HYSEN HY369 TRV Thermostatic Zigbee Radiator Valve User Manual
- June 17, 2024
- HYSEN
Table of Contents
HYSEN HY369 TRV Thermostatic Zigbee Radiator Valve User Manual
INSTALLATION INSTRUCTION
Search for ” Smart RM or Smart life ” Download the Wifi App with the following
icon.| After the Zigbee gateway is configured, enter the gateway to add sub-
devices. At the same time, you need to wait for the actuator to be powered on
and the system self-check is completed, long press the combination key“ ” and
“ ELECTRICAL SHOCK
Please arrange professional technician to install the product according to
drawings and instructions. Disconnect power supply before making any
connection. Contact with components carrying hazardous ” Activate l Please
refer to the gateway manual for Zigbee gateway configuration
---|---
| First time open thermostat, it displays all icons for 3s
---|---
****| Time setting: whenflashing,then press enter hour setting ,press
or to adjust value,press again enter minute setting,press or
to adjust value,press again to set week,press or to adjust
value,press to confirm setting and remember time.
Note: after the actuator completes its self-check,under normal working status,if need to modify time, long press 3s access to advanced settings. And press to
choose , short press enter time setting. the same as above method.
| When display “ADA”, press Start system self-check, when display “1”, this
is the first step of system self-check.
****| When Display “2”, this is the second step for self-check.As shown in
the picture, it is the second step of the system self-check. After the self-
check is completed, if there is no fault prompt, it will enter the normal
working state. If there is a fault prompt, please handle the
fault first, otherwise it will not enter the normal working state.
Er1| Motor fault
Er2| Sensor fault
****| Flashing show low battery
ower: 3AA 1.5V alkaline batteries
Working temperature::0-50°C
Display accuracy::0.5℃
Default range of temperature adjustment:5~35°C
Probe sensor::NTC(10k)1%
Range of temperature display::0~70°C
Thread size:M301.5
Size(mm):6652*100mm
Maximum route:4.5mm
Displays & Buttons
| Explain
---|---
A| Auto mode 6 times periods, Low battery icon , Child lock
B| Energy saving mode , Comfort mode
C| Holiday mode,Manual mode,Auto mode,BOOST mode,
Advanced Options
D| Clock , Auto mode setting , Set temperature
E| Room temperature, Valve status , Open window function
F **| 1. Short press to switch Auto mode and Manual mode2. Long
press enter to advanced settings
G **| 1. Decreasing Key2. Long press to activate force close
valve (display【OFF】)
H ****| 1. Short press to switch Comfort mode and Energy
saving mode2. Long press for 3s to switch set temperature of Energy saving
mode or Comfort mode , press or to adjust value
I| 1. Increasing Key2. Long press to activate force open valve
(display OP)
J ****| 1. Long press 3 seconds to start the BOOST
function: turn on the BOOST fast heating mode, short press any key during
operation to exit this function and return to the previous working mode2.
When setting other functions, short press is the confirmation key3. Long
press for 3 seconds to lock/unlock keys
Technical Data
Holiday mode| press 3s access to advanced setting, short press to
choose holiday mode ,then short press enter temperature setting,
again short press setting days setting,press or to adjust value. Under
holiday mode, short press to exit holiday mode.
---|---
Open Windows Function ****| 1. The actuator turns
off the window opening function by default, if you need to use it, you can
turn it on in the advanced option A2 setting [reset disable when changing the
battery]2. When the actuator detects that the indoor temperature drops
quickly to the valve closed setting value (adjustment range: 5℃-25℃), the
valve will be closed for 15 minutes (adjustment range: 5-60 minutes), and it
will be closed after the window opening function is completed. Return to the
previous working mode,but the valve will be fully opened.
Function
Auto mode parameter setting
Long press about 3s access to advanced setting, short press switch to auto
mode setting , short press access to auto mode setting, short press to choose
which item you want, First set the auto mode to 5 means :5=5+2 days, 6 = 6+1
days, 7 = 7 days, after press to access
to hour or minute setting, short press access to temperature setting. Press or
to adjust value. short press choose: hour,minute, time period, and press or to
adjust data, finished setting, about 10 seconds will automatic save and exist
Period | Default Period | Default temperature |
---|---|---|
1 | AM06:00—AM08:00 | 20℃ |
2 | AM08:00—AM11:30 | 15℃ |
3 | AM11:30—PM12:30 | 15℃ |
4 | PM12:30—PM05:30 | 15℃ |
5 | PM05:30—PM10:00 | 20℃ |
6 | PM10:00—AM06:00 | 15℃ |
Advanced Options
Press about 3-5s to access to advanced setting, short press until flashing, press to access to advanced options, press or to adjust value, after finish setting every time, short press or to set next option, after finishing all , don’t operate, after 10s it will automatically save and exit.
NO | Set up items | Setting parameters | Default |
---|---|---|---|
A1 | Measuring temperaturecorrection | -9-+9℃(Displayed as the corrected room | |
temperature value) | -1℃ |
A2
| Open window function parameter: temperature and running time| 1: display
means disable open window function,press key display 5°C means this
function enable(temperature setting range: 5-25°C)2: Running
time:5-60min(after enable function,press change setting)|
A3| Automatic lock if nooperation more than 10 minutes| 0:Disable 1: Enable| 0
A4| Setting temperature minimum limit| 1-15°C| 5℃
A5| Setting temperaturemaximum limit| 16-70°C| 35℃
A6| BOOST moderunning time| 100s-900s , Steps of 100 seconds| 300
A7
|
View valve open status
| 0-100100 mean valve open 100%5 mean valve open 5%|
A8
| Start/stop workingtemperature difference setting| 0.5-1.5|
1
A9| Control type of valve| 0: PID 1: Float 2:ON/OFF| 0
AA| Reset| When display 88, press or change the value to00, press
to restore the factory settings, and the screen will be fully displayed for 2
seconds.|
AB| Valve Seal Type| 0:Soft Seal 1:Hard Seal| 0
AC| Descaling function| 0: Disable descaling function1: Enable descaling
function| 1
RISK OF ELECTRICAL SHOCK
Please arrange professional technician to install the product according to
drawings and instructions. Disconnect power supply before making any
connection. Contact with components carryinghazardous
Read User Manual Online (PDF format)