sunlite 122F LED Linear Strip Light Instruction Manual
- June 17, 2024
- sunlite
Table of Contents
sunlite 122F LED Linear Strip Light
Specifications:
- Ambient Operation Temperature: -20~50°C (-4 ~122°F)
- Supply Conductors: Min 90
- Locations: Suitable for damp locations
Product Usage Instructions
Ceiling Mount Installation:
- Insert J-Box cover into slots on the bottom of the fixture.
- Open the lens section, allowing the lens to hang off the fixture hinge.
- Drill mounting holes in the ceiling using the reference guide.
- Insert anchors into drilled holes and install the fixture using provided screws.
- Connect supply wires to fixture wires (Black to black, white to white, green to green). For 0-10V dimming, connect violet wire to positive dimming wire and grey wire to negative dimming wire.
- Select color temperature and wattage using switches on the side of the fixture.
Suspended Mount Installation (sold separately):
- Attach V-Hooks to existing keyholes on the fixture.
- Hang the V-Hooks on the chain.
- Wiring method is the same as ceiling mount. All wiring must go through a conduit.
Linking Bracket for Suspended Mount (sold separately):
- Insert the linking bracket on the fixture and secure with provided screws.
Corner Bracket for Corner Mount (sold separately):
- Drill mounting holes on the wall using the reference guide.
- Insert anchors into the mounting holes and attach the corner bracket on the wall by screwing screws into the anchors.
- Mount the fixture on the brackets using M4*10 screws.
FAQ:
What are the holes used for?
The holes are used for suspension installation (V-Hook), surface
installation (ceiling) and corner bracket installation, and surface
installation (ceiling with J-box).
INSTALLATION INSTRUCTIONS
LED LINEAR STRIP LIGHTS
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNINGS & CAUTIONS: Risk of fire or electric shock. Turn power off
before inspection, installation code by a person familiar with the
construction and operation of the product and the hazards involved. if you do
not have sufficient electrical wiring experience, please consult a qualified
electrician. To prevent wiring damage of abrasion, do not expose wiring to
edges of sheet metal or other sharp objects. Do not install this fixture where
there is risk of rain or moisture exposure. Install this kit only in the
luminaires that have construction features and dimensions shown in the
instructions. Ambient operation temperature -20℃~50 ℃(-4℉ ~122F). Min 90℃
supply conductors, Suitable for damp locations.
Remark: Ambient operation temperature -0℃~50 ℃(32℉ ~122F) for Emergency
Battery.
Installation
Wiring Diagram
What the holes used for?
- for Suspension installation(V-Hook).
- for Surface installation(ceiling) and cornner bracket installation.
- for Surface installation(ceiling with J-box).
Ceiling Mount
Suspended mount kit (sold separately) 85636-SU
- Attach V-Hooks to existing keyholes on the fixture.
- Hang the v-hook on the chain.
- Wiring method is the same as ceiling mount. All of the wiring must to through a conduit.
Linking Bracket for suspended mount(Sold separately)
Corner Bracket for corner mount(Sold seperately)
- Drill mounting holes on the wall using the reference guide below.
- Insert anchors into the mounting holes then attach the corner bracket on the wall by screwing. screws into anchors.
- Mount the fixture on the brackets by M4*10 screws.
With Emergency battery-4W (Sold separately)
With Emergency battery-6W OR 8W (Sold separately)
Motion Sensor (Sold separately)
Photocell (Sold separately)
Sunshine Lighting Company 744 Clinton Street Brooklyn, NY 11231, USA • T. 718.768.7000 • F. 718.768.0970 • www.sunlite.com