FX Luminaire 140356 QB LED Up Light Instruction Manual
- June 12, 2024
- FX Luminaire
Table of Contents
FX Luminaire 140356 QB LED Up Light
Product Information
The product is a Designer/Standard Up Light that operates at 11-15 V. It has a wattage of 12.5 and is compatible with the Luxor system. The product comes with circuiting guidelines and is available in various voltage options, including 15 V.
INSTALLATION
- Change beam angle lens and color filter by removing and replacing existing components (optional).
- Pound stake into ground.
- Thread fixture into stake. Coil extra wire for future servicing.
- Use voltmeter to ensure 11 to 15 V at fixture.
- Connect wiring with waterproof connector.
- Aim fixture as desired.
GUIDELINES
CIRCUITING GUIDELINES
TRANSFORMERS
- Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
- Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.
PRECAUTION
UP LIGHT: Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.
WARNING: To reduce the risk of FIRE OR INJURY TO PERSON:
- Turn off/unplug and allow to cool before replacing lamp.
- Lamp gets HOT quickly. Contact only switch/plug when turning on.
- Do not touch hot lens, guard, or enclosure.
- Keep lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
- Do not operate the luminaire fitting with a missing or damaged shield.
WARNING: Risk of Electric Shock
- May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
- A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
- Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.
LOW VOLTAGE CABLE SHALL
-
Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure *
such as a house or deck. -
Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low voltage cable.
-
Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.
These products contain a light source of energy efficiency class G.
CE Certified Up Lights: CC, FB, FR, LC, NP, NR, PB, QB, QZ, VS, LO, LR, MU and
RS Only
Non-CE Certified Up Lights: C-UL, C-WW, MP, RL, SI, WS
Learn more. Visit fxl.com