GENERAL FH101S Underfloor Heating Thermostat User Manual

June 17, 2024
GENERAL

GENERAL FH101S Underfloor Heating Thermostat

GENERAL-FH101S-Underfloor-Heating-Thermostat-fig-1

Product Information

General Specifications

  • FH101S is a floor heating room thermostat.

  • Provides comfortable and affordable heating by setting the
    desired room temperature.

  • Sensitive Temperature Measurement

  • Wired Connection

  • ON / OFF Control

Technical Data

  • Dimensions (H / L / W ): 150 cm
  • Operating Current
  • Relay NO Switching Current
  • Temperature Measurement Accuracy
  • Operating Sensitivity
  • Operating Temperature Range
  • Operating Temperature Storage Temperature

Room Thermostat Features

  • Indicator LED
  • Set Button
  • Room Thermostat Indicator LED Descriptions:
    • LED light is on – Heating unit is working
    • LED light is off – Heating unit is not working

Placement Recommendations

Place the Room Thermostat in a frequently used room, such as the hall or living room, avoiding areas with excessive air circulation, direct sunlight, or near heating units. Mount the thermostat at a height of 150 cm from the floor.

Warranty Information

  • Product Type : Floor Heating Room Thermostat
  • Brand : GENERAL Life
  • Model: FH101S
  • Warranty Period : 2 Years
  • Max. Time to Repair : 20 Days

Declaration of Conformity

The product FH101S by GENERAL Life complies with Electromagnetic Compatibility Regulation and Low Voltage Directive. For detailed information, refer to the user manual.

Warranty Certificate

  • Product Type : Floor Heating Room Thermostat
  • Brand : GENERAL Life
  • Model: FH101S

FAQ

  • Where should I place the Room Thermostat?
    Place the Room Thermostat in a room with frequent use, such as the hall or living room, avoiding areas with high air circulation, direct sunlight, or near heating units.

  • What should I do if the indicator LED is not working?
    If the LED indicator is not functioning, check the power connection and consult the user manual for troubleshooting steps.

  • Can the Room Thermostat be installed with other floor sensors?
    Only install a floor sensor compatible with GENERAL Life products to avoid warranty issues.

GENERAL SPECIFICATIONS

FH101S is a floor heating room thermostat. User provides more comfortable and affordable heating by setting needed room temperature.

  • Sensitive Temperature Measurement
  • Wired Connection
  • ON / OFF Control

FH101S AND EQUIPMENTS

  • FH101S Room Thermostat
  • Dowels and Screws

TECHNICAL DATA

  • Dimensions ( H / L / W ) 85.7mm / 85.7mm / 33.5mm
  • Operating Current 230V AC
  • Relay NO Switching Current
    • 7A (240VAC – Resistive load)
    • 10A (120VAC – Resistive load)
  • Temperature Measurement Accuracy 0.1 C
  • Operating Sensitivity 0.5 C
  • Operating Temperature Range (5 C) – (30 C)
  • Operating Temperature (-10 C) – (+50 C)
  • Storage Temperature -20 C) – (+60 C)

ROOM THERMOSTAT

Room Thermostat Indicator LED Descriptions

  • LED light is on Heating unit is working
  • LED light is off Heating unit is not working

ROOM THERMOSTATPLACEMENT

Place your Room Thermostat in a room you use frequently in your living space. For example; like the hall or living room of your home. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. Also, do not place it close to heating units (heater core, fireplace, etc.) and in direct sunlight. We recommend that the room thermostat is placed at a height of 150 cm from the floor.

GENERAL-FH101S-Underfloor-Heating-Thermostat-fig-4

ROOM THERMOSTAT WORKING PRINCIPLE

  • As soon as you energize your Room Thermostat, it will start working.
  • Your Room Thermostat measures the temperature of the environment it is in every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you set, your Room Thermostat turns off the heating unit, and if it falls below 0.5 degrees, it turns on the heating unit.
  • If the floor sensor measures temperature above 28°C, it turns off the heating unit. The floor sensor operating sensitivity is ±1°C.*
  • Thus, it is ensured that the ambient temperature remains within a certain range.
    *External floor sensor is only active when it is connected.
    Note: If a floor sensor is installed with Room Thermostat, only GENERAL Life floor sensor should be installed. Otherwise, the product will be out of warranty

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL-FH101S-Underfloor-Heating-Thermostat-fig-5

WIRING DIAGRAM FOR ACTUATOR

WIRING DIAGRAM FOR WIRING CENTER

WARNING!
Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications.

DECLARATION OF CONFORMITY

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and warranted against manufacturing defects for 2 years.
  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
  3. The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should send by contracte transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
  4. The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belongs to the customer.
  5. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
  7. In the event that the faults of the devices and apparatus whosewarranty period continues are determined as caused by the customer, all expenses would be belong to the customer.
  8. Customers should be aware of damages (if there is any) of product and warn manufacturer since the day warranty duration starts.If customer do not warn manufacturer with knowledge of damage, customer lose the rights of article 6.
  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty
  10. Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.
  11. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
  12. Battery leakage and errors due to rust, oxidation and liquid contact by working in acidic / humid environments are not covered by the warranty.
  13. When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take a transportation insurance.
  15. Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.
  16. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake etc.
  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.
  18. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during repairment period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumer can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However,in case of a conflict , responsibility of prove is belong to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer orimporter; has to allocate another product with similar features to theuse of the consumer until the repair of the product is completed.
  19. Although the consumer uses his/her repair rights, -If the product breaks down for 4 times in a year or 6 times in warranty duration and these problems effects main purpose of the product. (starting from delivery time during warranty.) – Exceeding the maximum time required for repair, – In the event that the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested.
  20. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
  21. The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices andapparatus will be made for a fee.

WARRANTY CERTIFICATE

  • Manufacturer
    • Title: ISIPARK İÇ DIŞ TİC. A.Ş.
    • Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
    • Gaziemir İzmir-TÜRKİYE
    • Tel: +90 (232) 457 99 50
    • Fax: +90 (232) 457 91 22
    • E-mail: generallife@generallife.com.tr
    • Authorized Signature:
    • Company Stamp:
  • Product
    • Type: Floor Heating Room Thermostat
    • Brand: GENERAL Life
    • Model: FH101S
    • Warranty Period: 2 Years
    • Max. Time to Repair: 20 Days
    • Bandrol and Serial Number