Product Information
Specifications
- Model: LARK M2
- Version: Mobile and Camera
- Volume Adjustment: Mobile version – through the APP (iOS version supports 3-level adjustments, Android version supports 6-level adjustments); Camera version – through the knob on the RX (clockwise to increase volume, counterclockwise to decrease volume)
- Pairing Mode: Mobile version – TX (long press side yellow button for 6 seconds), RX (long press bottom yellow button for 3 seconds); Camera version – TX (long press side yellow button for 6 seconds), RX (press and hold M button on lower left side for 3 seconds)
- Upgrade Method: Mobile version – via the LarkSound APP; Camera version – via computer’s host software after proper pairing
- Charging: Camera version RX – LED stays solid orange when not fully charged (requires an upgrade to V2.1.0.23 to fix charging logic bug)
FAQ
Operations FAQ
-
How to turn on LARK M2’s ENC function?
- Mobile version: tap the yellow button on the side of the TX, or tap the yellow button at the bottom of the RX.
- Camera version: tap the yellow button on the side of the TX.
-
How to pair?
- Mobile version:
- For TX, long press the side yellow button for 6 seconds when the power is off to enter pairing mode (quickly flashing blue light);
- For RX, long press the bottom yellow button for 3 seconds to enter pairing mode (quickly flashing blue light);
- TX and RX need to enter the pairing mode at the same time. Steady blue light indicates pairing is successful.
- Camera version
- For TX, long press the side yellow button for 6 seconds when the power is off to enter pairing mode (quickly flashing blue light);
- For RX, press and hold the M button on the lower left side for 3 seconds to enter pairing mode;
- TX and RX need to enter the pairing mode at the same time. Steady blue light indicates pairing is successful
-
How to upgrade?
-
Mobile version
-
A: The mobile version can be upgraded via the LarkSound APP.
-
Camera version
A: The camera version is upgraded via the computer’s host software after pairing TX and RX properly. -
Connect the RX to your computer using the provided USB cable;
-
Open the host software on your computer, and the software will automatically identify the microphone driver. Once identification is successful, click on “upgrade”;
-
During the upgrade process, the LED on TX and TX will display a steady pink light. Wait for the progress bar on the host computer to complete. When finished, the LED on TX and RX will return to the former color, indicating a successful upgrade.
-
-
How to adjust the voice volume?
- A: The camera version adjusts the output volume through the knob on the RX. Turn clockwise to turn the volume up and counterclockwise to turn the volume down. The 3 LEDs below show the current volume level. The mobile version adjusts the output volume through the APP. The iOS version of the APP supports 3-level adjustments while the Android version supports 6-level adjustments.
General FAQ
- The camera version RX cannot be fully charged and the LED stays solid orange?
- A: This is a charging logic bug. The latest version has been optimized to address this problem. Upgrading to V2.1.0.23 can solve it.
- When the LARK M2 camera version is connected to the VenusLiv Camera, only one microphone has sound.
- A: When the RX is connected to the VenusLiv Camera via a 3.5mm TRS to TRS cable, you need to switch to mono mode for audio reception. Just press the M button on the side of the RX, and the LED below will switch to a steady green light.
- There are no “Strong” and “Weak” options in the LarkSound App
- 1A: You need to turn on the ENC function first and then select strong or weak noise cancellation in the App