FX Luminaire VO-ZD-1LED-GW-180-SS VO Wall Light Instruction Manual

June 12, 2024
FX Luminaire

FX-Luminaire-LOGO

FX Luminaire VO-ZD-1LED-GW-180-SS VO Wall Light

Product Information

The Designer/Standard Wall Light is a low-voltage outdoor lighting fixture designed for landscape and architectural lighting. It is available in various models, including PO, MO, VO, and CG.The dimensions of the wall light vary depending on the model: PO has a diameter of 1.5 inches (38 mm) and uses SCH 40 conduit, MOhas a diameter of 2.0 inches (51 mm) and uses SCH 40 conduit, VO has a diameter of 1.7 inches (45 mm) and requires a custom conduit, and CG has no specified dimensions. The wall light operates at a voltage range of 11-15 V and has a power consumption of 12.5 watts. It is suitable for both installation on walls and concrete ground-mount options.

Product Usage Instructions

English Installation

  1. Use the provided conduit and trim its length if necessary.
  2. During construction, install the conduit sleeve into the wall.
  3. Run the fixture wiring through the sleeve.
  4. *For VO fixtures only: Use the provided coupling.
  5. Ensure that there is a voltage of 11 to 15 V at the fixture using a voltmeter.
  6. Connect the wiring with waterproof connectors.
  7. Press the faceplate into the sleeve.
  8. Level and orient the fixture as desired.

Circuiting Guidelines

LUXOR 15 V:
When using a single transformer, center it on the wattage load and minimize cable runs to reduce voltage drop. For multiple transformers, evenly spread the load across all transformers and install them as close to the fixtures as possible to avoid voltage drop.

Transformers

CE Certified: PO and MO Only
UL Listed: PO, MO, and CG Only
ETL Listed: VO Only
For more information, visit fxl.com/support.

INSTALLATION

FX-Luminaire-VO-ZD-1LED-GW-180-SS VO-Wall-Light-FIG-1

  1. Use provided conduit, and trim length if necessary.
  2. Install conduit sleeve into wall during construction. Run fixture wiring through sleeve. *Coupling for VO fixture only.
  3. Use voltmeter to ensure 11 to 15 V at fixture.
  4. Connect wiring with waterproof connector.
  5. Press faceplate into sleeve. Level and orient fixture as desired.
  • For concrete ground-mount option, use construction housing.

CIRCUITING GUIDELINES

FX-Luminaire-VO-ZD-1LED-GW-180-SS VO-Wall-Light-FIG-2

TRANSFORMERS

  • Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
  • Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

Please read and keep all safety and use instructions.
If you have questions, contact your local distributor or visit the online support section at fxl.com/support.

WARNINGTo reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW-VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.

fxl.com/support
These products contain a light source of energy efficiency class G.

  • MO, PO, and VO
  • CG – None

CE Certified: PO and MO Only
UL Listed: PO, MO and CG Only
ETL Listed: VO Only
LANDSCAPE & ARCHITECTURAL LIGHTING | Learn more. Visit fxl.com