HYSEN HY369 TRV Thermostatic Zigbee Radiator Valve User Manual

June 17, 2024
HYSEN

HYSEN HY369 TRV Thermostatic Zigbee Radiator Valve User Manual

INSTALLATION INSTRUCTION

Search for ” Smart RM or Smart life ” Download the Wifi App with the following icon.| After the Zigbee gateway is configured, enter the gateway to add sub- devices. At the same time, you need to wait for the actuator to be powered on and the system self-check is completed, long press the combination key“ ” and “ ELECTRICAL SHOCK
Please arrange professional technician to install the product according to drawings and instructions. Disconnect power supply before making any connection. Contact with components carrying hazardous ” Activate l Please refer to the gateway manual for Zigbee gateway configuration
---|---
| First time open thermostat, it displays all icons for 3s
---|---
****| Time setting: whenflashing,then press     enter hour setting ,press or    to adjust value,press      again enter minute setting,press      or to adjust value,press     again to set week,press    or      to adjust value,press     to confirm setting and remember time.

Note: after the actuator completes its self-check,under normal working status,if need to modify time, long press   3s access to advanced settings. And press to

choose   , short press enter time setting. the same as above method.

| When display “ADA”, press   Start system self-check, when display “1”, this is the first step of system self-check.
****| When Display “2”, this is the second step for self-check.As shown in the picture, it is the second step of the system self-check. After the self- check is completed, if there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the

fault first, otherwise it will not enter the normal working state.

Er1| Motor fault
Er2| Sensor fault
****| Flashing show low battery

ower: 3AA 1.5V alkaline batteries
Working temperature::0-50°C
Display accuracy::0.5℃
Default range of temperature adjustment:5~35°C
Probe sensor::NTC(10k)1%
Range of temperature display::0~70°C
Thread size:M301.5
Size(mm):66
52*100mm
Maximum route:4.5mm

Displays & Buttons

| Explain
---|---
A| Auto mode 6 times periods,  Low battery icon ,   Child lock
B| Energy saving mode , Comfort mode
C| Holiday mode,Manual mode,Auto mode,BOOST mode, Advanced Options
D| Clock , Auto mode setting ,          Set temperature
E| Room temperature, Valve status , Open window function
F **| 1.   Short press to switch Auto mode and Manual mode2.   Long press enter to advanced settings
G **| 1.      Decreasing Key2.      Long press to activate force close valve (display【OFF】)
H ****| 1.   Short press to switch Comfort mode and Energy saving mode2.   Long press for 3s to switch set temperature of Energy saving mode or Comfort mode , press or   to adjust value
I| 1.   Increasing Key2.   Long press to activate force open valve (display OP)
J ****| 1.   Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode2. When setting other functions, short press is the confirmation key3.   Long press for 3 seconds to lock/unlock keys

Technical Data

Holiday mode| press      3s access to advanced setting, short press  to choose holiday mode    ,then short press       enter temperature setting, again short press  setting days setting,press     or to adjust value. Under holiday mode, short press  to exit holiday mode.
---|---
Open Windows Function ****| 1.  The actuator turns off the window opening function by default, if you need to use it, you can turn it on in the advanced option A2 setting [reset disable when changing the battery]2.  When the actuator detects that the indoor temperature drops quickly to the valve closed setting value (adjustment range: 5℃-25℃), the valve will be closed for 15 minutes (adjustment range: 5-60 minutes), and it will be closed after the window opening function is completed. Return to the previous working mode,but the valve will be fully opened.

Function

view

Auto mode parameter setting
Long press about 3s access to advanced setting, short press switch to auto mode setting , short press access to auto mode setting, short press to choose which item you want, First set the auto mode to 5 means :5=5+2 days, 6 = 6+1 days, 7 = 7 days, after press to access
to hour or minute setting, short press access to temperature setting. Press or to adjust value. short press choose: hour,minute, time period, and press or to adjust data, finished setting, about 10 seconds will automatic save and exist

Period Default Period Default temperature
1 AM06:00—AM08:00 20℃
2 AM08:00—AM11:30 15℃
3 AM11:30—PM12:30 15℃
4 PM12:30—PM05:30 15℃
5 PM05:30—PM10:00 20℃
6 PM10:00—AM06:00 15℃

Advanced Options

Press about 3-5s to access to advanced setting, short press until flashing, press to access to advanced options, press or to adjust value, after finish setting every time, short press or to set next option, after finishing all , don’t operate, after 10s it will automatically save and exit.

NO Set up items Setting parameters Default
A1 Measuring temperaturecorrection -9-+9℃(Displayed as the corrected room
temperature value) -1℃

A2

| Open window function parameter: temperature and running time| 1: display means disable open window function,press    key display 5°C means this function enable(temperature setting range: 5-25°C)2: Running time:5-60min(after enable function,press   change setting)|
A3| Automatic lock if nooperation more than 10 minutes| 0:Disable 1: Enable| 0
A4| Setting temperature minimum limit| 1-15°C| 5℃
A5| Setting temperaturemaximum limit| 16-70°C| 35℃
A6| BOOST moderunning time| 100s-900s , Steps of 100 seconds| 300

A7

|

View valve open status

| 0-100100 mean valve open 100%5 mean valve open 5%|

A8

| Start/stop workingtemperature difference setting| 0.5-1.5|

1

A9| Control type of valve| 0: PID      1: Float   2:ON/OFF| 0
AA| Reset| When display 88, press       or      change the value to00, press to restore the factory settings, and the screen will be fully displayed for 2 seconds.|
AB| Valve Seal Type| 0:Soft Seal 1:Hard Seal| 0
AC| Descaling function| 0: Disable descaling function1: Enable descaling function| 1

RISK OF ELECTRICAL SHOCK
Please arrange professional technician to install the product according to drawings and instructions. Disconnect power supply before making any connection. Contact with components carryinghazardous

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYSEN User Manuals

Related Manuals