HIKVISION DS-KV9503-WBE1Video Intercom Villa Door Station User Guide
- June 17, 2024
- Hikvision
Table of Contents
**HIKVISION DS-KV9503-WBE1Video Intercom Villa Door Station User Guide
**
Diagram References
Appearance
- IR Light
- Microphone
- IR Light
- Camera
- Touch Screen
- Button
- TF Card Slot (Reserved)
- Debugging Port
- Wiring Terminal
- Tamper
- Network Interface
- Loudspeaker
Terminal and Wiring
NC: Door Lock Relay Output (NC)
NO: Door Lock Relay Output (NO)
COM: Common Interface
AIN1 &AIN2: For the access of Door Contact
AIN3 &AIN4: For the access of Exit Button
485-: RS-485 Interface
485+: RS-485 Interface
12 VDC: Power Supply Input
GND: Grounding
Refer to User Munual for more details about terminal and wiring.
Installation Accessory
-
Mounting Template
-
Mounting Plate
Note: The dimension of the mounting plate is 160.3 mm × 67.4 mm × 2 mm.
Installation
Note: Video intercom villa door station supports flush mounting and surface mounting.
Before You Start
- Mounting template is required for surface mounting.
- Make sure the device in the package is in good condition and all the assembly parts are included.
- The power supply of the indoor station is 12 VDC. Make sure your power supply matches your villa door station.
- Make sure all related equipments are power-off during the installation.
- Check the product specification for the installation environment.
Surface Mounting with Gang Box
Gang box is not supplied.
- Make sure the gang box is installed on the wall.
- Secure the mounting plate on the gang box with the four supplied screws (SC-KA4X25). Remove the back cover and route the cable through the cable hole, wire the cables and insert the cables in the gang box.
- Align the device with the mounting plate, and secure the device on the mounting plate with 1 supplied screw (SC-M3X8NL-SUS316L-GB78).
Surface Mounting without Gang Box
- According to the datum line on the mounting template, stick the mounting template on the wall or other surface, 1.45 meters higher than the ground.
- Drill holes on the wall or other surface according to the instructions on the mounting template.
- Secure the mounting plate on the gang box with the four supplied screws (SC-KA4X25). Remove the back cover and route the cable through the cable hole, wire the cables and insert the cables in the gang box.
- Align the device with the mounting plate, and secure the device on the mounting plate with 1 supplied screw (SC-M3X8NL-SUS316L-GB78).
Configuration
Quick Operation
After activating the device, the quick configuration page will pop up automatically.
-
Select language and tap Next.
-
Set password reset method and tap Next.
Enter the Reserved Email address, then you can reset the admin password by email.
Tap Change to Security Question. Select 3 security questions from the list and enter the answers, then you can reset the password by answering security questions. -
Set network parameters and tap Next.
Set the IP address, Subnet Mask and Gateway manually.
Enable DHCP, the device will get network parameters automatically. -
Enable the cloud service functions and create a verification code. Tap Next.
-
Tap Next to finish wizard.
Add User
You can add user after activating the device.
Steps:
- On the menu, tap User to enter the settings page.
- Tap + to enter the add user page.
- Set Employee No., Name, Room No. and Floor No..
- Add Face.
- Add Card.
- Set User Role as Normal User or Administrator
Unlock Door
Unlock by Face
Face forward at the camera to unlock.
Note: Make sure that you have added your face picture to the device.
Unlock by Presenting Card
Present the card on the card reading area to unlock.
Note: Make sure you have issued the card to the device.
Installation Positions
Recommended Installation Height (The distance between the camera and the
ground):
1.4 m to 1.6 m
The FOV of the camera is : Horizontal: 88°, Vertical: 44°.
The highest visual height and lowest visual height of the camera is shown as
picture.
Refers to Video Intercom Villa Door Station User Manual (scan the QR code) for
details.