FX Luminaire CA-51 Accent and Wall Wash Installation Guide

June 12, 2024
FX Luminaire

FX Luminaire logo

FX Luminaire CA-51 Accent and Wall Wash

Product Information

The product is a landscape and architectural lighting fixture available in designer and standard versions. It is suitable for accent and wall wash applications. The specific models are XA, XW, and CA-51.

Product Usage Instructions

  1. Pound the stake into the ground.
  2. Thread the fixture into the stake. Coil any extra wire for future servicing.
  3. Use a voltmeter to ensure that the voltage at the fixture is between 11 to 15 V.
  4. Connect the wiring using a waterproof connector.
  5. Aim the fixture as desired.
  6. To control glare, rotate the fixture. Loosen the set screw, adjust the fixture, and then retighten the set screw.

INSTALLATION

  1. Pound stake into ground.
  2. Thread fixture into stake. Coil extra wire for future servicing.
  3. Use voltmeter to ensure 11 to 15 V at fixture.
  4. Connect wiring with waterproof connector.
  5. Aim fixture as desired.
  6. Rotate fixture for glare control. Loosen set screw and adjust fixture, then retighten set screw.FX Luminaire CA-51 Accent and Wall Wash-fig-1

CIRCUITING GUIDELINES

FX Luminaire CA-51 Accent and Wall Wash-
fig-2

Transformer

When using a single transformer, center it on the wattage load and minimize cable runs to reduce voltage drop. When using multiple transformers spread the load evenly and install them as close to the fixtures as possible to avoid voltage drop. For voltage drop calculation, visit fxl.com/voltage-drop- calculator.

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.

Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.
For voltage drop calculation, visit fxl.com/voltage-drop- calculator.

Safety and Support

Please read and keep all safety and use instructions. If you have any questions, contact your local distributor or visit the online support section at fxl.com/support. These products contain a light source of energy efficiency class G.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the fixture fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A fixture shall not use tungsten halogen lamps unless the fixture is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW-VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the fixture or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a fixture, or fitting.

CE Certified Products: XA, XW Only Non-CE
Certified Product: CA-51

Landscape & Architectural Lighting
Learn more. Visit fxl.com

fxl.com/support
These products contain a light source of energy efficiency class G.
CE Certified Products: XA, XW Only
Non-CE Certified Product: CA-51