FX Luminaire SRP RGBW Strip Light Instruction Manual

June 9, 2024
FX Luminaire

SPECIALTY LIGHT | SRP
Instruction Manual

INCLUDED COMPONENTS

COMPONENTES INCLUIDOS

TOOLS & MATERIALS REQUIRED (SOLD SEPARATELY)

FX Luminaire SRP RGBW Strip Light - SEPARATELY

HERRAMIENTAS Y MATERIALES

CIRCUITING GUIDELINES

|
---|---
fxl.help/circuiting| fxl.help/SRP

INSTALLATION

1. Measure and cut the length requiredfor installation.| 2. Insert the U-Spacer into the end of the strip light.
---|---
|
3. Insert a Jumper Wire into the strip light. Ensure jumper pins are installed on top of the copper pads. Use the Pick Tool to expose the pads prior to installing the jumper.| 4. Install the clear plastic Clamp onto the jumper connection. Press down
firmly. Gently pull the connection to confirm it is secure.
|
5. Insert the End Connector on the opposite end. Install the Clamp. Press
down firmly. Pull the connection are ato confirm it is secure.| 6. Starting at one end, insert the strip slight into the aluminum SRP-CHN
Channel Mount. (If using the SRP-MNT Hardscape Mount, skip this step and move directly to Step 7.)
|
7. Press the strip light into the installed SRP-MNT Hardscape Mount. The
ideal placement is one mount every 20″ (508 mm) or less.|

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.

  • Lamp gets HOT quickly. Contact only switch/plug when turning on.

  • Do not touch hot lens, guard, or enclosure.

  • Keep lamp away from materials that may burn.

  • Do not touch the lamp at any time. Use a soft cloth.
    Oil from skin may damage lamp.

  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.

This product contains a light source of energy efficiency class G. LANDSCAPE & ARCHITECTURAL LIGHTING
Learn more. Visit fxl.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FX Luminaire User Manuals

Related Manuals