CAMDEN CX-ED1079L Universal Electric Strike Instruction Manual

June 17, 2024
Camden

CAMDEN CX-ED1079L Universal Electric Strike

Product Information

CX-ED1079L/DL ‘Universal’ Electric Strike

Specifications

  • Voltage: 12/24V AC/DC
  • Current Draw: 260mA@12V DC, 150mA@24V DC
  • Static Strength: 1,500 Lbs.
  • Dynamic Strength: 70 Ft-Lbs.
  • Endurance Mode: 1,000,000 Cycles (Factory Tested), 250,000Cycles (UL Verified)
  • Mech. Adjustment: Field Selectable Fail Safe/Fail Secure
  • Operation: AC-Buzz, DC-Silent
  • Duty: Continuous
  • Latch Bolt Monitor: SPDT, 100mA @ 24V DC
  • Dimensions (Body):
    • CX-ED1079L: 3 3/8 H x 1 3/4 W x 1 7/32 D (86mm x 44mm x31mm)
    • CX-ED1079DL: 3 3/8 H x 1 3/4 W x 1 3/8 D (86mm x 44mm x35mm)
  • UL 294 Performance Levels:
    • Line Security = Level I
    • Attack Level = Level I
    • Endurance Level = Level IV
    • Standby Power = Level I

Installation Instructions

  1. Prepare the door jamb as per the appropriate drawing.
  2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
  3. Spacers are used to assure flush final assembly of faceplate into jamb. Add one or more spacers between jamb and mounting bracket when faceplate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting bracket & the lip bracket. Make sure the clearance hole in the spacer aligns with the hole in mounting bracket.
  4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
  5. Install electric strike jamb by attaching with #10-32 screws and lockwashers.
  6. Tighten secure M5x12 screws holding mounting brackets to jamb.

Connections

  • POWER 12V AC/DC:
    • Red/Black: +12V
    • Blue/Green: Ground
  • 24V AC/DC:
    • Red: +24V
    • Black/Blue: – Ground

Frequently Asked Questions (FAQ)

Q: What is the voltage range for this electric strike?
A:
The voltage range for this electric strike is 12/24V AC/DC.

Q: What is the static strength of this electricstrike?
A:
The static strength of this electric strike is 1,500 Lbs.

Q: How many cycles has this electric strike been tested for?
A:
This electric strike has been factory tested for 1,000,000 cycles and UL verified for 250,000 cycles.

Q: Can this electric strike be used in both fail-safe and fail-secure modes?
A:
Yes, this electric strike has field selectable voltage for both fail-safe and fail-secure operation.

CX-ED1079L/DL
‘Universal’ Electric Strike
Installation Instructions

This Package Includes

  • 1- 4 PIN power connector
  • 1- 3 PIN door status connector
  • 1- ESP1B, ESP3B and ESP4B faceplates
  • 4- Wire nuts
  • 5- M5 x 12 mm screws
  • 2- #10 x 1 1/4” wood screws
  • 2- #10-32 x 1/2” screws
  • 2- Mounting brackets
  • 2- Spacers
  • 1- Varistor

Description

Camden CX-ED1079L/DL Grade 1 ANSI strikes for cylindrical locksets offer the very best strike quality and performance, with three stainless steel faceplates provided. The ‘Universal’ strike design delivers unparalleled application flexibility, with field selectable voltage, fail safe/fail secure operation and mechanical adjustment of the strike body.

Specifications

Voltage 12/24V AC/DC
Current Draw 260mA@12V DC

150mA@24V DC

Static Strength| 1,500 Lbs.
Dynamic Strength| 70 Ft-Lbs.
Endurance| 1,000,000 Cycles (Factory Tested) 250,000 Cycles (UL Verified)
Mode| Field Selectable

Fail Safe/Fail Secure

Mech. Adjustment| Strike Body/Faceplate
Operation| AC-Buzz, DC-Silent
Duty| Continuous
Latch Bolt Monitor| SPDT, 100mA @ 24V DC
Dimensions (Body)| CX- ED1079L:

3 3/8” H x 1 3/4” W x 1 7/32” D

(86mm x 44mm x 31mm)

CX- ED1079DL:

3 3/8” H x 1 3/4” W x 1 3/8” D

(86mm x 44mm x 35mm)

UL 294 Performance Levels

  • Line Security = Level I
  • Attack Level = Level I
  • Endurance Level = Level IV
  • Standby Power = Level I

Dimensions

CAMDEN-CX-ED1079L-Universal-Electric-Strike-1

Installation

  1. Prepare the door jamb as per the appropriate drawing.
  2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
  3. Spacers are used to assure flush final assembly of faceplate into jamb. Add one or more spacers between jamb and mounting bracket when face plate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting bracket & the lip bracket. Make sure the clearance hole in the spacer aligns with the hole in mounting bracket.
  4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
  5. Install electric strike jamb by attaching with # 10-32 screws and lockwashers.
  6. Tighten secure M5x12 screws holding mounting brackets to jamb.

CAMDEN-CX-ED1079L-Universal-Electric-Strike-4

Note: The products are intended to be installed in accordance with the installation wiring diagram, mechanical assembly drawings provided with each product, the local authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70.

When installed in fail secure mode, the local authority shall be consulted with regard to the use of possible panic hardware to allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and in such a location so as to not impair the operation of an emergency exit device or panic hardware mounted on the door.

Connections

POWER

A varistor is provided to protect/prevent strike from spikes.
Connect varistor between input wires.

Note: For UL 294 / UL 1034 compliance the door strikes are to be powered via a UL 294/ UL 603 class 2 power limited output from a control panel and or power supply.
Furthermore, when powered by AC/DC the units shall use a UL regulated UL 294/ UL 603 power limited class 2 output rated 12/24V with AC on indicator.

Operation

How to modify fail-safe to fail-secure or vice versa.

  1. Loosen the screw as per the product diagram below.
  2. Rotate the set plate 180° and slide the plate until it is properly seated.
  3. Tighten the screw.

Faceplates

CAMDEN-CX-ED1079L-Universal-Electric-Strike-8

5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7

www.camdencontrols.com
Toll Free: 1.877.226.3369

File: CX-ED1079L/DL Designer
Installation Instructions.indd R4
Revision: 04/11/2018
Part No.: 40-82B192