AEMC 6422 Calibration Checker For Ground Tester User Manual
- June 17, 2024
- AEMC
Table of Contents
AEMC 6422 Calibration Checker For Ground Tester
Product Information
Specifications:
- Product Name: Calibration Checker For Ground Tester Models 6422/6424
- Test Resistances: 25 and 125
- Compatible Models: Model 6422 and Model 6424
- Manufacturer: AEMC
- Website: www.aemc.com
Product Usage Instructions
Step 1: Inserting the Calibration Checker
- Locate the instrument’s terminals labeled H-S-E.
- Take the Calibration Checker and insert it into the instrument’s terminals.
- Ensure each pin on the Calibration Checker is inserted into its corresponding terminal, matching H to H, S to S, and E to E.
Step 2: Checking Accuracy
Once the Calibration Checker is properly inserted, you can proceed with
checking the accuracy of your Model 6422 or 6424.
- Select the desired test resistance (25 or 125) on the Calibration Checker.
- Refer to your instrument’s user manual to determine the appropriate procedure for performing accuracy checks.
- Follow the instructions provided in your instrument’s user manual to complete the accuracy check process.
Frequently Asked Questions (FAQ)
-
Q: What is the purpose of the Calibration Checker?
A: The Calibration Checker is used to check the accuracy of your Model 6422 or 6424 Ground Tester. -
Q: How many test resistances does the Calibration Checker provide?
A: The Calibration Checker provides two test resistances – 25 and 125. -
Q: Where can I find technical and sales assistance for this product?
A: For technical problems, starting assistance, configuration help, or general operation support, you can contact our technical support team through the following options:- Phone: 508-698-2115
- Fax: 508-698-2118
- E-mail: techsupport@aemc.com
- Website: www.aemc.com
HOW TO USE
The Calibration Checker provides two test resistances (25Ω and 125Ω) to check the accuracy of your Model 6422 or 6424.
- Insert the Calibration Checker into the instrument’s terminals. Ensure each pin is inserted in its corresponding terminal (H-S-E).
- Observe the reading. This should be 125Ω ± 2.7Ω.
- Press TEST. After a few moments, the reading appears. This should be 25Ω ± 0.35Ω.
Technical and Sales Assistance
If you are experiencing any technical problems, or require any assistance with starting, configuring, or operating your instrument, please call, mail, fax, or e-mail our technical support team:
Chauvin Arnoux® , Inc. d.b.a. AEMC® Instruments
Phone: 800-343-1391
508-698-2115
Fax: 508-698-2118
E-mail: techsupport@aemc.com
www.aemc.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>