FX Luminaire FX-269 FC LED Well Light Instruction Manual

June 17, 2024
FX Luminaire

FX Luminaire FX-269 FC LED Well Light

Product Information

Specifications

  • Product Type: In-Grade Light
  • Model Options: FC, RP, KT
  • Operating Voltage: 11-15 V
  • Maximum Power Capacity: 12.5 W

Product Usage Instructions

Changing Beam Angle Lens and Color Filter

  1. Remove and replace existing components for optional changes in beam angle lens and color filter.

Installation Steps

  1. Dig a hole and insert the construction sleeve.
  2. Use drainage material below the sleeve.
  3. Fill soil or concrete to the top of the sleeve cover if applicable.
  4. Ensure 11-15 V voltage at the fixture using a voltmeter.
  5. Connect wiring with a waterproof connector. (Optional) Install tamper-resistant screws.
  6. Replace the faceplate and screws.

FX-Luminaire FX-269-FC-LED-Well -Light-FIG- \(1\)

Circuiting Guidelines

LUXOR 15V 12 AWG (2.0 mm) < 160 W; 10 AWG (2.6 mm) < 180 W

FX-Luminaire FX-269-FC-LED-Well -Light-FIG- \(2\)

Transformers Information

Single Transformer:
Center the transformer on the wattage load. Minimize cable runs to reduce voltage drop.

Multiple Transformers:
Spread the load evenly across all transformers. Install transformers close to fixtures to avoid voltage drop.

Safety Instructions
Please read and keep all safety and use instructions. For questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

Low Voltage Cable Requirements
The low-voltage cable must comply with specified standards for safe usage.

Contact Information
If you have any questions or need assistance, please contact your local distributor or visit the support section at https://www.fxl.com/support.

Additional Information
Certifications: CE Certified In-Grade Lights: FC and RP Only, UL Listed: FC and RP Only, ETL Listed: KT Only © FX-269 IN 4/19

Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNINGTo reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug  when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth.  Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • Install all luminaires 10 feet (3.0 m) or more from a pool, spa, or fountain.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure  such as a house or deck.
  • Not be buried except for a maximum 6 feet (1.8 m) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6 feet (1.8 m) from a building structure, a luminaire, or fitting.

CE Certified In-Grade Lights: FC and RP Only
UL Listed: FC and RP Only ETL
Listed: KT Only

FAQ

Q: What is the recommended power capacity for 12 AWG and 10 AWG cables?
A: The recommended power capacity is less than 160 W for 12 AWG (2.0 mm) cables and less than 180 W for 10 AWG (2.6 mm) cables.

Q: How can I ensure proper voltage at the fixture?
A: Use a voltmeter to verify that the voltage at the fixture falls within the range of 11-15 V.

Q: Are tamper-resistant screws necessary for installation?
A: Tamper-resistant screws are optional but recommended for added security.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FX Luminaire User Manuals

Related Manuals