TECH KW-11m Input Sinum Card
The KW-11m input card is a device that takes a part in the exchange of information between sensors and devices connected to the card and the Sinum Central device. It is designed for mounting on a DIN rail. Communication with the Sinum central device is done by wire.
Specifications:
- Power supply
- Max. power consumption
- Operation temperature
- NTC Sensor thermal resistance
Product Usage Instructions
Control Lights Description
- Power supply
- Communication
- 1-4 – Two-state inputs status
Connectors Description:
- Registration button
- SBUS communication connector
- Two-state inputs connector (+24V)
- NTC sensor connector (1-4)
- 0-10V and 1-Wire inputs connector
How to Register the Device in the Sinum System
To identify the device in the Sinum Central, follow these steps:
- Activate the Identification Mode in Settings > Devices > SBUS Devices > + > Identification Mode tab.
- Hold the registration button on the device for 3-4 seconds.
- The device used will be highlighted on the screen.
The device should be connected to the Sinum central device using the SBUS connector 2, and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > + > Add device. Then briefly press the registration button 1 on the device. After a properly completed registration process, on the screen will apear a window to define function of each two-state inputs (button or two-state input). Additionally, at the end of registration, the user can name the device and assign it to a specific room.
How to identify the device in the Sinum system
To identify the device in the Sinum Central, activate the Identification
Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab
and hold the registration button on the device for 3-4 seconds. The device
used will be highlighted on the screen.
Technical data
Power supply | 24V DC ±10% |
---|---|
Max. power consumption | 1,5W |
Operation temperature | 5°C ÷ 50°C |
NTC Sensor thermal resistance | -30°C ÷ 50°C |
NOTE
TECH Controllers is not responsible for any damages resulting from improper
use of the system. The manufacturer reserves the right to improve devices,
update software and related documentation. The graphics are provided for
illustration purposes only and may differ slightly from the actual look. The
diagrams serve as examples. All changes are updated on an ongoing basis on the
manufacturer’s website.
Before using the device for the first time, read the following regulations
carefully. Not obeying these instructions may lead to personal injuries or
controller damage. The device should be installed by a qualified person. It is
not intended to be operated by children. It is a live electrical device. Make
sure the device is disconnected from the mains before performing any
activities involving the power supply (plugging cables, installing the device
etc.). The device is not water resistant.
The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.
EU Declaration of conformity
Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122) Hereby, we declare under our sole responsibility that the: KW-11m is compliant with Directive :
- 2014/35/UE
- 2014/30/UE
- 2009/125/WE
- 2017/2102/UE
For compliance assessment, harmonized standards were used:
- PN-EN IEC 60730-2-9:2019-06
- PN-EN 60730-1:2016-10
- EN IEC 63000:2018 RoHS
The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals
Frequently Asked Questions (FAQ)
How do I activate the Identification Mode?
To activate the Identification Mode, go to Settings > Devices > SBUS Devices > + > Identification Mode tab.
What is the purpose of the NTC sensor connector?
The NTC sensor connector is used to connect NTC sensors for temperature measurement.
Can the KW-11m input card be mounted on a DIN rail?
Yes, the KW-11m input card is designed for mounting on a DIN rail.
How do I contact customer service for technical support?
You can contact customer service for technical support by calling the provided telephone number or sending an email to the specified email address.
References
- controllers.com
- Intelligens fűtés-hűtés, fűtési-hűtési megoldások - TECH vezérlők gyártója | TECH vezérlők
- Sinum - TECH Controllers
- Intelligent heating, smart heating solutions - manufacturer of controllers | TECH Controllers
- Manuals - TECH Controllers
- TECH Controllers - Teplo ve Vašem domě
- TECH Controllers - Teplo vo Vašom dome
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>