VEVOR SCA-30NS Sauna Heater User Manual

June 17, 2024
VEVOR

VEVOR SCA-30NS Sauna Heater

Product Information

Specifications

  • Model: SCA-30NS, SCA-45NS, SCA-60NS, SCA-80NS, SCA-90BW
  • Power Supply(V/Hz): 220/60
  • Power(Kw): SCA-30NS – 3Kw, SCA-45NS – 4.5Kw, SCA-60NS – 6Kw, SCA-80NS – 8Kw
  • Sauna room capacity: Minimum – 2 persons, Maximum – 12 persons
  • Suggestion heating time: SCA-30NS – 20-40 minutes, SCA-45NS – 20-40 minutes, SCA-60NS – 30-50 minutes, SCA-80NS – 30-50 minutes

Product Usage Instructions

Before Installation:

Check that the following parts are included in the packaging:

  1. Sauna heater
  2. Connectors x 3 (Pre-installed inside Junction box)
  3. Bracket screws x 4 (640mm 2pcs, 616mm 2pcs)
  4. Fork terminal x 3

WARNING:

  1. Electrical shock hazard – To avoid electrical shock hazards, all installations and relevant services shall be performed by qualified personnel.
  2. Sauna bath time should be less than half an hour. Bathing too long may cause the heart to beat too fast, heartache, and feeling weak or dizzy. Users should stop sauna bath immediately as soon as the above symptoms occur.
  3. A sauna bath may cause tension of bathers. Thus, those who have one of the symptoms as below should take a sauna bath under the direction by a physician:
    • A. Being pregnant
    • B. Having heart disease
    • C. Having high blood pressure
    • D. Having circulation system disease
    • E. After drinking
    • F. After taking medicine
    • G. Diabetes
    • H. Not feeling well

Installation:
Noted: the upper screws must be fastened tight, and the minimum distance between the screw head and the wall is 3mm.

Guard Rail:

Please follow the minimum distance requirements in Figure 6 if a guardrail is desired for the heater.

Temperature Control:
The temperature could be controlled by the thermostat inside the sauna heater (figure 3). The thermostat dial shows a rising heat scale. Find the sauna temperature which suits you best (Usually 158-176°F / 70-80°C). The sauna room can reach a preset temperature in 30 to 60 minutes, depending on the size of the sauna room and the power of the sauna heater.

Power Switch (Timer):
A. The power switch should be turned off when leaving the sauna room, as it is the main power control of the sauna room.
B. To set the time for immediate start: Turn the timer knob full clockwise, the length of the sauna is set for 180 minutes.

FAQ:

  • Q: Where can I get technical support or help with product questions?
    A: You can contact us at CustomerService@vevor.com for technical support or product questions.

  • Q: How long should I take a sauna bath?
    A: Sauna bath time should be less than half an hour. Bathing too long may cause the heart to beat too fast, heartache, and feeling weak or dizzy. Users should stop sauna baths immediately as soon as the above symptoms occur.

  • Q: Can pregnant women use the sauna heater?
    A: Pregnant women should take a sauna bath under the direction by a physician. Please consult a doctor before using the sauna heater.

  • Q: What is the suggested heating time for each sauna heater model?
    A: The suggested heating time varies for each model. Please refer to the specifications section for the suggested heating time for each model.

We continue to be committed to providing you tools with at competitive prices. “Save Half”, “Half Price” or any other similar expressions used by us only represent an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and do not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are saving half in comparison with the top major brands.

NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us: at CustomerService@vevor.com

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

BEFORE INSTALLATION

Parts
Check that the following parts are included in the packaging:

  1. Sauna heater
  2. Connectors x 3 (Pre-installed inside Junction box)
  3. Bracket screws x 4 (640mm 2pcs, 616mm 2pcs)
  4. Fork terminal x 3

WARNING

  1. Electrical shock hazard——To avoid electrical shock hazards, installations, and relevant services shall be performed by qualified personnel.

  2. Sauna bath time should be less than half an hour. Bathing too long may cause the heart to beat too fast, heartache, and feeling weak or dizzy. Users should stop sauna baths immediately as soon as the above symptoms occur.

  3. Sauna bath may cause tension of bathers. Thus, those who have  one of the symptoms as below should take a sauna bath under the direction by the physician:
    A. Being pregnant B. Having heart disease C. Having high blood pressure D. Having circulation system disease E. After drinking
    F. After taking medicine G. Diabetes H. Not feeling well

  4. Children must be in the company of adults during sauna baths.

  5. Risk of scald: Must not touch or move the sauna heater during heating. Stay at least 30cm away from the hot heater.

  6. Use ordinary drinking water only.
    It may damage the heating elements when water with other materials is poured into the stone compartment, which is beyond our guarantee.

  7. Odors may occur during the first sauna bath as the Anti-rust oil for heating elements, which will disappear after the sauna heater powers on when opening the sauna door for about 10-15mins.

INSTALLATION

Install the sauna heater onto the wall using the screws provided with the heater, according to the minimum safety distances and volumes indicated in Table 1 and Figure 1, or on the tech plate of the heater.

  • The heater can be installed inside the sauna room with a minimum height of 1900mm.(Figure 1C)
  • The wall behind the heater is not allowed to be covered by materials like asbestos cement, asbestos board, and so on, because this sort of covering layer could cause high temperatures and a risk of burn.
  • Must use qualified materials for the walls and ceiling.

Noted : the upper screws must be fastened tight, the minimum distance between the screw head and the wall is 3mm.

GUARD RAIL
Please follow the minimum distance requirements in figure 6 if a guardrail is desired for the heater.

TEMPERATURE CONTROL

The temperature could be controlled by the thermostat inside the sauna heater (figure 3).The thermostat dial shows a rising heat scale. Find the sauna temperature which suits you best(Usually 158-176℉/70-80℃). The sauna room can reach on a preset temperature in 30 to 60 minutes, it depends on the size of the sauna room and the power of the sauna heater.

POWER SWITCH(TIMER)

  • A. The power switch should be turned off when leaving the sauna room, as it is the main power control of the sauna room.
  • B. To set the time for immediate start: Turn the timer knob full clock-wise, the length of the sauna is set for 180 minutes.

Specifications

  Power   Sauna room Suggestion
Model Supply(V

/Hz)

| Power(K w)| Volume(m³)| heating time
Min| Max| (28-70℃)
SCA-30| 220/60| 3| 2| 4| 20-40min
NS|  |  |  |  |
SCA-45|  | 4.5| 3| 6| 20-40min
NS|  |  |  |  |
SCA-60|  | 6| 5| 9| 30-50min
NS|  |  |  |  |
SCA-80|  | 8| 8| 12| 30-50min
NS|  |  |  |  |
SCA-90|  | 9| 9| 13| 30-50min
BW|  |  |  |  |
The above suggested heating time should be achieved, including but not limited to these:

1.  Room thermometer installed opposite to the sauna heater, closing to the ceiling.

2. The sauna room is installed indoors with insulation for diffusion prevention purposes.

3.  Temp knob adjusts to the Max.

CONNECTION OF ELECTRICITY SUPPLY CABLE

  1. Only the qualified electrician can finish the connection of the heater’s cables. You must obey electrical codes to finish the installation. Rubber-insulated cables are suggested as the connection cables from main supply to the sauna heater.
  2. The junction box inside the sauna heater must be of a hermetic, splashing-proof type, also including a 7mm diameter drainage hole to prevent moisture and condensation. The junction box should be less than 500mm over the floor.

VENTILATION

  • To have a smooth sauna bath, there should be a proper mixing of hot and cold air inside the sauna room. Another reason for ventilation is to draw air around the sauna heater and move the heat to the farthest part of the sauna room.
  • The inlet vent with a diameter of more than 6cm should be installed directly below the sauna heater.
  • The outlet vent should be installed diagonally opposite to the inlet, it’s suggested to place it under the platform inside the sauna room as far as possible from the inlet vent. The diameter of the outlet vent should be twice as big as the inlet, it may be installed far away the floor and under the bottom of the upper bench.

SAUNA STONES
Its recommended that all sauna stones should be rinsed to remove any stains or dust. The largest ones should be loaded at the bottom. Do not load the stones too tight to block air circulation through the sauna heater. New ones should be loaded when the stones get broken or crumbling. Load sufficient sauna rocks(10-15kgs) into the sauna heater after finishing the installation of the sauna heater and controller.
ATTENTION : Sauna rocks must be of the best quality because the temperature inside the sauna heater is extremely high. Rocks of inferior quality can’t withstand heat and they may be easily broken or crumbling because of the huge heat changing, which may damage heating elements. These stones may counteract the heat circulation because they are easily oxidized, and the sauna heater may be damaged while the stone is heated or being poured water to make vapors.

GUARANTEE

  1. The control panel is under a year guarantee.
  2.  The main body of the sauna heater is under a year’s guarantee.
  3. The following situations are not guaranteed:
  4. Installation or disassembly of the inside structure by unprofessional personnel;
  5. Supply voltage fluctuation range>±10%;
  6. Unqualified rocks on the sauna heater’s operation;
  7. Installation without following the dimension instructions inside the manual.

TROUBLESHOOTING

Address : Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai
Imported to the USA: VEVOR STORE INC, 9448 RINCHMOND PL #E RANCHO CUCAMONGA, California, 91730 United States of America Made In China
Technical Support and E-Warranty Certificate www.vevor.com/support