hysen HYT001 WIFI Digital Heating Thermostat User Manual

June 17, 2024
HYSEN

hysen HYT001 WIFI Digital Heating Thermostat

hysen HYT001 WIFI Digital Heating Thermostat

Important Information

Many thanks for your selection of our products and services, and also for your trust and support to us.

Search for “Smart life” from google play or App store to Download the WIFI App.

| Turn on the thermostat—-press —choose “General”—fill in “123456”—choose “No” to “Yes” in “network connect “ item. then you can start connect WIFI.
---|---

Features

(A) High resolution TFT IPS 480*480 screen
(B) 0.5°C accuracy keeps temperature within the level you set. (C) Children lock to prevent misoperation by children
(D) Data memory when power is off. (E) Holiday mode make you enjoy more comfortable temperature in holiday
(F) The temperature of external sensor can be checked

Product Specifications

  • Power: 90-240Vac 50/60Hz ☆ Display accuracy::0.5°C
  • Probe sensor::NTC(10k)1%
  • Contact capacity::3A/(WW);16A/(WE)
  • Limit temperature range::1~70°C
  • Range of temperature adjustment::5~35°C
  • Range of temperature display:1~70°C
  • Insulating condition: Normal environment
  • Running program: Set per 1 week as a cycle ☆ Output: Switch relay
  • Installation: recessed type (in the wall)
  • Size(mm):868615mm

Description of icon

Programming mode Manual mode
Temporary manual mode Child lock
 Holiday mode, Holiday days and temperature can be set to run in countdown mode Heating,, icon disappears to stop heating Clock
Activate window function return to last menu
 Fault alarm (the specific alarm cause can be inquired on the “Information” page)

N O symbols represent
A Turn ON/OFF: Short press to turn on/ turn off
B
  1. Short press to reduce temp
  2. in program mode ,short press to switch temporary manual mode
  3. Long press to unlock

C| ****|

  1. Short press to increase temp
  2. in program mode ,short press to switch temporary manual mode

D| | Short press to enter “information/General /Advanced /Programming” setting.

Information –General –Advanced—Programming Parameters you should fill in password (123456) when you enter them each time.( you can change it in advanced option Return difference: limit valve of external sensor is 45℃ for factory default (A6),value of external sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will remind high temperature production alarm. If temperature decline to 43℃relay continue to work and heating alarm will be relieved. (it can be operated ,only when room temperature is lower than setting temperature ) Sensor fault display: please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown),sensor error will be displayed on the screen. Thermostat will stop heating until the fault is eliminated
Warranty:
We offer the warranty of 24 months, from the sales day. The products of our company can have life time warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for theater -sale service

Wiring Diagram

Wiring Diagram

Note: In WW products ,if the valve has not been switched on for 100hours,thevalve will be forced open for 3minutes

Information

Item Parameter (can’t change
Current temperature
External temperature (option)
Current humidity (option)
Local temperature (option)
Local humidity (option)
Heating hours of the week Open load time this week
Heating hour this month Open load time this month
Total heating hour Open load total time since thermostat is

working
Network Status|
Alarm fault type|

General

Item Parameter default
Setting time Year-month-day-week-hour-minute
Screen brightness 1-9 9
Standby screen Screen on/ off off
Lock Yes/ no No
Mode setting Manual, programming , holiday manual
Network connect Yes/ No No
Language selection English/German/Spanish/Polish/Italian

English

Advanced

Item Parameter Default
Temperature compensation -9~+9 -1

Start temperature

hysteresis

| 0.5~2.5| 1
External sensor protection| 1~9| 2
temperature hysteresis| |
---|---|---
High temperature protection value| 20-70| 45
Low temperature protection  value| 1-10| 5
Set the upper temperature limit| 20-70| 35
Set the lower temperature limit| 1-10| 5
Password setting| | 123456
Child lock| Half lock ,full lock| Half lock
Sensor type| Built in /external /internal

and external

| Built in
Window opening setting time| 1-60 min| 10
Window opening setting temperature| 10-20| 10
Holiday mode time| 1-30 days| 1
Holiday mode temperature| 5-35| 15
Reset| Yes/No| No
Heating time clear| Yes/No| No

Programming parameters

Item Parameter default
Programming type 5+2/6+1/7 days 5+2

Default of programming parameter

section period Temperature (default)
Section 1 06:00-08:00 20
Section 2 08:00-11:30 15
Section 3 11:30-12:30 15
Section 4 12:30-17:30 15
Section 5 17:30-22:00 20
Section 6 22:00-06:00 15

Documents / Resources

| hysen HYT001 WIFI Digital Heating Thermostat [pdf] User Manual
HYT001 WIFI Digital Heating Thermostat, HYT001, WIFI Digital Heating Thermostat, Digital Heating Thermostat, Heating Thermostat
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYSEN User Manuals

Related Manuals