Ventilation systems range
2023 / 2024
2023 Ventilation ERV Heat Exchanger
Panasonic ventilation solutions
Panasonic ventilation solutions for maximum savings and easy
integration.’
Air handling unit kit
AHU connection kits connect outdoor units to air handling systems. Combines
air conditioning and fresh air in just one solution.
Application: Hotels, offices, server rooms or all large buildings where air
quality control, such as humidity control and fresh air, is needed. AHU connection kit for PACi, ECOi and ECO G.
PACi NX and PACi: 3,6 to 28,0 kW.
ECOi and ECO G: 16, 28 and 56 kW.
- Durable metal casing (IP66) allows external installation
- 0-10 V demand control
- CONEX Bluetooth® control built-in (CZ-RTC6BL)
- Panasonic H&C Control App via Bluetooth®
- Easy integration to BMS
The Panasonic AHU connection kits offer a wealth of connectivity
possibilities, integrating easily into many systems.
Besides the advantages in terms of indoor air quality, air conditioning offers
also an energy saving potential. For example, uncontrolled ventilation through
open windows leads to large amounts of heat being lost to the outside during
the heating season or gained from the outside during the cooling season.
Whereas, combining heat recovery with air conditioning can allow for a high
level of comfort whilst reducing the overall operating costs of running air
conditioning alone. The larger area of the comfort range, the better the
energy saving opportunities.
Panasonic AHU connection kit connected to outdoor unit
Demand control on the outdoor unit managed by external 0-10 V signal.
- AHU connection kit contains: IP66 box with PCBs and terminal connections mounted inside, expansion valve and sensors
- Heat exchanger, fan and fan motor to be mounted in the AHU itself are field supplied
Main components of mechanical ventilation systems
- Air handling unit (AHU)
- Air ducts
- Air distribution elements
Optional parts: Following functions are available by using different control accessories:
Timer remote controller.
CZ-RTC5B.
DC 12 V outlet. Option terminal.
PAW-OCT. Mini seri-para I/O unit.
CZ-CAPBC2
Advanced version only.
PCB to connect to T10 connector.
CZ-T10 terminal / PAW-T10 PCB
AHU connection kit 3,6 to 28,0 kW for PACi NX and PACi
Compatible with R32 or R410A outdoor units.
AHU connection kit| |
---|---|---
Reference| IP66| **0-10 V demand control***
PAW-280PAH3M-1| Yes| Yes
Control options
Control option 1.
- The system’s control is simple: control of actual suction temperature vs. set point
- Control works in the same way as that of any indoor unit
- Fan signal issued by the PCB (OFF while defrosting, for instance)
Control option 2.
- System control by a 0-10 V control working from an external BMS that manages the set point for temperature or capacity. Enhances efficiency by adjusting capacity and enhances comfort as well
- All signals as standard
0-10 V control
With the 0-10 V demand control the capacity of the outdoor unit can be
controlled by 20 steps.
Input voltage* (V)| 0| 1,0| 1,5| 2,0| 2,5| 3,0| 3,5| 4,0| 4,5| 5,0| 5,5| 6,0|
6,5| 7,0| 7,5| 8,0| 8,5| 9,0| 9,5
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Demand (% of nominal current)| No cut 1)| 40| 45| 50| 55| 60| 65| 70| 75| 80|
85| 90| 95| 100| 105| 110| 115| 120| No limit / Full capacity 2)
Indoor unit start / stop| Stop 1)| Start
- No cut / stop: AHU system / indoor unit is completely switched OFF.
- No limit: No restrictions applied by BMS to AHU system / indoor unit performance (equivalent to “full-load operation“ of AHU system / indoor unit).
AHU connection kit 3,6 to 28,0 kW for PACi NX and PACi
PAW-280PAH3M-1| | | 3,6 kW| 5,0 kW| 6,0 kW| 7,5 kW|
10,0 kW| 12,5 kW| 14,0 kW| 20,0 kW| 25,0 kW
Cooling capacity| | kW| 3,6| 5,0| 6,0| 7,1| 10,0| 12,5| 14,0| 19,5| 23,2
Heating capacity| | kW| 4,0| 5,6| 7,0| 8,0| 11,2| 14,0| 16,0| 22,4| 28,0
Air flow| Min / Max| m³/h| 540 / 870| 630 / 990| 780 / 1320| 780 / 1320| 900 /
2160| 1140 / 2280| 1200 / 2400| 2160 / 4320| 2280 / 5040
Dimension| H x W x D| mm| 500 x 400 x 150| 500 x 400 x 150| 500 x 400 x 150|
500 x 400 x 150| 500 x 400 x 150| 500 x 400 x 150| 500 x 400 x 150| 500 x 400
x 150| 500 x 400 x 150
Net weight| | kg| 11,5| 11,5| 11,5| 11,5| 11,5| 11,5| 11,5| 11,5| 11,5
Pipe length range| Standard| m| 3 ~ 15| 3 ~ 20| 3 ~ 40| 3 ~ 40| 5 ~ 50| 5 ~
50| 5 ~ 50| —| —
Elite| m| 3 ~ 40| 3 ~ 40| 3 ~ 40| 5 ~ 50| 5 ~ 85| 5 ~ 85| 5 ~ 85| 5 ~ 90| 5 ~
60
Elevation difference (in / out)| Max| m| 30| 30| 30| 30| 30| 30| 30| 30| 30
Piping diameter| Liquid| Inch (mm)| 1/4 (6,35)| 1/4 (6,35)| 3/8 (9,52)| 3/8
(9,52)| 3/8 (9,52)| 3/8 (9,52)| 3/8 (9,52)| 3/8 (9,52)| 1/2 (12,70)
Gas| Inch (mm)| 1/2 (12,70)| 1/2 (12,70)| 5/8 (15,88)| 5/8 (15,88)| 5/8
(15,88)| 5/8 (15,88)| 5/8 (15,88)| 1 (25,40)| 1 (25,40)
Intake temperature of AHU connection kit| Cool Min ~ Max| °C DB| 18 ~ 32| 18 ~
32| 18 ~ 32| 18 ~ 32| 18 ~ 32| 18 ~ 32| 18 ~ 32| 18 ~ 32| 18 ~ 32
Cool Min ~ Max| °C WB| 14 ~ 25| 14 ~ 25| 14 ~ 25| 14 ~ 25| 14 ~ 25| 14 ~ 25|
14 ~ 25| —| —
Heat Min ~ Max| °C| 16 ~ 30| 16 ~ 30| 16 ~ 30| 16 ~ 30| 16 ~ 30| 16 ~ 30| 16 ~
30| 16 ~ 30| 16 ~ 30
Ambient temperature of outdoor unit (Standard)| Cool Min ~ Max| °C| -10 ~ +43|
-10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43|
-10 ~ +43
Heat Min ~ Max| °C| -15 ~ +24| -15 ~ +24| -15 ~ +24| -15 ~ +24| -15 ~ +24| -15
~ +24| -15 ~ +24| -15 ~ +24| -15 ~ +24
Ambient temperature of outdoor unit (Elite)| Cool Min ~ Max| °C| -15 ~ +46|
-15 ~ +46| -15 ~ +46| -15 ~ +46| -20 ~ +48| -20 ~ +48| -20 ~ +48| -20 ~ +48|
-20 ~ +48
Heat Min ~ Max| °C| -20 ~ +24| -20 ~ +24| -20 ~ +24| -20 ~ +24| -20 ~ +24| -20
~ +24| -20 ~ +24| -20 ~ +24| -20 ~ +24
System and regulations. System overview.
1 | AHU equipment (field supplied)
2 | AHU system controller (field supplied)
3 | AHU connection kit controller box (with control PCB)
4 | Thermistor for gas pipe (E2)| 5 | Thermistor for liquid pipe (E1)
6 | Thermistor for suction air
7 | Inter-unit wiring
8 | Outdoor unit
---|---
AHU connection kit.
PCB, power trans, terminal block
Thermistor x2 (refrigerant: E1, E2). Thermistor (air: TA; 1 sensor).
Wired remote controller.
CZ-RTC6BL
New AHU connection kit 14,0 to 189,0 kW for ECOi and ECO G
AHU connection kit| |
---|---|---
Reference| IP66| **0-10 V demand control***
PAW-160MAH3M / PAW-280MAH3M / PAW-560MAH3M| Yes| Yes
With ECOi outdoor units
ECOi outdoor units shall be used for AHU connection kit. 3 models for VRF
system: 5 HP (PAW-160MAH3M), 10 HP (PAW-280MAH3M) and 20 HP (PAW-560MAH3M).
With ECO G outdoor units
- One AHU connection kit may be used for one ECO G unit. Multiple AHU connection kits cannot be used· Mixed with standard indoor units is not allowed
- Power specifications are single phase 220 V to 240 V
NEW AHU connection kit 14,0 to 189,0 kW for ECOi and ECO G
| | | 5 HP| 10 HP| 20 HP| 30 HP| 40 HP| 50 HP|
60 HP
Reference| | PAW-| 160MAH3M| 280MAH3M| 560MAH3M|
280MAH3M| 560MAH3M| 560MAH3M| 560MAH3M
| | | | | | 560MAH3M| 560MAH3M| 560MAH3M| 560MAH3M
| | | | | | | | 280MAH3M| 560MAH3M
Cooling capacity| | kW| 14,0| 28,0| 56,0| 84,0| 112,0| 140,0| 168,0
Heating capacity| | kW| 16,0| 31,5| 63,0| 95,0| 127,0| 155,0| 189,0
Air flow| Cool Min / Max| m³/h| 2598 / 1140| 4998 / 3498| 10002 / 7002| 15000
/ 10500| 19998 / 13998| 24996 / 17496| 30000 / 21000
Bypass factor recommended| | | 0,9| 0,9| 0,9| 0,9| 0,9| 0,9| 0,9
Dimension| H x W x D| mm| 278 x 278 x 180| 278 x 278 x 180| 278 x 278 x 180|
278 x 278 x 180| 278 x 278 x 180| 278 x 278 x 180| 278 x 278 x 180
Net weight| | kg| 3,2| 6,3| 6,3| 6,3| 6,3| 6,3| 6,3
Pipe length range| | m| 10 ~ 100| 10 ~ 100| 10 ~ 100| 10 ~ 100| 10 ~ 100| 10 ~
100| 10 ~ 100
Elevation difference (in / out)| Max| m| 10| 10| 10| 10| 10| 10| 10
Piping diameter| Liquid| Inch (mm)| 3/8 (9,52)| 3/8 (9,52)| 5/8 (15,88)| 3/4
(19,05)| 3/4 (19,05)| 3/4 (19,05)| 3/4 (19,05)
Gas| Inch (mm)| 5/8 (15,88)| 7/8 (22,22)| 1 1/8 (28,58)| 1 1/4 (31,75)| 1 1/2
(38,15)| 1 1/2 (38,15)| 1 1/2 (38,15)
Intake temperature of AHU connection kit| Cool Min ~ Max| °C DB| +18 ~ +32|
+18 ~ +32| +18 ~ +32| +18 ~ +32| +18 ~ +32| +18 ~ +32| +18 ~ +32
Cool Min ~ Max| °C WB| +13 ~ +23| +13 ~ +23| +13 ~ +23| +13 ~ +23| +13 ~ +23|
+13 ~ +23| +13 ~ +23
Heat Min ~ Max| °C| +16 ~ +30| +16 ~ +30| +16 ~ +30| +16 ~ +30| +16 ~ +30| +16
~ +30| +16 ~ +30
Ambient temperature of outdoor unit| Cool Min ~ Max| °C| -10 ~ +43| -10 ~ +43|
-10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43| -10 ~ +43
Heat Min ~ Max| °C| -20 ~ +15| -20 ~ +15| -20 ~ +15| -20 ~ +15| -20 ~ +15| -20
~ +15| -20 ~ +15
AHU connection kit / system combination
Capacity| | | ECOi Series| | AHU kit| | Capacity| | ECO
G Series| AHU kit
5 HP| 16 kW| | All ECOi| | 160MAH3| —| —| 5 HP| 16 kW|
All ECO G| 160MAH3
10 HP| 28 kW| U-10ME2E8| —| —| 280MAH3| —| —| 10 HP| 28
kW| All ECO G| 280MAH3
20 HP| 56 kW| U-20ME2E8| —| —| 560MAH3| —| —| 20 HP| 56
kW| U-20GE3E5| 560MAH3
30 HP| 84 kW| U-16ME2E8| U-14ME2E8| —| 560MAH3| 280MAH3| —|
40 HP| 112 kW| U-20ME2E8| U-20ME2E8| —| 560MAH3| 560MAH3| —
50 HP| 140 kW| U-18ME2E8| U-16ME2E8| U-16ME2E8| 560MAH3| 560MAH3|
280MAH3
60 HP| 168 kW| U-20ME2E8| U-20ME2E8| U-20ME2E8| 560MAH3| 560MAH3|
560MAH3
Technical focus
-
Maximum capacity / system: 60 HP (189 kW)
-
Maximum piping length: 100 m (120 m equivalent)
-
Elevation difference (indoor unit / indoor unit): 4 m
-
In / out capacity ratio: 50~100%
-
Maximum number of AHU connection kits: 3 units*
-
Outdoor temperature range in heating: -20 ~ +15 °C
-
Available temperature range for the suction air at AHU connection kit: cool: +18 ~ +32 °C / heat: +16 ~ +30 °C
-
The systems is controlled by the suction air (or room return air) temperature (same as standard indoor unit)
-
The discharge air temperature is also controlled to prevent too-low air discharge in cooling or too-high air discharge in heating (in case of VRF)
-
Demand control (forcible thermostat-OFF control by operating current)
-
Defrost operation signal, Thermo-ON / OFF states output
-
Drain pump control (drain-pump and the float switch to be supplied in local)
-
External target temperature setting via indoor / outdoor signal interface is available with CZ-CAPBC2 (Ex. 0-10 V)
-
Demand control 40% to 120% (5% steps) by 0-10 V input signal
-
Connectable with S-Link system. Special care for electrical noise may be necessary depending on the on-site system
-
Fan control signal from the PCB can be used to control the air flow (high / mid / low and LL for Th-OFF). Need to change the fan control circuit wiring at field
-
To be simultaneous operation controlled by one remote controller sensor.
System and regulations. System overview.
1 | AHU Unit equipment (field supplied)
2 | AHU Unit system controller field supplied)
3 | AHU connection kit controller box (with control PCB)
4 | Thermistor for discharge air
5 | Electronic expansion valve| 6 | Thermistor for gas pipe (E3)
7 | Thermistor for liquid pipe (E1)
8 | Thermistor for suction air
9 | Inter-unit wiring
10 | Outdoor unit
---|---
New advanced ERV ZY Series.
- Extended 9 model line-up including 2 000 m³/h model
- DC motors
- ESP up to 150 Pa
- F7 grade filter built-in as a standard
- New intuitive remote controller
- BMS integration with RS485
New advanced energy recovery ventilation ZY Series
Recovers up to 83% of the heat in the outgoing air
ZY Series achieves more than 80% of heat exchange efficiency in all the line- up
- The high recovery rate optimizes operation cost and can be considered as a sustainable solution. 1) Heating operation, H1 speed setting.
Easy adjust for air volume
balance
DC motors are equipped with independent control settings for air supply and
exhaust. Air volume balance can be easily adjusted with 4 speeds settings for
each Hi / Low operation.
Highly efficient filter for better air supply
An effective EN F7 grade filter is built-in as a standard.
Expected cleaning maintenance cycle is once per month, with an average of 4-6
months for replacement in high demand environments. Backdraft shutters
equipped as standard
A backdraft shutter prevents air flowing in the wrong direction when the ERV
system is not in operation.
The shutter at OA (outside air intake) side is inter-locked with ON / OFF
switch.
The shutter at EA (exhaust air outlet) side opens with the pressure generated
by air stream then closes automatically.
New intuitive remote controller with RS485 connection
- Simple and clean screen with white back light panel
- RS485 terminal equipped to integrate with Building Management Systems
- Metal switch box is included in the package
NEW advanced energy recovery ventilation
Rated flow rate| | | 150 m³/h| 250 m³/h| 350 m³/h| 500
m³/h| 650 m³/h| 800 m³/h| 1000 m³/h| 1500 m³/h| 2000
m³/h
---|---|---|---|---|---|---|---|---|---|---|---
Indoor unit| | | FV-15ZY1G| FV-25ZY1G| FV-35ZY1G| FV-
50ZY1G| FV-65ZY1G| FV-80ZY1G| FV-1KZY1G| FV-1HZY1G|
FV-2KZY1G
| Voltage| V| 220 – 240| 220 – 240| 220 – 240| 220 – 240| 220 – 240| 220 –
240| 220 – 240| 220 – 240| 220 – 240
Power supply| Phase| | Single phase| Single phase| Single phase| Single phase|
Single phase| Single phase| Single phase| Single phase| Single phase
| Frequency| Hz| 50| 50| 50| 50| 50| 50| 50| 50| 50
Motor type| | | DC| DC| DC| DC| DC| DC| DC| DC| DC
ERV| | | | | | | | | | |
Air flow| Max| m³/h| 150| 250| 350| 500| 650| 800| 1000| 1500| 2000
External static pressure| Max| Pa| 100| 120| 140| 130| 150| 150| 150| 130| 130
Sound power 2)| Max| dB(A)| 37| 38| 39| 43| 45| 45| 46| 49| 51
Input power| Max| W| 76 ~ 84| 106 ~ 117| 141 ~ 155,5| 180 ~ 198| 420 ~ 462|
470 ~ 517| 550 ~ 605| 940 ~ 1034| 1100 ~ 1210
Heat exchange efficiency 3)
Cooling| Max| %| 68,0| 69,0| 71,0| 65,0| 64,0| 63,0| 65,0| 63,0| 65,0
Heating| Max| %| 83,0| 82,0| 83,0| 81,0| 82,0| 83,0| 82,0| 83,0| 82,0
Enthalpy exchange efficiency
Cooling| Max| %| 66,0| 66,0| 67,0| 62,5| 62,5| 63,5| 63,0| 63,5| 63,0
Heating| Max| %| 76,0| 74,0| 75,0| 73,0| 72,0| 73,0| 74,0| 73,0| 74,0
Adapter diameter| | mm| 100| 150| 150| 200| 200| 250| 250| 250| 250
Dimension 3)| H x W x D| mm| 289 x 610
x 860| 289 x 735
x 860| 331 x 874
x 968| 331 x 1016
x 968| 404 x 954
x 1008| 404 x 1004
x 1224| 404 x 1231
x 1224| 808 x 1004
x 1224| 808 x 1231
x 1224
Net weight| | kg| 23| 27| 37| 40| 48| 56| 64| 116| 139
- Different dimensions depending on models.
- Measurement of noise 1,5 m below the center of the main unit (anechoic chamber).
- Heat exchange efficiency measurement standard JIS B 8628 (2003).
JIS B 8628 (2017) is used in the measurement environment.
Available in Autumn 2023.
Remote controller image is tentative.
Accessories
FV-FP15ZY1G | Replacement high efficiency filter for FV-15ZY1G |
---|---|
FV-FP25ZY1G | Replacement high efficiency filter for FV-25ZY1G |
FV-FP35ZY1G | Replacement high efficiency filter for FV-35ZY1G |
FV-FP50ZY1G | Replacement high efficiency filter for FV-50ZY1G |
FV-FP65ZY1G | Replacement high efficiency filter for FV-65ZY1G |
V-FP80ZY1G | Replacement high efficiency filter for FV-80ZY1G and FV-1HZY1G* |
FV-FP1KZY1G | Replacement high efficiency filter for FV-1KZY1G and FV-2KZY1G* |
* 2 sets of filters required for those models.
Heat recovery with DX coil for VRF
Panasonic heat recovery solution for greater energy efficiency.
Performing well in extreme weather conditions, it can achieve up to 77%
efficiency (63% in enthalpy efficiency).
The counter-flow heat exchanger reduces the air conditioning load, enabling
customers – typically owners of hotels, restaurants and other large commercial
buildings – to reduce their energy consumption and save on the cost of
maintaining comfortable room temperatures.
Energy efficiency
These heat recovery devices are an example of Panasonic’s continued commitment
to developing unbeatable, energy-efficient air conditioning technologies for
commercial applications.
The unit features a DX coil, and is designed to recover up to 77% of the heat
from outgoing air, and an air purifying system which helps to improve air
quality.
In even the most demanding commercial applications, business owners will
benefit from the unit’s ability to by-pass the heat exchange process when the
outside air temperature is cool enough for fresh air to be drawn directly
inside (free cooling). This alleviates the load on the air conditioning
equipment and consequently reduces energy bills.
Supply section complete
The supply section comes complete with the DX coil (using R410A refrigerant) –
fitted with a solenoid control valve, freon filter, contact temperature
sensors on the liquid and gas line, and NTC sensors on the upstream and
downstream air flows. The built-in electric box is equipped with a PCB to
control the internal fan speed and to interconnect the outdoor and indoor
units, and the ducts are connected by circular plastic collars.
Characteristic curves
The following curves show the unit external static pressure at maximum fan
speed for each model. Balanced ventilation
Heat recovery with DX coil · R410A
Motorised heat recovery by-pass device automatically controlled to use fresh
air free-cooling when convenient.
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
Indoor unit | PAW-500ZDX3N | PAW-800ZDX3N | PAW-01KZDX3N | ||
---|---|---|---|---|---|
Voltage | V | 230 | 230 | 230 | |
Power supply | Phase | Single phase | Single phase | Single phase | |
Frequency | Hz | 50 | 50 | 50 | |
Air flow | m³/min | 8,3 | 13,3 | 16,7 | |
External static | pressure 1) | Pa | 90 | 120 | 115 |
Maximum current Total full load | A | 0,6 | 1,4 | 2,1 | |
Input power | W | 150 | 320 | 390 | |
Sound pressure 2) | dB(A) | 39 | 42 | 43 | |
Piping diameter Liquid | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 |
(6,35)
Gas| Inch (mm)| 1/2 (12,70)| 1/2 (12,70)| 1/2 (12,70)
Heat recovery| | Cooling| Heating| Cooling| Heating|
Cooling| Heating
Temperature efficiency| %| 76| 76| 76| 76| 76| 76
Enthalpy efficiency| %| 63| 67| 63| 65| 60| 62
Saved power summer mode or winter mode*| kW| 1,70| 4,30 (4,80)| 2,50| 6,50
(7,30)| 3,20| 8,20 (9,00)
Total / Sensible capacity| kW| 3,00 / 2,10| 2,50 / 2,70| 5,10 / 3,50| 4,40 /
4,80| 5,80 / 4,10| 5,20 / 6,70
---|---|---|---|---|---|---|---
OFF temperature| °C| 15,9| 28,0 (27,3)| 15,5| 29,6 (29,0)| 16,2| 28,5 (27,8)
OFF relative humidity| %| 90| 16 (15)| 90| 14 (13)| 89| 15 (14)
Nominal summer conditions: Outside air: 32 °C DB, RH 50%. Ambient air: 26 °C DB, RH 50%. Nominal winter conditions: Outside air: -5 °C DB, RH 80%. Ambient air: 20 °C DB, RH 50%. Cooling mode air inlet condition: 28,5 °C DB, RH 50%; evaporating temperature 7 °C. Heating mode air inlet condition: 13 °C DB, RH 40% (11 °C DB, RH 45%); condensating temperature 40 °C. DB: Dry Bulb; RH: Relative Humidity.
- Referred to the nominal air flow after filter and plate heat exchanger.
- Sound pressure level calculated at 1 m far from: ducted supply exhaust air ducted return – first air intake / service side, at normal condition.
* Tentative data.
Accessories
CZ-RTC6W | CONEX wired remote controller (non-wireless), white |
---|---|
CZ-RTC6WBL | CONEX wired remote controller with Bluetooth®, white |
CZ-RTC6 | CONEX wired remote controller (non-wireless), black |
CZ-RTC6BL | CONEX wired remote controller with Bluetooth®, black |
CZ-RTC5B | Wired remote controller with Econavi function |
PAW-RE2C4-MOD-WH | Room controller for hotel rooms, white |
PAW-RE2C4-MOD-BK | Room controller for hotel rooms, black |
PAW-RE2D4-WH | Display control for hotel rooms, white |
PAW-RE2D4-BK | Display control for hotel rooms, black |
Technical focus
- Galvanized steel self-supporting panels, internally and externally insulated
- High efficiency static cross-flow heat recovery, made by membrane with high moisture permeability, good air tightness, excellent tear, and aging resistance, structure consisting of flat and corrugated plates. Total heat exchange with temperature efficiency up to 76% and enthalpy efficiency up to 67%, also at high level during summer season
- ISO16890 ePm2,5 95% (F9 EN 779) efficiency class filter with synthetic cleanable media and COARSE 50% (G3 EN 779) pre-filter ON fresh air, COARSE 50% filter on return air intake
- Removable side panel to access filters and heat recovery in the event of scheduled maintenance
- Low consumption, low noise, high efficiency direct driven fans
- Supply section complete with DX coil (R410A) fitted with solenoid control valve, freon filter, contact temperature sensors on liquid and gas line, NTC sensors upstream and downstream of air flow
- Built-in electric box equipped with PCB to control internal fan speed and to interconnect outdoor / indoor units
- Duct connection by circular plastic collars
Interconnection to outdoor / indoor units
Electric air curtains
The Panasonic range of air curtains is designed for smooth operation and efficient performance. Air curtains produce a continuous stream of air blown from the top to the bottom of an open doorway and create a barrier that people and products can flow across, but air cannot.
Electric air curtain
-
Designed to maximize performance
High air flow upgraded 145% compared to conventional model (in the case of FY- 3009U1). -
Comprehensive product line up
1,5 m wide model added in the line up. -
Easier installation and maintenance
Simple structure for easy installation and maintenance.
| | | FY-3009U1| FY-3012U1| FY-3015U1
---|---|---|---|---|---
Width| | mm| 900| 1200| 1500
Voltage| | V| 220| 220| 220
Air flow| Hi / Lo| m³/h| 1100 / 920| 1400 / 1270| 2000 / 1800
Consumption| Hi / Lo| W| 76 / 70| 94 / 85| 131 / 110
Current| Hi / Lo| A| 0,35 / 0,32| 0,43 / 0,40| 0,59 / 0,50
Air speed| Hi / Lo| m/s| 10,50 / 8,50| 9,50 / 8,00| 10,50 / 9,50
Sound pressure| | dB(A)| 48,5 / 45,0| 48,5 / 44,5| 51,5 / 48,0
Dimension / Net weight| H x W x D| mm / kg| 900 x 231,5 x 212 / 12,0| 1200 x
231,5 x 212 / 14,5| 1500 x 231,5 x 212 / 18,0
Electric air curtain with DX coil
Designed to improve energy efficiency, minimise heat loss from a building, and
allow retailers to keep doors open to encourage customers, our air curtains
are suitable for connection to both VRF and PACi Systems.
Highly efficient heating effect
The combined air stream, which has a desirable low air current induction
factor (mixing factor), can carry the selected initial temperature effect over
long distances, and will reach the floor area while still at room temperature.
This is necessary to avoid cooling down the interior spaces.
Available in different lengths to suit requirements between 1 and 2,5 m, both
air curtains have outlet grilles that can be adjusted to five different
positions. The HS model can be installed up to a height of 3,0 m with the LS
model up to 2,7 m. The outlet grilles can be easily adjusted into five
positions to suit different installation requirements and the air filter can
be accessed without the need for specialist tools.
- High performance with EC fan motor (40% lower running costs compared to a standard AC fan motor)
- Easy Cleaning and Servicing
- Can be connected to either Panasonic VRF or PACi systems
- Drain pump for cooling operation included
- HS and LS models can be controlled via Panasonic’s range of remote internet controls
Heating capacity comparison: Electrical air curtain / Panasonic air
curtain. With the U-100PZH2E5 on the PAW-20PAIRC-LS.
Calculation method: Taking as consideration SCOP of the Panasonic combination
of 6,0.
If 100 is the energy needed for a air curtain, Panasonic air curtain will need
1/ (1-6)100=20.
The HS and LS models are ideal for connection to a ECOi or PACi system. With
simple “Plug & Play” installation, both are fitted with an EC fan motor for a
smooth operation and efficient performance. This fan guarantees 40% lower
running cost than with a standard AC fan motor. Air curtains run approximately
12 hours per day at shops, and efficient performance contributes to energy
savings.
Optimised air flow velocity
- Energy losses, no air curtain installed
- Too low velocity air curtain – air curtain not efficient
- Too high velocity air curtain – considerable turbulence, energy lost to the outside, air curtain not efficient
- Optimum results with the Frico air curtain connected to Panasonic VRF
Opening without air
curtain.
In an unprotected opening the cold air flows out and the cold storage room
becomes much too warm.
Opening with air curtain, wrong angle.
If the angle is too small the hot air is blown into the cold storage room.
Opening with air curtain, too high speed.
Excessive speed creates turbulence, which causes energy loss and increases the
cold storage temperature.
Opening with correctly adjusted air curtain.
With a correctly set air curtain unit there is a sharp separation between the
different temperature zones.
Intelligent operation
Our air curtains combine air flow and heating / cooling technology to ensure
optimum comfort and energy efficiency whilst also creating an effective
barrier between indoor and outdoor environments. Design and installation is
key to achieving the correct height / temperature settings to achieve optimum
performance. Our air curtains are designed to answer the demands of the
retail, commercial and industrial markets. Air curtain with DX coil, connected to PACi NX and PAC i
Comfort: Easy redirection of air flow by means of manual deflector.
Ease of use: Speed selector (high and low) on the unit itself.
Easy installation and maintenance: Easy installation / Compact dimensions
improve installation and positioning / Easy cleaning of grid without opening
of the unit.
Outdoor unit capacity| | | 7,1 kW| 10,0 kW| 14,0 kW|
20,0 kW
---|---|---|---|---|---|---
Air outlet height 2,7 m| | | PAW-10PAIRC-LS-1| PAW-15PAIRC-
LS-1| PAW-20PAIRC-LS-1| PAW-25PAIRC-LS-1
Cooling capacity 1)| Max| kW| 6,1| 9,7| 13,0| 17,0
Heating capacity 2)| Max| kW| 7,9| 12,0| 15,0| 19,0
Air flow| High| m³/h| 1800| 2700| 3600| 4500
Heat Exchanger| Volume| L| 1,67| 2,85| 3,94| 5,03
Electric consumption fan| 230 V / 50 Hz| kW| 0,30| 0,50| 0,60| 0,80
Current| 230 V / 50 Hz| A| 2,10| 3,10| 4,10| 5,10
Sound pressure 3)| Max| dB(A)| 65| 66| 67| 69
Air outlet height 3,0 m| | | PAW-10PAIRC-HS-1| PAW-15PAIRC-
HS-1| PAW-20PAIRC-HS-1| PAW-25PAIRC-HS-1
Cooling capacity 1)| Max| kW| 9,1| 13,0| 19,5| 23,7
Heating capacity 2)| Max| kW| 11,8| 15,8| 23,6| 27,6
Air flow| High| m³/h| 2700| 3600| 5400| 6300
Heat Exchanger| Volume| L| 1,67| 2,85| 3,94| 5,12
Electric consumption fan| 230 V / 50 Hz| kW| 0,75| 1,00| 1,50| 1,75
Current| 230 V / 50 Hz| A| 4,10| 5,50| 8,20| 9,60
Sound pressure 3)| Max| dB(A)| 66| 67| 68| 68
Common data| | | | | |
Dimension 4)| H x W x D| mm| 260 (+140) x 1000 x 460| 260 (+140) x 1500 x 460|
260 (+140) x 2000 x 460| 260 (+140) x 2500 x 460
| Air outlet height 3,0 m| kg| 55| 65| 85| 110
---|---|---|---|---|---|---
Fan type| | | EC| EC| EC| EC
Piping diameter| Liquid / Gas| Inch (mm)| 3/8 (9,52) / 5/8 (15,88)| 3/8 (9,52)
/ 3/4 (19,05)| 3/8 (9,52) / 7/8 (22,22)| 3/8 (9,52) / 7/8 (22,22)
Door width| | m| 1,0| 1,5| 2,0| 2,5
Refrigerant| | | R32| R32| R32| R32
| | | | | |
LS / PACi outdoor combination| PACi Elite|
PACi| Standard| HS / PACi outdoor combination| PACi Elite|
PACi Standard
Operation until| 40 °C| 35 °C| 30 °C| 40 °C| 35
°C| 30 °C| | Operation until| 40 °C| 35 °C| 30 °C|
40 °C| 35 °C| 30 °C
PAW-10PAIRC-LS-1| U-100| U-100| U-50| U-100| U-100| U-60| | PAW-
10PAIRC-HS-1| U-200| U-100| U-100| —| U-100| U-100
PAW-15PAIRC-LS-1| U-200| U-100| U-100| —| U-100| U-100| | PAW-
15PAIRC-HS-1| U-200| U-200| U-100| —| U-200| U-100
PAW-20PAIRC-LS-1| U-200| U-140| U-100| —| —| U-100| | PAW-20PAIRC-
HS-1| —| U-250| U-200| —| U-250| —
PAW-25PAIRC-LS-1| U-250| U-200| U-125| —| —| U-125| | PAW-25PAIRC-
HS-1| —| U-250| U-200| —| U-250| —
- Cooling capacity DX coil, air temperature in / out +27 / +18 °C, R32 and R410.
- Heating capacity condenser, air temperature in / out +20 / +33 °C, R32 and R410. In the case of lower outdoor temperatures, an outdoor model with higher capacity may be necessary.
- Measured in distance up to 5,0 m, direction factor 2, absorbing surfaces 200 m², Min / Max air flow. 4) 140 mm is the height of an electrical box if it is installed on the top. * Available with PZH2 and PZ2. PZH3 and PZ3 will be compatible from Autumn 2023.
Technical focus
- Now compatible with PACi NX Series
- Save up to 40% energy costs by use of the integrated EC fan technology (higher efficiency than conventional AC fan, soft start and longer motor duration)
- 4 length of air curtain LS and HS are available 1,0, 1,5, 2,0 and 2,5 m
- Installation height up to 3,0 m
- Outlet grilles can be adjusted in five positions, to suite different indoor and installation requirements
- Control with Panasonic remote control systems (optional)
- Direct integration to BMS via optional Panasonic interfaces
- Drip tray included in all DX air curtains
- Drain pump included
How does it work?
Stale air from the room is taken in and ejected near the door. This creates a
‘roll of air’ that shields the door area, mixing with the colder incoming air.
It then turns away from the door, back into the room and toward the intake
screen, where it is partly drawn in again. This flow of air helps to create a
barrier for heat loss yet at the same time refreshes room air
Air curtain with DX coil, connected to VRF systems
Comfort: Easy redirection of air flow by means of manual deflector.
Ease of use: Speed selector (high and low) on the unit itself.
Easy installation and maintenance: Easy installation / Compact dimensions
improve installation and positioning / Easy cleaning of grid without opening
of the unit.
Outdoor unit capacity | 4 HP | 4 HP | 5 HP | 8 HP | ||
---|---|---|---|---|---|---|
Air outlet height 2,7 m | PAW-10EAIRC-LS | PAW-15EAIRC-LS | ||||
PAW-20EAIRC-LS | PAW-25EAIRC-LS | |||||
Cooling capacity 1) | Max | kW | 6,1 | 9,7 | 13,0 | 17,0 |
Heating capacity 2) | Max | kW | 7,9 | 12,0 | 15,0 | 19,0 |
Air flow | High | m³/h | 1800 | 2700 | 3600 | 4500 |
Heat Exchanger | Volume | L | 1,67 | 2,85 | 3,94 | 5,03 |
Electric consumption fan | 230 V / 50 Hz | kW | 0,30 | 0,50 | 0,60 | 0,80 |
Current | 230 V / 50 Hz | A | 2,10 | 3,10 | 4,10 | 5,10 |
Sound pressure 3) | Max | dB(A) | 65 | 66 | 67 | 69 |
Air outlet height 3,0 m | PAW-10EAIRC-HS | PAW-15EAIRC-HS | ||||
PAW-20EAIRC-HS | PAW-25EAIRC-HS | |||||
Cooling capacity 1) | Max | kW | 9,1 | 13,0 | 19,5 | 23,7 |
Heating capacity 2) | Max | kW | 11,8 | 15,8 | 23,6 | 27,6 |
Air flow | High | m³/h | 2700 | 3600 | 5400 | 6300 |
Heat Exchanger | Volume | L | 1,67 | 2,85 | 3,94 | 5,12 |
Electric consumption fan | 230 V / 50 Hz | kW | 0,75 | 1,00 | 1,50 | 1,75 |
Current | 230 V / 50 Hz | A | 4,10 | 5,50 | 8,20 | 9,60 |
Sound pressure 3) | Max | dB(A) | 66 | 67 | 68 | 68 |
Common data | ||||||
Dimension 4) | H x W x D | mm | 260 (+140) x 1000 x 460 | 260 (+140) x 1500 x 460 | ||
260 (+140) x 2000 x 460 | 260 (+140) x 2500 x 460 | |||||
Net weight | Air outlet height 2,7 m | kg | 50 | 65 | 80 | 95 |
Air outlet height 3,0 m | kg | 55 | 65 | 85 | 110 | |
Fan type | EC | EC | EC | EC | ||
Piping diameter | Liquid / Gas | Inch (mm) | 3/8 (9,52) / 5/8 (15,88) | 3/8 (9,52) | ||
/ 3/4 (19,05) | 3/8 (9,52) / 7/8 (22,22) | 3/8 (9,52) / 7/8 (22,22) | ||||
Door width | m | 1,0 | 1,5 | 2,0 | 2,5 | |
Refrigerant | R32 / R410A | R32 / R410A | R32 / R410A | R32 / R410A |
LS / VRF outdoor combination
Operation until| 40 °C| 35 °C| 30 °C
PAW-1EAIRC-LS| U-4| U-4| U-4
PAW-15EAIRC-LS| U-6| U-5| U-4
PAW-20EAIRC-LS| U-8| U-6| U-4
PAW-25EAIRC-LS| U-8| U-8| U-5
HS / VRF outdoor combination
Operation until| 40 °C| 35 °C| 30 °C
PAW-10EAIRC-HS| U-6| U-5| U-4
PAW-15EAIRC-HS| U-8| U-6| U-4
PAW-20EAIRC-HS| U-8| U-8| U-8
PAW-25EAIRC-HS| U-12| U-10| U-8
- Cooling capacity DX coil, air temperature in / out +27 / +18 °C, R32 and R410.
- Heating capacity condenser, air temperature in / out +20 / +33 °C, R32 and R410. In the case of lower outdoor temperatures, an outdoor model with higher capacity may be necessary.
- Measured in distance up to 5,0 m, direction factor 2, absorbing surfaces 200 m², Min / Max air flow.
- 140 mm is the height of an electrical box if it is installed on the top.
* Also compatible with ECO G Series (GE3 and GF3) and Hybrid Serie.
Technical focus
- Compatible with R32 and R410A refrigerant
- Save up to 40% energy costs by use of the integrated EC fan technology (higher efficiency than conventional AC fan, soft start and longer motor duration)
- 4 length of air curtain LS and HS are available 1,0, 1,5, 2,0 and 2,5 m
- Installation height up to 3,0 m
- Outlet grilles can be adjusted in five positions, to suite different indoor and installation requirements
- Control with Panasonic remote control systems (optional)
- Direct integration to BMS via optional Panasonic interfaces
- Drip tray included in all DX air curtains
- Drain pump included
Internet control
An app added to your tablet or smartphone or via the Internet allows you to
control and manage the system remotely. There is also the option to integrate
into existing BMS systems by using other Panasonic interfaces. Rating Conditions: Cooling Outdoor +35 °C DB Indoor +27
°C DB / +19 °C WB, Discharge temperature 16 °C. All combinations under rated
conditions: Heating Outdoor +7 °C DB/+6 °C WB Indoor +20 °C DB. In case of
lower outdoor temperatures a higher capacity outdoor unit model may be
necessary. Specifications subject to change without notice. For detailed
information about ErP, please visit our websites
www.aircon.panasonic.eu or
www.ptc.panasonic.eu.
High pressure duct and 100% fresh air duct function for all ECOi and ECO
G systems
The E2 range of ducted units offers improved design flexibility for extended
duct layouts as a result of their increased external static pressures whilst
reducing energy consumption, while providing fresh air to larger
spaces. E2 type high static pressure
hide-away · R410A
High pressure duct and 100% fresh air duct function. COMPATIBLE WITH ALL
PANASONIC CONNECTIVITY SOLUTIONS. FOR DETAILED INFORMATION GO TO THE CONTROL
SYSTEMS SECTION
Type| 100% Fresh air duct function (by using Kit for 100% fresh
air)| High pressure duct
---|---|---
Indoor unit| S-224ME2E5
| S-280ME2E5| S-224ME2E5
| S-280ME2E5
| | Cooling| Heating| Cooling| Heating| Cooling|
Heating| Cooling| Heating
Capacity| kW| 22,4| 21,2| 28,0| 26,5| 22,4| 25,0| 28,0| 31,5
Input power| W| 290,00| 290,00| 350,00| 350,00| 440,00| 440,00| 715,00| 715,00
Current| A| 1,85| 1,85| 2,20| 2,20| 2,45| 2,45| 3,95| 3,95
Air flow Hi / Med / Lo| m³/min| 28,3 / — / —| 35,0
/ — / —| 56,0 / 51,0 / 44,0| 72,0 / 63,0 / 53,0
---|---|---|---|---|---
External static pressure| Pa| 200| 200| 140 (60 – 270) 1)| 140 (72 – 270) 1)
Sound pressure 2) Hi / Med / Lo| dB(A)| 43 / — / —| 44 / — / —| 45 / 43 / 41|
49 / 47 / 43
Sound power Hi / Med / Lo| dB(A)| 75 / — / —| 76 / — / —| 77 / 75 / 73| 81 /
79 / 75
Dimension H x W x D| mm| 479 x 1453 x 1205| 479 x 1453 x 1205| 479 x 1453 x
1205| 479 x 1453 x 1205
Net weight| kg| 102| 106| 102| 106
Piping diameter| Liquid| Inch (mm)| 3/8 (9,52)| 3/8 (9,52)| 3/8 (9,52)| 3/8
(9,52)
| Gas| Inch (mm)| 3/4 (19,05)| 7/8 (22,22)| 3/4 (19,05)| 7/8 (22,22)
Accessories
CZ-RTC6W | CONEX wired remote controller (non-wireless), white |
---|---|
CZ-RTC6WBL | CONEX wired remote controller with Bluetooth®, white |
CZ-RTC6 | CONEX wired remote controller (non-wireless), black |
CZ-RTC6BL | CONEX wired remote controller with Bluetooth®, black |
CZ-RTC5B | Wired remote controller with Econavi function |
CZ-RWS3 + CZ-RWRC3 | Infrared remote controller and receiver |
PAW-RE2C4-MOD-WH | Room controller for hotel rooms, white |
PAW-RE2C4-MOD-BK | Room controller for hotel rooms, black |
PAW-RE2D4-WH | Display control for hotel rooms, white |
PAW-RE2D4-BK | Display control for hotel rooms, black |
CZ-CENSC1 | Econavi energy saving sensor |
Technical focus
-
No need of rap valves for standard operation
-
100% fresh air duct function*
-
DC fan motor for more savings
-
Complete flexibility for ductwork design
-
Can be located wihtin a weatherproof housing for external installation
-
Air OFF sensor avoids cold air dumping
-
Configurable air temperature control
-
Rap valves required, see 100% fresh air duct function below.
System example
An inspection port (450 x 450 mm or more) is required at the lower side of the
indoor unit body (field supply).
100% fresh air duct function
The E2 duct with 100% fresh air duct function have exceptional discharge
temperature.
Discharge Range
| Min| Max| Default
Cooling| 15 °C| 24 °C| 18 °C
Heating| 17 °C| 45 °C| 40 °C
Plenums
Air outlet plenum (suitable for rigid + flexible duct)
| Number of exits with diameters| Model
S-224ME2E5| 1 x 500 mm| CZ-TREMIESPW705
S-280ME2E5| 1 x 500 mm| CZ-TREMIESPW706
Kit for 100% fresh air function
Kit for 2 way systems
2x CZ-P160RVK2| Rap valve kit
2x CZ-CAPE2| 3 way control PCB
CZ-P680BK2BM| Distribution joint kit
| 1x remote controller
Kit for 3 way systems
2x CZ-P160HR3| 3 way valve kit
2x CZ-CAPE2| 3 way control PCB
CZ-P680BH2BM| Distribution joint kit
| 1x remote controller
Ceiling mounted air-e nanoe X Generator
Bringing nature’s balance indoors with Panasonic’s unique nanoe™ X technology
built into the air-e.
Deodorises and inhibits certain bacteria, viruses, mould, pollens and
allergens for better indoor air quality.The air-e is a stand alone device which is an easy and simple
choice to improve indoor air quality. It can be easily installed to various
commercial projects including refurbishments.
The tested effects of nanoe™ X
Bacteria and viruses.
SARS-CoV-2: 99,9% % inhibited .
Influenza virus H1N1 subtype: 99,9 % inhibited 1) Odour.
nanoe X Generator can reduce cigarette smoke odour intensity by 2,4 levels in
12 minutes. 2)
- Novel coronavirus (SARS-CoV-2) > [Test organization] Texcell (France) [Test subject] Adhered novel coronavirus (SARS-CoV-2) [Test volume] 45 L enclosed box [Test result] Inhibited 99,9% in 2 hours [Test report] 1140-01 A1.
- Adhered virus (Influenza virus H1N1 subtype) > [Test organization] Kitasato Research Center for Environmental Science [Test subject] Influenza virus (H1N1 subtype) [Test volume] 1 000 L enclosed box [Test result] Inhibited 99,9% in 2 hours [Test report] 21_0084_1.
- Deodorisation effect for adhering odour (cigarette smoke) > [Test organization] Panasonic Product Analysis Center [Test subject] Adhered cigarette smoke odour [Test volume] Approx. 24 m³
laboratory [Test result] Odour intensity reduced 2,4 levels in 0,2 hours [Test report] 4AA33160615-N04.
Performance of nanoe™ X might differ in real life environment and is only
expected in the same room as where the unit is placed. The nanoe™ X
performance varies depending on the room size, environment and usage and it
may take several hours to reach the full effect. nanoe™ X is not a medical
device.
Deodorisation effect for adhering odour (cigarrette smoke) 3).For further details and validation data, please refer to the
following website.
https://www.panasonic.com/uk/nanoe/all/verification/evidence.html
Ceiling mounted air-e nanoe X Generator
- nanoe™ X technology (Generator Mark 1= 4,8 trillion hydroxyl radicals/sec)
- Silent operation. Whisper quiet at 25,5 dB(A)*
- Low power consumption 4 W
- Easy Installation
- Compact and modern design
* 230 V.
Model| | | | FV-15CSD1G|
---|---|---|---|---|---
Power supply| Voltage| V| 220| 230| 240
Frequency| Hz| 50| 50| 50
Air flow| | m³/h| 15| 16| 17
| CFM| 8,8| 9,4| 10,0
Consumption| | W| 4| 4| 4
Sound pressure| | dB(A)| 23,5| 25,5| 27,0
Net weight| | kg| | 1,1|
- The value of air volume, power consumption and noise are specified at static pressure 0 Pa. The value of air volume is the mean value and a tolerance of +-10% is allowed. The value of noise level is a weighted average sound pressure level, the mean value is measured by Panasonic. A tolerance of +3 dB/-7 dB is allowed. The noise is measure at 1 m apart from the left, the front and below of the tested product. Conditions of generating nanoe™ X: room temperature: about 5 °C ~ 40 °C (dew point temperature more than 2 °C), relative humidity: about 30% ~ 85%. nanoe™ X is generated using the air in the room, and its amount is subject to the temperature and humidity in the air.
One device is suitable for around 20 m² (with a ceiling height 3 m)
Ex. 3 air-e devices are required for the room size 60 m². Concentration simulator is ready
See how nanoe™ X fills space.
https://www.panasonic.com/global/hvac/nanoe/conceXntration_simulator/
Projects with nanoe™ X.
Cabinet Dental. France.
The request by a customer to manage the indoor air quality in order to ensure
irreproachable hygiene and odour control.
Mercat d’autors shop. Spain.
The nanoe™ X was chosen to ensure a cleaner air supply at a food market.
Heat recovery ventilation unit
The heat recovery ventilation unit is design not only to provide a good indoor air quality, but it is also designed to recover heat that would otherwise be lost throughout ventilation. These heat recovery ventilation systems are used to assist in the retention of heat.
-
High indoor air quality
The unit is designed to provide fresh filtered air into the home, while keeping a high thermal comfort. -
Energy saving
Most of the energy from the exhausted air is used to precondition the incoming air, leading to lower heating requirements in the building. -
Space saving
The compact ventilation unit can be installed over the DHW square tank or the Aquarea All in One Compact indoor unit for an space-saving solution. -
Better user interface
The Residential ventilation unit and the Aquarea Heat Pump can be controlled with one single userfriendly controller.
Combine the Residential ventilation unit with Panasonic Aquarea for an space saving and highly efficient solution for heating, cooling, ventilation and DHW.
| |
---|---|---
Heat Recovery Ventilation + Aquarea All in One Compact| Heat Recovery
Ventilation + DHW Square Tank + Aquarea Mono-bloc| Heat Recovery Ventilation +
DHW Square Tank + Aquarea Bi-bloc
Heat recovery ventilation unit| PAW-A2W-VENTA-R| PAW-A2W-
VENTA-L
---|---|---
Nominal air flow rate| m³/h| 204 @ 50 Pa
Maximum air flow rate| m³/h| 292 @ 100 Pa
SPF| | 1,24 @ 204 m³/h
Heat exchanger rotor drive type| | Variable speed
Exchanger type| | Rotating
Heat recovery efficiency| | 84%
Power supply| V / Hz| 230 / 50 / 1 phase
Power consumption| W| 176
Energy class, basic unit| | A
Energy class, unit with local control on demand| | A
Noise level| dB(A)| 40
Dimension (H x W x D)| mm| 450 x 598 x 500
Weight| kg| 46
Mounting position| | Vertical
Supply side| Right| Left
Duct connections| mm| DN125
Filter class, supply air| | F7/ePM1 60%
Filter class, extract air| | M5/ePM10 50%
Minimum outdoor temperature| °C| -20
* Heat recovery efficiency according to EN 13141-7.
** Heat recovery ventilation unit is produced by Systemair.
Accessories
PAW-VEN-FLTKIT | Supply and extract filters kit |
---|---|
PAW-VEN-ACCPCB | Optional PCB for additional functions |
PAW-VEN-DPL | HRV touch control panel. White frame (cable must be ordered |
separately)
PAW-VEN-CBLEXT12| Cable with plug for electrical connection between unit and
control panel, type CE and CD (12 m)
PAW-VEN-DIVPLG| Twin plugs for installation of several control panels type CD
or CE for one unit
PAW-VEN-DPLBOX| HRV touch control panel wall-mounted kit
PAW-VEN-S-CO2RH-W| CO2 RH wall-mounted sensor
PAW-VEN-S-CO2-W| CO2 wall-mounted sensor
PAW-VEN-S-CO2-D| CO2 duct sensor
PAW-VEN-WBRK| Wall bracket kit for stand-alone installation on the wall
PAW-VEN-HTR06| Electrical duct heater 0,6 kW (includes relay)
PAW-VEN-HTR12| Electrical duct heater 1,2 kW (includes relay)
Main features of the residential ventilation unit
- Designed for areas up to approximately 140 m²
- High energy-efficiency rotary heat exchanger with EC – technology fans
- Moisture transfer function to minimize condensation in supply air during wintertime
- The built in humidity sensor in extract air can be used for demand control
- Control via touch display and Startup Wizard for easy commissioning
- Modbus communication via RS-485
- Option to control an Aquarea H Generation onwards heat pump from PAW-A2W-VENTA control panel (PAW-AW-MBS-H and PAW-VEN-ACCPCB required)
Control user-friendly interface
All settings and features accessible via a control panel, integrated into the
front cover. The option for connecting one or more external control panels is
available.
- Color touch screen with a user-friendly interface
- MANUAL and AUTO mode or choose preferred settings from the preconfigured user modes
- If Aquarea H and J Generations heat pumps are connected with PAW-A2W-VENTA, the heat pump control options appear on the home screen in a separate tab
New counter flow ventilation
Controlled mechanical ventilation ensures the supply of fresh air inside a building in order to guarantee a good indoor air quality.
Universal mounting compact unit (Z).
- Suitable for small and medium size apartments, with nominal air flow up to 200 m³/h
- Universal mounting (horizontal or vertical)
Horizontal mounting unit (H).
- Suitable for single family houses, with nominal air flow rates up to 350 m³/h
- Horizontal mounting
- Easily accessible lower panel for maintenance and inspection
Vertical mounting unit (V).
- Suitable for single family houses, with nominal air flow rates up to 350 m³/h
- Vertical mounting
- Easily accessible front panel for maintenance and inspection
Counter flow ventilation| PAW-| VENTX10Z| VENTX15Z|
VENTX20H| VENTX20V| VENTX30H| VENTX30V| VENTX40H|
VENTX40V
---|---|---|---|---|---|---|---|---|---
Air flow| Nominal / Max| m³/h| 91 / 130| 147 / 210| 109 / 155| 112 / 170| 210
/ 300| 210 / 300| 238 / 340| 266 / 380
Static pressure| Nominal / Max| Pa| 50 / 100| 50 / 100| 50 / 100| 50 / 100| 50
/ 100| 50 / 100| 50 / 100| 50 / 100
Type of HEX| | | Counter flow HRV| Counter flow HRV| Counter flow HRV| Counter
flow HRV| Counter flow HRV| Counter flow HRV| Counter flow HRV| Counter flow
HRV
Recovery efficiency| | %| 87| 85| 86| 86| 85| 86| 89| 87
Energy class| | | A| A| A| A| A| A| A|
A
| Voltage| V| 230| 230| 230| 230| 230| 230| 230| 230
Power supply| Phase| | Single phase| Single phase| Single phase| Single phase|
Single phase| Single phase| Single phase| Single phase
| Frequency| Hz| 50| 50| 50| 50| 50| 50| 50| 50
Power consumption| Nominal| W| 80| 140| 110| 110| 180| 180| 350| 350
Sound Power LWA| | dB(A)| 48| 51| 49| 48| 50| 50| 52| 51
Dimensions| H x W x D| mm| 255 x 580 x 580| 255 x 580 x 580| 260 x 480 x 800|
510 x 430 x 625| 295 x 600 x 795| 590 x 575 x 785| 290 x 650 x 1150| 590 x 735
x 785
Weight| | kg| 19| 19| 25| 32| 30| 38| 38| 42
Mounting position| | | Horizontal / Vertical| Horizontal / Vertical|
Horizontal| Vertical| Horizontal| Vertical| Horizontal| Vertical
Filter class| | | ePM1 80%| ePM1 80%| ePM1 80%| ePM1 80%| ePM1 70%| ePM1 70%|
ePM1 70%| ePM1 70%
Duct connection| | mm| 160| 160| 160| 160| 160| 160| 160| 160
* Produced by Sinergia.
Accessories
PAW-VEN-CTRLB| Digital remote control (black). Integrated air quality,
temperature and humidity sensors
---|---
PAW-VEN-CTRLW| Digital remote control (white). Integrated air quality,
temperature and humidity sensors
PAW-VEN-HTR05| Electrical duct heater 0,5 kW, DN125 mm
PAW-VEN-HTR10| Electrical duct heater 1,0 kW, DN160 mm
PAW-VEN-FLT1| Spare F7 filter kit (2 pcs) for models 10Z, 15Z, 20H and 20V
PAW-VEN-FLT2| Spare F7 filter kit (2 pcs) for models 30H and 30V
PAW-VEN-FLT3| Spare F7 filter kit (2 pcs) for models 40H
PAW-VEN-FLT4| Spare F7 filter kit (2 pcs) for models 40V
PAW-VEN-ACFLT1| Activated carbon filter (1 pc) for models 10Z, 15Z, 20H and
20V
PAW-VEN-ACFLT2| Activated carbon filter (1 pc) for models 30H and 30V
PAW-VEN-ACFLT3| Activated carbon filter (1 pc) for models 40H
PAW-VEN-ACFLT4| Activated carbon filter (1 pc) for models 40V
Counter flow ventilation units are equipped with two fans to supply and extract air. A cross-flow heat exchanger recovers the energy contained in the extracted air and transfers it to the supplied air. This significantly reduces the building’s energy consumption, while at the same time keeping a good quality of the indoor air.
Balanced ventilation
- Suitable for single family houses or apartments with low energy requirements
- High-efficiency sensible heat recovery, thanks to polypropylene counter-flow heat exchanger with large exchange surface and low pressure drop
- High comfort and quiet operation, by using brushless fans with electronic motor and modulating control
- Highly efficient air renewal and filtration, with 80% ePM1 filters
- 3 unit types: compact universal mounting (Z), horizontal mounting (H) and vertical mounting (V)
- Compact dimensions for simplified installation and panel easily accessible for maintenance and inspection
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic Marketing Europe GmbH.
To find out how Panasonic cares for you, log on to:
www.panasonic.co.uk/aircon
General requests: Email: uk-aircon@eu.panasonic.com
Sales administration team:
Email: uk-aircon-salesadmin@eu.panasonic.com
Technical service team:
Email: uk-aircon-tech@eu.panasonic.com
UK Office : +44 (0) 1707 378670
Panasonic Heating & Ventilation Air-Conditioning UK Ltd.
Registered Office: Ground Floor, Building 3, Albany Place, Hyde Way, Welwyn
Garden City, Hertfordshire AL7 3BT
Company Registration: 02371708
Do not add or replace refrigerant other than the specified type. Manufacturer
is not responsible for the damage and deterioration in safety due to usage of
the other refrigerant.
The outdoor units in this catalogue contains fluorinated greenhouse gases with
a GWP higher than 150.
www.eggeassociats.net
UK -RA C-C A CPLS T0323/01