Product Information

Specifications:

  • Product Name: Michael Phelps Chilly GOATTM Cold Tub by Master Spas
  • Power Cord Length: 12 feet
  • Ventilation Clearance: 6 feet on the front side, 2 feet on other sides

Product Usage Instructions

Planning for Access and Ventilation:
Place the Chilly GOAT on a flat, level surface, ideally a concrete pad that can support the weight when filled with water. Ensure there is sufficient clearance for access and ventilation as per the recommendations.

Waiting Period:
After placing the Chilly GOAT, wait for 24 hours before beginning the start-up process to allow for settling.

Accessing Equipment:
Remove the skirt cabinet panel and trim strip to access the equipment. Check unions and valves for security. Remove the filter before starting the filling process.

Setting Up Drain Line:
Connect the drain line located below the cabinet to prevent condensation. Route the drain line away from the unit to protect the cold tub.

Filling Your Cold Tub:
Attach a pre-filter to your garden hose, fill the cold tub to minimum water level, remove the pre-filter, and reinsert the filter into the housing.

Turning the Power On:
Turn on the power to your cold tub. If there is no water flow initially, restart the system until you feel flow coming from the jets.

Selecting Temperature:
Turn on the chiller power, press the power button for 3 seconds, wait 10 minutes to adjust the temperature, and use the up or down buttons accordingly.

FAQ

Q: How do I ensure proper ventilation for the Chilly GOAT cold tub?
A: Place the cold tub on a flat, level surface with at least 6 feet of clearance on the front side and 2 feet on other sides for adequate ventilation of the heat pump.

Q: What should I do if there is no water flow after turning on the cold tub?
A: If you hear the pump running but there is no water flow circulating, turn off the cold tub for 30 seconds and restart the system. Repeat until you feel flow coming from the jets.

Harness the power of cold water therapy with your Michael Phelps Chilly GOAT™ Cold Tub by Master Spas.
This step-by-step guide will ensure a smooth set-up process.

INSTRUCTION

PLANNING FOR ACCESS AND VENTILATION
Place your Chilly GOAT on a flat, level surface. A concrete pad is ideal. Just be sure that the foundation can support the weight of the cold tub when filled with water.
When choosing a location, it’s also important to consider the length of the power cord and space for access and ventilation. The Chilly GOAT cord is 12 feet long. In addition, Master Spas recommends having 6 feet of clearance on the front side for adequate ventilation of the heat pump and 2 feet of access on the other sides.
Move your Chilly GOAT into place and wait 24 hours before beginning the start- up process.

ACCESSING EQUIPMENT

Remove one skirt cabinet panel, and one trim strip to access the equipment.
The equipment end panel will be the short side with the top deck, and it is the primary access point for most equipment and startup processes. First,unscrew the trim strip. Then, remove the panel by lifting up the section until it stops and then pulling the bottom outward at an angle to unhook it from the channel.
With skirt panel removed from the equipment end, check that all unions are secure. Also, check that all slice valves are open and in the up position.
These connections and valves can shift or loosen during the shipping process.

Before starting the filling process be sure to remove the filter.

SET UP DRAIN LINE

It is normal for there to be condensation. To protect your cold tub, you need to connect the manufacturer installed drain line.

You’ll find the drain line on the long side of the Chilly GOAT below the cabinet. Attach the provided clear 3/8” ID hose to couple and route the drain line away from the unit, making sure not to allow water to return toward the Chilly GOAT.

FILLING YOUR COLD TUB

Attach a pre-filter to your garden hose. Place the hose in the cold tub and turn on the water. Once the water reaches the minimum water level, turn off the water and remove the pre-filter.
Dip your filter fully down into the water and reinsert it into the filter housing.

MASTER-SPAS-H2X-Michael-Phelps-Chilly-GOAT-Cold-Tub-6

TURN THE POWER ON TO THE COLD TUB

Turn the power on to your cold tub. Your circulation pump should start up immediately. If you hear the pump running, but there is no water flow circulating, turn your cold tub back off for 30 seconds and restart the system. Repeat this process until you feel flow coming from the jets. (Refer to owner’s manual for more detailed instructions).

SELECT TEMPERATURE
Turn on power to the chiller. Press the power button for 3 seconds. Then wait 10 minutes to adjust the temperature. This 10-minute window was designed to give you time to connect to the app in Step 7.
To change the temperature, press the up or down buttons accordingly.
You can press the “M” button to switch between the heating and cooling modes.

Reattach the filter housing.

CONNECTING TO THE SMART LIFE APP AND CONTROLLING YOUR COLD TUB

Your Chilly GOAT Cold Tub has a 2.4GHz Wi-Fi connectivity option. You can take advantage of this feature to control your heat pump and temperature setting.

To get started, while “NET” is flashing download the Smart Life app, which is available on the Google Play or Apple App stores. Sign up and register to create your account.
With your cold tub turned on, make sure that the circulation pump is moving water through the chiller.
Open the Smart Life app on your phone and log in to your account. Click the “+” in the upper right corner and select “Add Device.” Follow the directions on the app to add “Pool Heat Pump.”

NOTE: It might take several times to pair your cold tub depending on the strength of your Wi-Fi signal. Retry as needed or provide a stronger 2.4GHz Wi-Fi signal to the area where the cold tub is located.
Once connected to the Smart Life app, reattach the short end access panel and begin chilling.

SCAN QR CODE TO ACCESS HOW TO VIDEOS

6927 Lincoln Parkway, Fort Wayne, IN 46804
877-ChillyGOAT
Customer Service: [email protected] ChillyGOATtubs.com
Stay Connected, Keep in Touch

Master Spas® reserves the right to change product specifications or features without notice. Master Spas is a manufacturer of spas and related products, and we stand behind every product we produce pursuant to those representations which are stated in our written limited warranty. Your dealer is an independent businessperson or company and not an employee or agent of Master Spas, LLC. We cannot and do not accept any responsibility or liability for any other representations, statements or contracts made by any dealer beyond the provisions of our written limited warranty. Apple is a trademark of Apple Inc., registered in the U.S. and other countries. Google Play is a trademark of Google, LLC. Master Spas is a registered trademark of Master Spas, LLC.

Serial Number Transition T230116 and higher

POP23CGQSG-2 ©2023 Master Spas, LLC