CAMDEN CM-331 Battery Operated Active Infra-Red Hands-Free Switches Instruction Manual
- June 10, 2024
- Camden
Table of Contents
CAMDEN CM-331 Battery Operated Active Infra-Red Hands-Free Switches
Product Information
Door Activation Devices CM-336
The CM-336 is a battery-operated active infra-red hands-free switch that provides barrier-free access and egress to buildings and washroom facilities. It is American Disability Act (ADA) compliant and has a rugged construction that makes it ideal for use on low-energy automatic doors, drive-up windows, and interior and exterior doors in virtually any commercial, institutional, or industrial facility. The switch is available in three standard faceplate widths and can be ordered with different symbols and words.
Applications
The CM-336 is suitable for use in commercial (office, retail), institutional (school, hospital, or clinic), or industrial (manufacturing) facilities. It can be mounted in door jambs, single or double gang electrical boxes, and 4 x 4 boxes. The sealing gasket is recommended for outdoor or wet locations. If using Automatic doors install them in accordance with ANSI A156.10 / A156.19.
Installation Instructions
Mounting: The CM-336 may be mounted in a single gang electrical box, double gang electrical box, or 4×4 box. Follow the steps below for installing the switch in a single gang electrical box:
- If using an in-wall box, ensure the box is plumb and square and flush with the wall surface. If using a surface box, ensure it is secure & plumb.
- Using the dip switch located on the end of the unit, set the operating mode.
- Attach the unit to the enclosure using the two #6-32 screws provided.
- Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
- Do not over-tighten!
Wiring: The CM-336 is powered by 2 AA batteries (supplied). The battery holder has been pre-installed. Insert the batteries into the battery holder, ensuring that the polarity of the batteries is correct.
Pairing the CM-336
The CM-336 battery-operated wireless SureWaveTM switch utilizes Lazerpoint RF technology and is for use with Camden CMRX90 V2, CM-RX91, or CM-RX92 Lazerpoint receivers. If you wait longer than the 10-second period, the receiver will time out of Pairing Mode and revert back to standby. The LED will then flash to indicate the number of transmitters learned into the receiver. Refer to Diagrams 1, 2, and 3 in the user manual for further details on installation and dip switch settings.
GENERAL DESCRIPTION
Sure-Wave™ Hands-Free switches are active infra-red devices utilizing micro burst sensor technology, designed for use in ADA compliant automatic door control applications. These switches eliminate the spread of germs by avoiding physical contact and offer building occupants greater convenience when moving through the premises. Sure-Wave™ switches are available with either stainless steel or impact-resistant polycarbonate faceplates, in narrow (jamb), single gang, or double gang configurations. All models are ROHS-compliant with lead- free construction.
APPLICATION
- Sure-Wave™ battery powered hands-free switches are American Disability Act (ADA) compliant, and provide barrier free access and egress to buildings and washroom facilities.
- Their rugged construction makes them ideal for use on low-energy automatic doors, drive-up windows, and interior and exterior doors in virtually any commercial (office, retail), institutional (school, hospital or clinic), or industrial
(manufacturing) facility.
Three standard face plate widths are available:
- CM-336: 2 ¾” x 4 ½” polycarbonate or stainless steel, fits on single gang electrical boxes.
- CM-336/N : 1 ¾” x 4 ½” polycarbonate or stainless steel.
- CM-336/W: 4 ½” x 4 ½” polycarbonate or stainless steel, fits on single gang, double gang or 4 x 4 electrical boxes.
- All faceplates may be ordered up with a plain face, with the waving hand symbol (/40), with the waving hand symbol and words: WAVE TO OPEN (/41) or with the waving hand, and wheelchair icons plus words: WAVE TO OPEN (/42).
INSTALLATION
Mounting
- Sure-Wave™ may be mounted in door jambs, single or double gang electrical boxes, and 4 x 4 boxes.
- NOTE: The sealing gasket (included) is recommended for outdoor or wet locations. If using with Automatic doors install in accordance with ANSI A156.10 / A156.19. Select from one of the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-336
- 1a – If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. (See Diagram 1)
- 1b – If using a surface box, ensure it is secure & plumb.
- Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)
- Attach the unit to the enclosure using the two #6-32 screws provided.
- Attach the faceplate to the unit using the two black 32 x 3/8 machine screws or tamperproof screws.
Do not overtighten
2- GANG (or 4×4) ELECTRICAL BOX: CM-336W
-
* **1a –** If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. (See Diagram 1)
- 1b – If using a surface box, ensure it is secure & plumb.
- 1c – If using a 4 x 4 box, ensure the box is plumb and square, and flush with the wall surface, then attach the metal adaptor plate (included in the CM-336W package) to the box using appropriate fasteners.
- Attach the unit to the enclosure using the two #6-32 screws provided.
- Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten
Pairing the CM-336
- The CM-336 battery operated wireless SureWave™ switch utilizes our Lazerpoint RF technology and is for use with Camden CM-RX90 V2, CM-RX91 or CM-RX92 Lazerpoint receivers.
- To pair the CM-336 transmitter to a receiver, press the PB1 (or PB2 on the CM-RX92) button on the receiver using a small blunt object such as a small blade screwdriver or similar. Within 10 seconds, wave your hand in front of the CM-336 to activate it. The Green LED Array on the receiver will flash once to confirm enrollment. Repeat with any additional CM-336 wireless Sure-wave™ switches. Activating the paired CM-336 again will signal the receiver that you are finished programming and LED’s 1 & 2 will flash, in an alternating sequence. Activating the CM-336 a third time will activate the receiver’s relay and corresponding LED, and also the device connected to the relay contacts.
- If you wait longer than the 10 second period, the receiver will time out of Pairing Mode and revert back to standby. The LED will then flash to indicate the number of transmitters learned into the receiver.
Wiring
- CAUTION: Do not apply power to the unit until all wiring is complete, and dip-switches have been set.
- The CM-336 is powered from 2 AA batteries (supplied). The battery holder has been pre-installed. Insert the batteries into the battery holder. Please be careful that the polarity of the batteries is correct.
APPLICATIONS & SET-UP APPLICATIONS
- See Diagram 3 for the location of the Dip switches.
- DIP Switch Settings
- DIP Switch 1
CM-336 | Description |
---|---|
1 | LED Enable |
2 | Audio Enable |
3 | Not Used |
4 | Not Used |
Switch 1 – LED On/LED Off
- This switch disables the LED, should this feature be desired. Factory setting is OFF. This feature will decrease the battery life if set to ON.
Switch 2 – Audio Enable
- Set this switch ON to enable an audible beep every time the switch is activated. Factory default is OFF. Enabling this feature will use additional power and decrease the life of the battery.
Battery Strength Meter
- To check the battery strength, place an object in front of the Surewave™ switch for approximately 5 seconds. The Surewave™ switch will beep up to 5 times indicating the battery charge level. 5 beeps being fully charged. 1-3 beeps indicates you should change the batteries.
Adjustments
- Once the Dip switches have been set, and the unit is installed in the frame or enclosure, apply power to the unit and observe operation.
- Set both potentiometers to minimum setting initially
- (fully counter-clockwise).
- Adjust the range potentiometer by turning the pot in a clockwise manner, and passing your hand in front of the unit. Rotate the pot until the desired range is obtained.
- See Diagram 3 for locations.
SYSTEM INSPECTION INSTRUCTIONS
- After the Installation and operational check of the system:
- Place warning label on the door (as per ANSI A156.10 or A156.19 guidelines). This will advise the person entering the swing side zone that the door will move.
- Instruct the owner on door system operation and how to test it. This should be checked on a daily basis.
- Instruct the owner on what to do if the door or any of its components become damaged.
- Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement.
TECHNICAL DATA
No. of IR Sensors | (1) |
---|---|
Batteries (Supplied) | (2) ‘AA’ Alkaline (Supplied) |
Estimated Battery Life | 2 Years (Based on 100 Operations/Day) |
Standard Operating Range | 1”- 12” (25.4mm – 304mm) |
Factory Set to 6” (152mm)
Operating Mode| Momentary
Inputs| Request to Exit (to trigger the relay remotely or from the other
side of the door)
Wireless Output| Built-in 915Mhz. Spread Spectrum Wireless Transmitter
- Opening New Doors to Innovation, Quality, and Support!
- Call: 1.877.226.3369 / 905.366.3377 Visit:www.camdencontrols.com
- File: CM-336_Manual.indd Revised: 06/27/22
Part No: 40-82B311
Documents / Resources
|
CAMDEN CM-331 Battery Operated Active Infra-Red Hands-Free
Switches
[pdf] Instruction Manual
CM-331 Battery Operated Active Infra-Red Hands-Free Switches, CM-331, Battery
Operated Active Infra-Red Hands-Free Switches, Operated Active Infra-Red
Hands-Free Switches, Active Infra-Red Hands-Free Switches, Infra-Red Hands-
Free Switches, Hands-Free Switches, Switches
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>