Aseptico ALU-40LED Portable Dental Lamp Instruction Manual

June 17, 2024
Aseptico

Aseptico ALU-40LED Portable Dental Lamp Instruction Manual

INSTRUCTION

INFORMATION CONCERNING THE ACCURACY AND PRECISION OF THIS PRODUCT MAY BE OBTAINED UPON REQUEST BY CONTACTING ASEPTICO AT THE ADDRESS SHOWN ON THIS PAGE .

To prevent injury to people and damage to property, please heed relevant warnings and remarks. They are marked as follows:

WARNING: Serious injury or death may result if ignored.

CAUTION: Damage to property or the environment may result if ignored.

NOTE: Important additional information and hints.

Your new Aseptico ALU-40LED Lamp is one of the finest operating lights available to the dental and medical professions. The ALU-40LED uses an LED light source which provides brilliant white light, reduced power consumption, and longer operating life. The universal voltage input Lamp operates from 100VAC to 240VAC, 50 and 60Hz, and it provides an auxillary DC input that allows 12V and 24V battery operation in the field. The ALU-40LED features a compact lamp head with adjustable intensity and spotlight aperature controls, flexible gooseneck, telescoping tripod stand and padded carrying case.

Congratulations!

This System is engineered to provide many years of reliable service. Please read the instructions provided in this manual to receive the best and longest service from your Aseptic equipment.

Separate manuals may be provided to cover the operation and maintenance of other accessories for your unit.

PACKAGE CONTENTS

  • Portable Dental Lamp Assembly, PN: 120369
  • Color Filter, PN: 461974 (For use with light-activated composites.)
  • Two 0.160A Spare Fuses, PN: 830046
  • One Each 110V Power Cord, PN: 840107, and 220V Adapter, PN: 840115
  • Soft Padded Carrying Case, PN: 410084
  • Operation and Maintenance Manual, PN: 420841
  • Setup Guide, PN: 420884

PURCHASED SEPARATELY

  • DC Battery-Power Clip Assembly (Optional), PN : AA-40DC-BC
  • 12Vdc Automobile Power Adapter Assembly (Optional), PN : AA-40DC-LP
  • Color Filter 5-Pack (Optional), PN : AA-40FK
  • Lens Replacement Kit (Optional), PN: AA-40LK, Includes:
    • Fresnel Lens, PN: 461935
    • Color Filter, PN: 461974
    • Lens Cover, PN : 461936
    • Torx Key, PN: 490140 (For removing Fresnel Lens)
    • Three (3) Torx Screws, PN: 510727 (For mounting Fresnel Lens)

To prevent injury to people and damage to property, please heed relevant warnings and remarks. They are marked as follows:

WARNING: Serious injury or death may result if ignored.
CAUTION: Damage to property or the environment may result if ignored.
NOTE: Important additional information and hints.

SAFETY PRECAUTIONS

Aseptico accepts no liability for direct or consequential injury or damage resulting from improper use, arising in particular through the non-observance of the operating instructions, or improper preparation and maintenance of this product.

  • CAUTION: Use for intended purposes only. Failure to observe the operating instructions may result in the patient or user suffering serious injury or the product being damaged, possibly beyond repair. Before using this product, make sure that you have studied and understood the operating instructions.
  • CAUTION: Use of other Lamp filters or accessories from third-party manufacturers is the sole  responsibility of the user.
  • CAUTION: All repairs to the LED Assembly, Boom Arm, and Power Supply are to be performed by authorized Aseptico service personnel only.
  • WARNING: Do not install where there is a risk of an explosion. The ALU-40LED is not intended for operation in the presence of flammable anesthetics or gases.
  • CAUTION: Connect AC power supply mains cable to a properly grounded outlet only.
  • CAUTION: The ALU-40LED Lamp is sensitive to shock and may be damaged if dropped or impacted against a hard surface.
  • WARNING: Do not disassemble or alter the Lamp’s LED, Boom Arm, or Power Supply sub assemblies.
  • CAUTION: It is recommended to always have the patient wear darkened eyewear during dental procedures. Avoid looking directly into the LED when Lamp is turned on.
  • CAUTION: If the Lens Cover and/or acrylic Fresnel Lens on the Lamp Head needs to be cleaned, use reagent-grade isopropyl alcohol, professional lens cleaning solution, or de-ionized water with a small amount of dish soap – do not use other solvents as they might adversely react with the Lens materials.

SETTING UP THE UNIT

**Fig. 1 – System Components

**

  1. Remove the ALU-40LED Lamp from its carrying case. Unfold the tripod legs to a horizontal position. Loosen the pedestal adjustment knob and slide the legs to the bottom of the post (see Figure 1). Secure legs in place by firmly tightening the knob. Set Lamp Assembly on a stable, level floor surface.
  2. Loosen the handgrip on the center post (see Figure 1) and raise the post to the desired height. Tighten the handgrip to secure post in place. Loosen the boom adjustment handle and extend boom to desired length and/or pivot the lamp head to the desired operating position. Tighten handle to secure the boom in place.
  3. Attach power cord to receptacle on bottom of power supply housing (see Figure 2, page 3) and plug cord into a grounded electrical outlet. NOTE: The ALU-40LED Lamp features auto-sensing, global voltage compatibility for 100VAC, 115VAC, 230VAC, and 240VAC at 50Hz and 60Hz. The fuses provided are correct for these line voltages. NOTE: A USA style 110V power cord and 220V adapter are shipped with the unit. Power plug adapters for the specific country of usage may need to be purchased separately.

Optional DC Power:

If the power source is 12VDC or 24VDC, use the optional DC Battery Clip or Adapter Assemblies (see Figure 3) to connect to the DC source. Insert the Assemblies’ Power Plugs into the DC Power Jack located on the bottom of the power supply housing (see Figure 2, page 3).

NOTE: When attaching the optional DC Battery Clips to the battery, connect the red cable clamp to the positive (+) terminal, and the black clamp to the negative (-) terminal.

OPERATION

After the ALU-40LED Lamp has been set up, the unit is ready to operate:

  1. Ensure that the protective Lens Cover is mounted onto the front of the Lamp Head (see Figure 4).
    IMPORTANT: If applying light-activated composites, it is recommended that the supplied Color Filter, PN: 461974, be used to filter the light from the ALU-40LED Lamp. To install the Filter, remove the Lens Cover and place the Filter against the inside of the Cover (see Figure 5, page 6). Center the Filter so that it completely covers the transparent shield on the Cover. Replace the Lens Cover.

  2. Turn On/Off switch located on bottom of power supply housing to On (—) position (see Figure 2, page 3).
    WARNING:
    Avoid looking directly into LED lamp. Protect patient with darkened eye wear when directing light near patient’s eyes.

  3. Adjust light intensity and spot size by rotating the two adjustment rings on the Lamp Head (see Figure 4):

    a) LED Intensity Adjustment Ring : Provides variable brightness control.
    When viewed from the rear of the Lamp Head, rotate Ring clockwise to increase lamp intensity, or counterclockwise to decrease intensity. The intensity adjustment range is from 0% to 100%. NOTE: The total adjustment range of the Intensity Ring covers approximately 90° of rotation — do not attempt to force the Ring past the
    stops at each end of this range.
    b) LED Aperture Adjustment Ring:
    Allows user to select from seven different beam aperture sizes. When viewed from the rear of the Lamp Head, rotate the Ring counterclockwise to increase beam width, and clockwise to decrease width. NOTE: When the Aperture Ring is rotated continuously in one direction, the Lamp will repeatedly cycle through the seven aperture sizes.

MAINTENANCE

NOTE : The Lens Cover, Color Filter, Fresnel lens, Vertical Stand, Fuses, and Power Cords are the only user replaceable parts on the ALU-40LED Lamp. All other Lamp components, such as the LED Assembly, Power Supply, and Boom Assembly are not field serviceable and must be returned to Aseptico if repairs are required.

  1. FRESNEL LENS REPLACEMENT:
    Procure the optional Fresnel Lens Replacement Kit, PN: AA-40LK, from Aseptico. Follow these steps to replace the Lens (see Figure 5):

    • a) Turn ALU-40LED power Off and unplug Lamp from power source.
    • b) Pull Lens Cover (461936) off the front of Lamp Head to expose the Fresnel Lens (461935).
    • c) Use the Torx Key (490140) to remove the three Torx Fasteners (510727). Set Fasteners aside temporarily.
    • d) Remove old Fresnel Lens and replace with new Lens, positioning new Lens, rough side out, on the outer shelf on the Front Housing (see Figure 7)
    • e) Attach Lens to Housing with the three Fasteners from Step 1c above.
    • f) Replace Lens Cover.
  2. LENS ADJUSTMENT:
    Follow these steps to adjust the position
    of the Lens so that it emits the sharpest
    beam (refer to Figures 6 & 7):

    • a) Position Lamp Head approximately 28″ (71 cm) away from a flat test surface. Turn Lamp On and observe sharpness of projected light beam (see Figure 5).

    • b) If outer edge of beam appears blurred or undefined, reposition the Lens on the next inboard shelf (see Figure 7) of the Housing (refer to Step 1 for complete instructions when detaching and reattaching the Fresnel Lens).

    • c) Repeat Step 2b, moving the Lens inward to the next shelf until the edge of the beam shows optimum sharpness and clarity. NOTE: There are a total of five different Lens adjustment shelves in the Front Housing (see Figure 7).

IMPORTANT
The LED Assembly is a non-serviceable component of the ALU-40LED Lamp. Return the entire Lamp Assembly to Aseptico if LED repairs are necessary.

  1. FUSE REPLACEMENT:|
    WARNING
    Turn the power off and unplug the unit before following the steps below.

    • Remove the Fuse Holder from the Power Inlet connector **(see Figure 8).

**

  * Replace the two fuses in Fuse holder.  

Replacement Fuses (2):
0.160A, 250V slo-blow fuse (Fuse size: 5 x 20mm)

  *  Reinstall the Fuse Holder.  

NOTE: The ALU-40LED features autosensing, global voltage compatibility. The fuses indicated are correct for 100V-240V 50/60 Hz line voltages.

  1. CLEANING:
    WARNING:
    Turn the power off and unplug the unit before following the steps below.
    CAUTION:

    • Do not use excessive amounts of fluid when cleaning.

    • Do not introduce any fluids to the inside of the Lamp Head Housing or the Power Supply Assembly.

    • Fresnel Lens:
      Remove Lens Cover and Fresnel Lens from Lamp Head. (IMPORTANT: Handle the Fresnel Lens by its edges — do not handle the active surface of the Lens.) The acrylic Fresnel lens is fragile and can be scratched. Dust is the most common contaminant and should be removed using compressed air. If additional cleaning is necessary, apply a few drops of reagent-grade isopropyl alcohol, professional lens cleaning solution, or de-ionized water with a small amount of dish soap, to a lint-free lens tissue and gently wipe Lens. Clean the Lens Cover using the same method. Reinstall Fresnel Lens and Lens Cover onto Lamp Head.

    • Metal Components:
      The metal exterior may be cleaned by wiping with a soft cloth moistened with mild detergent or disinfecting solution such as carisoprodol alcohol

    • c) Gooseneck & Electrical Cords:
      Turn Lamp power Off. Wipe down the goose neck and electrical cords with a cloth moistened with disinfecting solution.

ALU-40LED PARTS DIAGRAM

Figure 9 – Lamp   Stand Boom

PARTS LIST – Lamp Stand Boom

Item Description Part Number Qty
1 FINAL ASSY, ALU-40LED 120369 1
2 LAMP HEAD SUB ASSY 330355 11
3 SETSCREW 8-32X1/8 S/S CUP POINT 510278 1
4 GOOSENECK ALU-40LED DENTAL LAMP 461953 1
5 SET SCREW CONE PT HEX SOC M6 X 8MM BLK 510731 1
6 HEAT SHRINK 1/8 BLK 870118 1″
7 HEAT SHRINK 1/4 BLK 870120 2.5″
8 HOLE PLUG NYLON 1/2 IN BLACK 510202 19
9 M/S STNLS PHDPHL 10-24 X 5/8 THRD CUTTING 510732 1
10 END CAP, MODIFIED BOOM, ALU-40 461959 1
11 CABLE COILED 2 CONDUCTOR ALU-40LED 870319 1
12 HANDLE CLAMP LEVR, M8X1.0 FEM THRD, BLK 850076 1
13 CLAMP, BOOM ALU-40 LED 730646 1
14 BOOM, MODIFIED ALU-40LED 730645-01 1

ALU-40LED PARTS DIAGRAM

**Figure 10 – Lamp Stand & Power Supply

**

PARTS LIST – Lamp Stand & Power Supply

Item Description Part Number Qty
15 BRACKET POLE POWER SUPPLY ALU-40LED 461945 2
16 C/S BTNSOC BLK 6-32 X 1/4 510009 8
17 OVERLAY POWER SUPPLY ALU-40LED 510278 1
18 TOP HOUSING POWER SUPPLY ALU-40LED 420910 1
19 TIE WRAP 4″ PICO WHT 461943 1
20 STRAIN RELIEF 1/4 BLK FLEX 510137 1
21 HEAT SHRINK 1/2 BLK 840003 0.29′
22 DIODE GENERAL 1N4004 1A 400V AXIAL DO-41 870121 2
23 CONN .079 HSG/POL 2 PIN 880030 4
24 CONN .079 HSG/POL 3 PIN 860266 1
25 WIRE PVC #24 STRANDED WHITE 860268 1
26 WIRE PVC #24 STRANDED BLACK 870304-01 0.46′
27 TERM FEM CONN .187 X .032 22-16 870304-02 0.54′
28 NUT HEX 6-32 STNLS (FOR GRND STUD) 860053 3
29 WASHER, INT STAR #6 (FOR GRND STUD) 510293 1
30 TERM INSUL RING #6 22-16 510419 1
31 WIRE PVC #22 GRN/YEL (54) 860004 1
32 WIRE PVC #22 GRN/YEL (54) 870260 0.21′
33 CONN JACK DC POWER PCB MOUNT 860333 1
34 FUSE 5 X 20 SLO-BLO 0.160 AMP 830046 2
35 FUSE DRAWER 2 POLE 840060 1
36 POWER INLET, FUSED SWITCHED 840059 1
37 POWER SUPLY 12VDC 0.83A INPUT 85-264 VAC 840112 1
38 NUT NYLON 4-40 510554 4
39 WASHER FLAT NYLON .120IDX.250 ODX.0 510127 4
40 SPACER NYLON 1/4 RND X 7/16 L #6 510267 4
41 BASE POWER SUPPLY ALU-40LED 46194 1
42 STAND ALU 27/29 AKG BLK 730150 1
NS COLOR FILTER ALU-40LED 461974 1
NS CASE CARRYING W/BLU LOGO 410084 1
NS ADAPTER AMERICAN-TO-GERMAN GRND PLUG 840115 1
NS LINECORD REMOTE US BLACK 840107 1
NS LABEL SERIAL NUMBER ALU-40LED 420295-09 1

PARTS LIST – Lamp HeaD

i v m     Description                                Part Number Oty
E   BRACKET POLE POWER SUPPLY ALU-IDLED 461945 2

D   C/S BTNSOC BLK 632 X 1/4 510009| 8
OVERLAY POWER SUPPLY ALU-4ClED 420910| 1
HOUSING POWER SUPPLY ALU•KlED                         461943| 1
iTOP RE WRAP 4• PICO WHT 510137| 1
STRAIN RELIEF 1/4 BLK FLEX 840003| 1
SHRINK V2 BU( 870121$HEAT| OS
DIODE GENERAL 1N4004 1A 400V AXIAL DO-41 880030| 2
0                     CONN CRIMP CONTACT 30-24 AWG 860266| 4
·                         CONN .079 ICGOPOL 2 PIN 860267| 1
0                     CONN .079 ICGOPOL 3 PIN 880268| 1
0           WIRE PVC 424 STRANDED WHITE 870304-01| 0.413
0           WIRE PVC 124 STRANDED BLACK 870306-02| 0.54′
0                     TERM FEM CONN .187 X .03222-16 880053| 3
NUT HEX 8-32 STNLS (FOR GRND STUD) 510293| 1
EDB WASHER. INT STAR 06 (FOR GRND STUD)                510419| 1
0/                   TERM INSUL RING le 22-16 880004| 1
0                     WIRE PVC 122 GRNP/EL 150 670260| 0.2V
JACK DC POWER PCB MOUNT 860333| 1
$CONN FUSE 5 X 20 SLO-BLO 0.160 AMP 830046| 2
FUSE DRAWER 2 POLE 640060| 1
POWER INLFT Fl iv..Fn SWiTCHFn 8400494)| 1
POWER SUPLY I2VOC 0.63A POUT 85-264 VAC 640112| 1
NUT NYLON 4-40 510554| 4
WASHER FLAT NYLON .120IDX250 ODX.0 5101274)| 4
SPACER NYLON 114 RND X 7/16 L 46 510267| 4
CD                                       BASE POWER SUPPLY ALU-40LED 461944| i
STAND ALU 27/29 AX G BLK 730150| 1

TROUBLESHOOTING

Problem Correction
Power is ‘ON’, but lamp does not illuminate:
  • turn intensity up.
  • Replace fuses, 0.160 Amp, 5 x 20mm, 250V, slo-blow
  • Check plug and electrical source.

Light intensity appears dimmer than normal:|

  • Turn intensity up.
  • Clean Lens Cover and/or Fresnel Lens. (Note: Before cleaning, turn power to Lamp ‘Off’.)
  • Check plug and electrical source.
  • ED Assembly might be damaged
  • Return entire Lamp Assembly to Aseptico for repairs.

Fuse is blown:|

  • – Replace both fuses, 0.160 Amp, 5 x 20mm, 250V, slo-blow

SPECIFICATIONS

Lamp Height: 41″ to 69″ (Adjustable) (104.1 cm to 175.3 cm)
Boom Length: 41″ (104.1 cm)
Weight: 9.45 lbs (4.29 kg)
AC Input: 100-240V 0.160A 50-60 Hz
Auxiliary B 12-24V 0.6A
Fuses : 0.160 Amp, 250V, slo-blow (5 x 20 mm)
Consumption: 7.5 W max
Duty Cycle: Continuous
LED Life: 10,000 Hrs minimum (Lumen maintenance >70% @ 30,000 Hrs – At worst case operating temperature)

Lamphead Adjustments:

Intensity: 0% to 100% Adjustable
Aperture Size: 2-1/4″ to 4-5/8″ Diameter (5.72 cm to 11.74 cm) Adjustable @ 27.56 in. (70 cm) focal length
Beam Characteristics:
Color temperature: 6,500 Kelvin
Light Output: 1,500 ft-c @ 24″ Typ (16,145 lux @ 61 cm Typ)
Light Distribution: 7 different aperture sizes
Nominal Working Distances: 16″ (40.6 cm) w/large aperture, or 36″ (91.4 cm) w/small aperture
Light Source: LED Emitter

SYMBOL DEFINITIONS

  • Attention, consult accompanying documents
  • Type B Equipment
  • Class II Equipmen
  • Dangerous Voltage
  • Alternating curren
  • Manufacturer
  • Authorized European Representative
  • Protective Earth (Ground)
  • Temperature Limitation
  • Humidity Limitation
  • Atmospheric Pressure Limitation
  • Do Not Throw Into Trash
  • Fuse Rating

WARRANTY

Aseptico warrants this product against defects in material or workmanship for a period of two (2) years, from date of original invoice. Some handpieces are warranted for one year under the same conditions. Other handpieces and expendable components, such as air turbines and light bulbs, are covered by shorter warranty periods, or have no warranty.

Aseptico’s sole obligation under product warranty is (at its sole option and discretion) to repair or replace any defective component or product in part or whole. Aseptico shall be the sole arbiter of such action.

In the event of alleged defect under warranty, the purchaser is to notify Aseptico’s Customer Service Department promptly. Customer Service will provide instructions, usually directing that the product be returned for service. Shipment to Aseptico and the cost thereof is always the responsibility of the purchaser.

Accidental misuse, inappropriate installation, or failure to perform directed maintenance voids the warranty. Deliberately defacing, modifying, or removing the serial number voids the warranty.

Aseptico does not assume, under this warranty, any risks or liabilities arising from the clinical use of its products, whether or not such use involves coincidental utilization of products manufactured by others.

P.O. Box 1548 • Woodinville, WA 98072
8333 216th Street S.E. • Woodinville, WA 98072
425-487-3157800-426-5913
www.aseptico.com[email protected]

P/N: 420841
Rev. H
ECO 14684
03/2019