIONS: PKA-A36KA7 & PUZ-A36NKA7
Outdoor Unit
| MCA| A| 25.0
---|---|---|---
MOCP| A| 31
Fan Motor Full Load Amperage| A| 0.5 + 0.5
Fan Motor Output| W| 74
Airflow Rate [Cooling / Heating]| CFM| 3880 / 3880
Refrigerant Control| LEV
Defrost Method| Reverse Cycle
Coating on Heat Exchanger| Blue Fin Coating***
Sound Pressure Level, Cooling1| dB(A)| 52
Sound Pressure Level, Heating2| dB(A)| 53
Compressor Type| INVERTER-driven twin rotary
Compressor Model| MNB33FBRMC-L
Compressor Rated Load Amps| A| 8
Compressor Rotor Amps| A| 13.0
Compressor Oil [Type // Charge]| oz.| FV50S // 45
External Finish Color| Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| N/A
Unit Dimensions| W x D x H: In. [mm]| 41-5/16 x 13 (+1-3/16) x 52-11/16 [1050
x 330 (+30) x 1338]
Package Dimensions| W x D x H: In. [mm]| 42-15/16 x 17-11/16 x 56-4/16 [1091 x
450 x 1429]
Unit Weight| Lbs. [kg]| 214 [97]
Package Weight| Lbs. [kg]| 245 [111]
Outdoor Unit Operating Temperature Range
| Cooling Air Temp [Maximum / Minimum]*| °F| 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]| °F| 70 DB, 59 WB / -4 DB, -4 WB
Heating Thermal Lock-out / Re-start Temperatures**| °F| -8 / -4
Refrigerant
| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 10.0, 6.0
Maximum Pre-Charged Piping Length| Ft. [m]| 100.0 [30.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.7
[50]
Piping
| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Maximum Piping Length| Ft. [m]| 165 [50]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15
NOTES
AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB,
75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F
(Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor
// Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
- Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles are required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
- Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
- Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****
INDOOR UNIT ACCESSORIES: PKA-A36KA7
Control Interface
| 3-Pin Connector| PAC-715AD
---|---|---
BACnet® and Modbus® Interface| PAC-UKPRC001-CN-1
IT Extender| PAC-WHS01IE-E
Kumo station® for kumo cloud®| TAC-WHS01HC-E
Thermostat Interface| PAC-US444CN-1
Thermostat Interface| PAC-US445CN-1
USNAP Adapter| PAC-WHS01UP-E
Wireless Interface for Kumo cloud®| PAC-USWHS002-WF-2
Remote Sensor
| Flush Mount Remote Temperature Sensor| PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| PAC-USSEN001-FM-1
Remote Temperature Sensor| PAC-SE41TS-E
Wireless temperature and humidity sensor for Kumo cloud®| PAC-USWHS003-TH-1
Wired Remote Controller
| Deluxe Wired MA Remote Controller†| AAR-40MAAU
Simple Ductless Wired Remote Controller| PAC-SDW01RC-1
Simple MA Remote Controller†| PAC-YT53CRAU-J
Touch MA Controller†| PAR-CT01MAU-SB
Wireless Remote Controller
| Kumo touch™ RedLINK™ Wireless Controller| MHK2
Lockdown bracket for remote controller| RCMKP1CB
Wireless MA Receiver| PAR-SR32MA-E
Wireless MA Remote Controller| PAR-FL32MA-E
Condensate
| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended]| X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor|
X87-835
Drain Pan Level Sensor/Control| SS610E
Refco Condensate Pump (100-240 VAC)| GOBI-II
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| TAZ-MS303
Lineset
| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-65
OUTDOOR UNIT ACCESSORIES: PUZ-A36NKA7
Air Outlet Guide| Air Outlet Guide (1 Piece)| □ PAC-SH96SG-E (two pieces are
required)
---|---|---
Control/Service Tool
| Control/Service Tool| □ PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set| □| M21EC0397
USB/UART Conversion Cable (Required for all laptop connections)| □| M21EC1397
M-NET Converter
| M-NET Converter| □ PAC-SJ85MA-E
M-NET Converter| □ PAC-SJ95MA-E
Mini-Split Wire
| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □| S144-250
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □| S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □| S164-250
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □| S164-50
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2
Stand
| 18” Dual Fan Stand| □ QSMS1802M
24” Dual Fan Stand| □ QSMS2402M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1202M
Wind Baffle
| Front Wind Baffle| □ WB-PA3 (two pieces are required)
Rear Wind Baffle| □ WB-RE6
Side Advanced Wind Baffle| □ WB-SD6
DIMENSIONS
INDOOR UNIT DIMENSIONS: PKA-A36KA7
OUTDOOR UNIT DIMENSIONS: PUZ-A36NKA7
FORM# PKA-A36KA7 & PUZ-A36NKA7 – 202304 Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.