CAMDEN CM-SRFM2 Wireless 2 Channel Receiver Installation Guide
- June 10, 2024
- Camden
Table of Contents
CAMDEN CM-SRFM2 Wireless 2 Channel Receiver
Product Information
CM-SRFM2 Kit Wireless 2 Channel Receiver with two transmitters
Specifications
- FCC ID: U5Z-CONNECT4CC
- Input Power: 12V or 24V AC/DC
- Standby Current: 18mA (Input VDC12V)
- Operating Current: 80mA (Input VDC12V)
- Working Humidity: 0-95%
- Working Temperature
- Lock Relay Memory Encryption: 30 codes High security rolling code. 19 trillion combinations
- Number of Relays: 2 relays; 1ST relay momentary, 2ND momentary or latching/bi-stable
- Frequency: 868.35 MHz
- IP Rating: 65 with grommet
- Receiver Dimensions: 7-3/8 W x 3-1/4 H x 1-5/8 D (187mm x 82mm x 42mm)
- Transmitter Battery: CR3032 3 volt
- Transmitter Dimensions: 2 W x 3/16 H x 1 D (55mm x 30mm x 10mm)
Description
The CM-SRFM2 is a wireless transmitter kit that includes two, 2 button transmitters and one 2 channel receiver. This kit will control up to two doors from one device. Ideal for front desk/reception applications or hard-to-wire locations. Designed to work with magnetic locks, electric strikes, keypads, gate operators and door operators. Kits include channel receiver and transmitter.
- Receiver can be mounted inside or outside. IP65 rated
- Rolling code encryption
- Field configurable latching/bi-stable mode keeps doors unlocked until button is pressed again
- Receiver can be controlled by up to 30 transmitters
- Receiver relay mode is either momentary or bi-stable for 2nd relay.
Dimensions
- Length: 5 inches (127mm)
- Width: 3-1/4 inches (82mm)
- Height: 7-3/8 inches (187mm)
Installation:
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the cables through the bottom of the receiver. Connect the power cables to the 12/24V terminals marked on the PCB board as indicated. (Left terminal is positive) Seal and cover the receiver front cover to the base using the screws supplied.
- Antenna Connection
- Jumper 12/24V
- Channel 1 Operation LED
- Channel 2 Operation LED
- Programming Push Button
- Jumper Reset
- Microswitch Impulse/Bi-Stable
- Power Supply
- Relay 1 Output
- Relay 2 Output
- Memory Card Connection
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the cables through the bottom of the receiver. Connect the power cables to the 12/24V terminals marked on the PCB board as indicated. (Left terminal is positive) Seal and cover the receiver front cover to the base using the screws supplied.
Operation
The two red LED lights flash every 5 seconds to confirm power is applied to
the receiver. Upon receiving a code, the receiver checks whether it is in its
memory, activating the corresponding relay.
The relay activation mode is selected in either impulse or ON/OFF using the
Imp/Bis jumper. Only relay 2 can have its mode changed by this jumper from
momentary to bi-stable.
Changing the mode for relay 1 can only be accomplished at the factory.
Programming
Manual programming
Press the receiver programming button for 1 sec. and an acoustic signal will
be heard. The receiver will enter programming (see table below). If the
receiver programming button is held pressed down, the receiver will
sequentially go from one configuration to the next. Once the programming
configuration for the transmitter to be registered has been chosen, send the
code to be programmed by pressing the respective transmitter button (1 or 2).
Every time a transmitter is programmed, the receiver will issue an acoustic
signal for 0.5 seconds for confirmation. After 10 seconds without programming
or pressing the first two transmitter buttons, the receiver will automatically
exit programming mode while beeping one second twice. If upon programming a
transmitter the receiver memory is full, the receiver will emit 7 beeps of 0.5
seconds and exit programming.
The receiver is always configured in multi-channel.
Configuration of Transmitter Programming in the Receiver:
- LED R1: The 1st relay is activated by channel 1
- LED R2: The 2nd relay is activated by channel 2
Special Programming
Press the transmitter channel to activate the relay 1 on the receiver | ON | OFF |
---|---|---|
Press the transmitter channel to activate the relay 2 on the receiver | OFF | ON |
Press the transmitter channel to activate the two relays at once * | ON | ON |
To activate relay 1 on the receiver, press the transmitter channel.
If working in latching/bi-stable ON/OFF activation mode, relay 1 will act as impulse and relay 2 as ON/OFF. Therefore, on the first press relay 1 will close and open the contact and relay 2 will only close. On the second, relay 1 will close and open the contact and relay 2 will open.
NOTE : Each transmitter can be configured independently on the receiver.
Total Reset
In programming mode, press the programming button down and simultaneously
short the “MR” jumper for 3 seconds. The receiver will issue 10 short acoustic
warning signals followed by others at a faster pace to indicate that the
operation has been successful. The receiver is now in programming mode. After
10 seconds without programming or quickly pressing the programming button, the
receiver will exit programming mode, issuing two, one second beep signals.
THIS PACKAGE INCLUDES
- (1) CM-SRX2 Receiver
- (1) User Manual
- (2) Transmitters CV-WTX2
- (2) Wall Plugs (used for mounting)
- (2) Selft Tapping Screws (used for mounting)
- (1) Grommet
TRANSMITTER
BATTERY REPLACEMENT / REMPLACEMENT DE LA BATTERIE
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
Opening New Doors to Innovation, Quality, and Support!
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
File: 40-82B317 CM-SRFM2
Instructions Manual.indd
Rev: 0 | Date: November 2, 2022
Part No.: 40-82B317
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>