CAMDEN CX-ED2071 Electric Strike Instruction Manual

June 17, 2024
Camden

CAMDEN CX-ED2071 Electric Strike

Specifications

  • Voltage: 8/16V AC/DC
  • Current Draw: 305mA@8V DC, 190mA@8V AC, 625mA@16V DC, 460mA@16V AC
  • Static Strength: 1,000 Lbs.
  • Dynamic Strength: 50 Ft-Lbs.
  • Endurance: 700,000 Cycles
  • Mode: Field Selectable Fail Safe/Fail Secure
  • Mech. Adjustment: Strike Body/Faceplate
  • Operation: AC-Buzz DC-Silent
  • Duty: Intermittent
  • Dimensions (Body): 3 3/8 H x 1 7/8 W x 1 7/32 D (86mm x 47mm x 31mm)

Product Usage Instructions

Installation

  1. Prepare the door jamb as per the appropriate drawing.
  2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
  3. Spacers are used to assure flush final assembly of faceplate into jamb. Add one or more spacers between jamb and mounting bracket when face plate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting bracket & the lip bracket. Make sure the clearance hole in the spacer aligns with the hole in the mounting bracket.
  4. Connect wires coming from the low voltage side of the transformer to wires (black) from the strike.
  5. Install electric strike jamb by attaching with #10-32 screws and lockwashers.
  6. Secure M5x12 screws holding mounting brackets to jamb.

Connections
A varistor is provided to protect/prevent the strike from spikes. Connect the varistor between input wires.

Note: The door strikes are to be powered via a class 2 power limit output from a control panel or power supply that is UL listed to UL Burglar Alarm/Access control standards.

Operation

  1. Ensure that the strike is properly seated.
  2. Tighten the screw.

FAQ

Q: What voltage does the CX-ED2071 Electric Strike support?
A: The CX-ED2071 Electric Strike supports 8/16V AC/DC voltage.

Q: What is the static strength of the strike?
A: The static strength of the strike is 1,000 Lbs.

Q: How many cycles can the strike endure?
A: The strike can endure 700,000 cycles.

This Package Includes

  • 1- ESP1B, ESP3B and ESP4B faceplates
  • 4- Wire nuts
  • 5- M5 x 12mm screws
  • 2- #10 x 1 1/4” wood screws
  • 2- #10-32 x 1/2” screws
  • 2- Mounting brackets
  • 2- Spacers
  • 1- Varistor

Description

Camden CX-ED2071 low profile Grade 2 ANSI strike for cylindrical locksets offers the very best strike quality and performance, with three stainless steel faceplates provided. The ‘Universal’ strike design delivers unparalleled application flexibility, fail safe/fail secure operation and mechanical adjustment of the strike body.

Specifications

Voltage 8/16V AC/DC
Current Draw 305mA@8V DC 190mA@8V AC

625mA@16V DC 460mA@16V AC

Static Strength| 1,000 Lbs.
Dynamic Strength| 50 Ft-Lbs.
Endurance| 700,000 Cycles
Mode| Field Selectable

Fail Safe/Fail Secure

Mech. Adjustment| Strike Body/Faceplate
Operation| AC-Buzz DC-Silent
Duty| Intermittent
Dimensions| 3 3/8” H x 1 7/8” W x 1 7/32” D
(Body)| (86mm x 47mm x 31mm)

Dimensions

CAMDEN-CX-ED2071-Electric-Strike-1

Installation

  1. Prepare the door jamb as per the appropriate drawing.
  2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
  3. Spacers are used to assure flush final assembly of faceplate into jamb. Add one of more spacers between jamb and mounting bracket when face plate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting bracket & the lip bracket. Make sure clearance hole in spacer aligns with hole in mounting bracket.CAMDEN-CX-ED2071-Electric-Strike-2
  4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
  5. Install electric strike jamb by attaching with # 10-32 screws and lockwashers.
  6. Secure M5x12 screws holding mounting brackets to jamb.

CAMDEN-CX-ED2071-Electric-Strike-3

Note: The products are intended to be installed in accordance with the installation wiring diagram, mechanical assembly drawings provided with each product, the local authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70. When installed in fail secure mode, the local authority shall be consulted with regard to the use of possible panic hardware to allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and in such a location so as to not impair the operation of an emergency exit device or panic hardware mounted on the door.

Connections

POWER

8/16V AC/DC

  • Red: Power in
  • Red: Power in

A varistor is provided to protect/prevent strike from spikes.
Connect varistor between input wires.

Note: The door strikes are to be powered via a class 2 power limit output from a control panel or power supply that is UL listed to UL Burglar Alarm/Access control standards.

Operation

How to modify fail-safe to fail-secure or vice versa.

  1. Loosen the screw as per the product diagram below.
  2. Rotate the set plate 180° and slide the plate until it is properly seated.
  3. Tighten the screw.

Faceplates

CAMDEN-CX-ED2071-Electric-Strike-7

5502 Timberlea Blvd.,Mississauga, ON Canada
L4W 2T7

www.camdencontrols.com
Toll Free: 1.877.226.3369
File: CX-ED2071 Designer
Installation Instructions.indd R2
Revision: 01/06/2018
Part No.: 40-82B210