LEGEND OVERVIEW
- A: Plug
- B: S button
- C: Socket
- D: LED indication ring (LED)
READ BEFORE USE
This document contains important technical and safety information about the
Device, its safe use and installation.
⚠CAUTION! Before beginning the installation, please read carefully and
entirely this guide and any other documents accompanying the Device. Failure
to follow the installation procedures could lead to malfunction, danger to
your health and life, violation of law or refusal of legal and/or commercial
guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or
damage in case of incorrect installation or improper operation of this Device
due to failure of following the user and safety instructions in this guide.
TERMINOLOGY AND ABBREVIATIONS
Device – In this document, the term “Device” is used to refer to the Shelly
Qubino device that is a subject of this guide.
Gateway (GW) – A Z-Wave® gateway, also referred to as a Z-Wave® controller,
Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is
a device that serves as a central hub for a Z-Wave® smart home network. The
term “gateway” is used in this document.
S button – The Z-Wave® Service button, located on Z-Wave® devices and is used
for various functions such as adding (inclusion), removing (exclusion), and
resetting the device to its factory default settings. The term “S button” is
used in this document.
ABOUT SHELLY QUBINO
Shelly Qubino is a line of innovative microprocessor-managed devices, which
allow remote control of electric circuits with a smartphone, tablet, PC, or
home automation system. They work on Z-Wave® wireless communication protocol,
using a gateway. When the gateway is connected to the internet, you can
control Shelly Qubino devices remotely from anywhere. Shelly Qubino devices
can be operated in any Z-Wave® network with other Z-Wave® certified devices
from other manufacturers. All mains operated nodes within the network will act
as repeaters regardless of vendor to increase reliability of the network.
Devices are designed to work with older generations of Z-Wave® devices and
gateways.
ABOUT THE DEVICE
The Device is a smart plug/outlet with power measurement and overheating
protection, which allows remote control of electric appliances with a mobile
phone, tablet, PC, or home automation system.
ISTALLATION INSTRUCTIONS
The Device can be plugged into standard BS 1363 (Type-G) sockets and accepts standard BS 1363 (Type-G) plugs.
- CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
- CAUTION! Do not connect the Device to appliances exceeding the given max. load!
- CAUTION! Do not install the Device where it can get wet.
- CAUTION! Do not use the Device if it has been damaged!
- CAUTION! Do not attempt to service or repair the Device yourself!
- CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- CAUTION! Do not allow children to play with the device, especially with the S button. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
- CAUTION! The product is intended for indoor use only.
- CAUTION! Protect the product from dirt and moisture! Do not use the product in a damp environment!
- CAUTION! Do not plug Devices into each other!
Plug the Device into a power socket without an appliance/load connected to it. Then plug the appliance/load into the Device socket. To turn on the appliance/load, briefly press the S button. The LED will turn green if the load is 0 W, yellow if the load is between 0 W and 85% of the max. load, and red if the load is more than 85% of the max. load.
Z-WAVE® ADDING / REMOVING / FACTORY RESET
Note! All Device outputs (O, O1, O2, etc. – depending on the Device type)
will turn the load 1s on/1s off /1s on/1s off if the Device is successfully
added to/removed from a Z-Wave® network.
Note! In case of Security 2 (S2) adding (inclusion), a dialog will appear
asking you to enter the corresponding PIN Code (5 underlined digits) that are
written on the Z-Wave® DSK label on the side of the Device and on the Z-Wave®
DSK label inserted in the packaging.
IMPORTANT : The PIN Code must not be lost.
Adding the Device to a Z-Wave® network (inclusion)
SmartStart adding
SmartStart-enabled products can be added to a Z-Wave® network by scanning the Z-Wave® QR Code present on the Device with a gateway providing SmartStart inclusion. No further action is required, and the SmartStart device will be added automatically within 10 minutes of being switched on in the network vicinity.
- With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway.
- Plug the Device into a power socket.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Adding will be initiated automatically within a few seconds after plugging the Device into a power socket, and the Device will be added to a Z-Wave® network automatically.
- The blue LED will be blinking in Mode 2 during the adding process.
- The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.
Adding (inclusion) with the S button
- Plug the Device into a power socket.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
- Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode*.
- The blue LED will be blinking in Mode 2 during the adding process.
- The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.
Learn mode – a state that allows the Device to receive network information
from the gateway.
Note! In Setting mode, the Device has a timeout of 10s before entering
again into Normal mode.
Removing the Device from a Z-Wave® network (exclusion)
Note! The Device will be removed from your Z-Wave® network, but any
custom configuration parameters will not be erased.
Removing (exclusion) with the S button
- Plug the Device into a power socket.
- Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
- Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode.
- The blue LED will be blinking in Mode 2 during the removal process.
- The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave® network.
Note! In Setting mode, the Device has a timeout of 10 before entering again into Normal mode.
Factory reset
After the Factory reset, all custom parameters and stored values (kWh, associations, routings, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable.
Factory reset with the S button
Note! Factory reset with the S button is possible anytime.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
- Press the S button multiple times until the LED turns solid red.
- Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset.
- During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
- The blue LED will be blinking in Mode 1 if the Factory reset is successful.
Note! For more information about this Device refer to the Extended User Guide available at: https://kb.shelly.cloud/
LED SIGNALIZATION
LED blinking modes
Mode 1| 0,5s On/2s Off
Mode 2| 0,5s On/0,5s Off
Mode 3| 0,1s On/0,1s Off
Mode 4| (1x to 7x – 0,2s On/0,2s Off)
+ 2s Off
Mode 5| 0,2s On blue/0,2s On red
Normal mode| Colour| LED
mode
---|---|---
Excluded/Removed| Blue| Mode 1
Included/Added| Green| Mode 1
Load 0 W| Green| Solid
Load between 0 W and 85% of the max. load| Yellow| Solid
Load > 85% of the max. load| Red| Solid
Setting mode (with S button)| |
Adding/Removing (Inclusion/ Exclusion) menu selected| Blue| Solid
Adding/Removing (Inclusion/ Exclusion) menu – while pressing S button –
Adding/ Removing (Inclusion/Exclu- sion) process selected| Blue| Mode 3
Factory reset menu selected| Red| Solid
Factory reset – while pressing S button – Factory reset process selected| Red|
Mode 3
“Setting in progress” mode| |
Factory reset and reboot| Blue/Red/Green|
Adding/Removing (Inclusion/ Exclusion)| Blue| Mode 2
Checking power supply 230 V AC frequency or 24 V DC voltage| Blue/Red| Mode 5
OTA Firmware updating| Blue/Red| Mode 2
Alarm mode**| |
Overcurrent detected O| Red| Mode 4 (1x)
Overheat detected| Red| Mode 4 (2x)
Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)|
Red| Mode 4 (3x)
Overvoltage detected| Red| Mode 4 (7x)
LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
TECHNICAL SPECIFICATIONS
Power supply | 230 V ±10%, 50/60 Hz |
---|---|
Power consumption | < 0,7 W |
Power measurement (W) | Yes |
Max. switching voltage AC | 260 V |
Max. switching current AC | 13 A |
Overheating protection | Yes |
Overcurrent protection | Yes |
Overvoltage protection | Yes |
Distance | up to 40 m indoors (131 ft.) |
Z-Wave repeater: | Yes |
CPU | Z-Wave S800 |
Z-Wave frequency band | 868,4 MHz |
Maximum radio frequency power transmitted in frequency bend(s) | < 25 mW |
Size (H x W x D) | 60x60x56 ±0.5 mm / |
2.36×2.36×2.20 ±0.02 in
Weight| 74 ±1 g / 2.6 ±0.04 oz
Compatible sockets| BS 1363 (Type-G)
Compatible plugs| BS 1363 (Type-G)
Shell material| Plastic
Color| White
Ambient temperature| -20°C to 40°C / -5°F to 105°F
Humidity| 30% to 70% RH
Max. altitude| 2000 m / 6562 ft.
IMPORTANT DISCLAIMER
Z-Wave® wireless communication may not always be 100% reliable. This Device
should not be used in situations in which life and/or valuables are solely
dependent on its functioning. If the Device is not recognized by your gateway
or appears incorrectly, you may need to change the Device type manually and
ensure that your gateway supports Z-Wave Plus® multi-channel devices.
CLEANING
- CAUTION! Before cleaning the Device power off the connected appliance by pressing the S button, unplug it, and then unplug the Device itself. Never clean the Device if it is connected to the mains!
- CAUTION! Use a wet soft cloth to clean the Device.
- CAUTION! Do not use aggressive detergents!
- CAUTION! Do not immerse the Device or wash it under running water!
DISPOSAL AND RECYCLING
This refers to the waste of electrical and electronic equipment. It is
applicable in the EU, UK, US, and other countries to collect waste separately.
This symbol on the product or in the accompanying literature indicates that
the product should not be disposed of in the daily waste. Wave Plug UK must be
recycled to avoid possible damage to the environment or human health from
uncontrolled waste disposal and to promote the reuse of materials and
resources. It is your responsibility to dispose of the device separately from
general household waste when it is already unusable.
ORDERING CODE: QNPL-001X12UK
DECLARATION OF CONFORMITY
Hereby, Shelly Europe Ltd. (former Allterco Robotics EOOD) declares that the radio equipment type Wave Plug UK complies with Directive 2014/53/ EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: https://shelly.link/WavePlugUK-DoC
MANUFACTURER:
Shelly Europe Ltd.
Address: 103 Cherni Vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support: https://support.shelly.cloud/
Web : https://www.shelly.com
Changes in the contact data are published by the Manufacturer at the official
website: https://www.shelly.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>