CREE CR6-625L-27K-12-GU24-FD CR6 Series LED Recessed Light Modules Instruction Manual
- June 17, 2024
- CREE
Table of Contents
CR6 Series
CR6-625L-27K-12-GU24-FD
CR6-625L-27K-12-E26-FD
INSTALLATION INSTRUCTIONS
IMPORTANT SAFEGUARDS
WARNING – Risk of Electric Shock. Disconnect power at fuse or circuit
breaker before installing or servicing.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
-
It may be necessary to remove a socket mounting plate for adequate clearance.
-
Each lampholder shall be installed only in its intended manner and orientation.
-
Not all existing recessed housings that meet these requirements will be compatible with the CR6. To ensure compatibility, a test installation should be conducted.
-
Suitable for Wet Locations.
-
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
-
LED Retrofit Kit installation requires knowledge of luminaires electrical systems.
If not qualified, do not attempt installation. Contact a qualified electrician. -
Min. temperature rating of 0°F or -18 °C.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
RECESSED HOUSING COMPATIBILITY
- The CR6 LED Downlight is designed to install in standard 6” recessed downlight housings.
- For a list of compatible housings, visit www.cree.com/lighting.
- Compatible with most dimmers when used with multiple CR6 Downlight fixtures. Consult www.cree.com/lighting for a compatibility chart.
- Compatibility of housings not on this list may be determined by measurement of the housing as detailed in the drawing above. (Figure 1).
TO I NSTALL:
STEP 1:
Remove CR6 fixture from the packaging and rotate the “Flip Clips” clockwise
until the clips are oriented directly away from the fixture. This position is
the “installation ready” position. See Figure 2.
STEP 2:
Make sure the POWER IS TURNED OFF at the source to the recessed housing(s)
that you are installing the fixture(s) in.
STEP 3: Once power has been turned off, remove existing trim and bulb,
revealing the existing socket.
STEP 4: Locate the socket in your existing recessed housing and remove any
screws that prevent the socket bracket from being removed. See Figure 3.
STEP 5: Pull socket assembly, including the bracket, as low as possible given
the existing wire length available. (May require socket plate removal) Remove
any excess bracketry from socket. Care should be taken not to damage wiring
during this process. See Figure 4.
WARNING: To prevent wiring damage or abrasion, DO NOT expose wiring to
edges of sheet metal or other sharp objects
STEP 6: Once you have removed the excess bracketry from the socket, you are
now ready to install the CR6 fixture. See Figur STEP 7:
If the existing socket is a GU24-style socket, or if you are converting the
existing socket from an edison-style socket to a GU24-style socket, proceed to
Step A under “GU24 Installation” below. (GU24 adapter only included with
CR6-GU24 models.)
STEP 8:
Attach CR6 Downlight to recessed housing socket. Screw CR6 Downlight into the
socket by turning clockwise. See Figure 6.
STEP 9: Slide CR6 Downlight with clips, in fullydeployed position, up
into the recessed housing firmly until trim ring is flush with ceiling. See
Figure 7.
GU24 INSTALLATION (WHERE REQUIRED)
GU-24
Socket Whip (Provided with GU24 units only to convert existing edison socket
fixtures to GU24)
STEP A: Remove GU-24 connector cable from box.
STEP B: Follow steps 1-6 of “INSTALLATION INSTRUCTIONS” shown on page 1.
STEP C: If the recessed housing is providedwith a GU24-style socket, Skip to
Step G.
STEP C1: To assemble included GU24 whip(shown above) cut wires on back side of
socket. No stripping is required from remaining leads.
STEP D: Insert the input wires into the Insulation Displacement Connectors
provided on the GU-24 Socket whip and clamp down on the metal u-connector
untiflush with the top of the plastic insulator.
STEP E: Close plastic hinged cover and snap lock.
STEP F: Place “Original Luminaire Modification Marking” label inside recessed
housing adjacent to existing relamp label.
STEP G: Attach GU24 socket to the CR6 by inserting pins into the socket and
twisting socket clockwise until locked.
STEP H: Continue to Step 9 shown above.
REMOVAL OF CR6 DOWNLIGHT
NOTE: Make sure power to fixture is disconnected before attempting to
remove CR6 Downlight module from fixture. STEP 1: To remove CR6 Downlight
module, grip firmly on the trim ring and rotate 1/4 turn counterclockwise to
unlock clips from recessed can.
STEP 2: Continue to turn counterclockwise as you pull downward on the CR6
Downlight. This will disengage the clips allowing the CR6 to pull free.
STEP 3: Detach CR6 Downlight from recessed housing socket.
NOTE: This device is not intended for use with emergency exit fixtures or
emergency exit lights.
In compliance with CA Prop 65, Cree provides the following statement due to
the customary electronics components used in this product. WARNING: This
product contains a chemical known to the state of California to cause cancer,
birth defects or other reproductive harm.
Limited Warranty: Cree warrants to the original purchaser (the “Buyer”) of the
Cree® CR Series downlight purchased (the “Product”), that the Product will be
free from material defects in workmanship and materials under normal use and
service and conform to Cree’s written specifications. This limited warranty
extends for a period of five (5) years from the date of original purchase of
the Product (the “Warranty Period”). There is NO WARRANTY in cases of damage
to the Product in transit or damage caused by your negligence; abuse; abnormal
usage; misuse; accidents; damage due to environmental, corrosive or natural
elements; improper power supply; failure to follow Cree’s instructions or
applicable electrical codes; improper installation, storage or maintenance;
damage due to acts of God; fire; vandalism; civil disturbances; power surges;
alteration; mishandling; and incorrectly or improperly performing maintenance
or repair by someone other than Cree or its authorized service provider.
Remedy: If the Product proves defective during the Warranty Period and the
Product return procedures set forth below are followed, Cree will in its sole
discretion, as its sole and exclusive obligation under this warranty, refund
you the purchase price of the Product, repair the Product or replace the
Product without charge, F.O.B. Cree’s designated facility. Proof of original
purchase date (e.g., sales receipt or original invoice) is required for this
limited warranty to apply. CREE SHALL NOT BE LIABLE TO BUYER, OR TO ANYONE
CLAIMING UNDER BUYER, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, INCLUDING, BUT
NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT
OR WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH
RESPECT TO THE PRODUCTS OR CREE’S ACTS OR OMISSIONS OR OTHERWISE. This limited
warranty does not cover the cost of field labor or expenses related to the
repair or replacement of the Product. Cree reserves the right to utilize new,
reconditioned, refurbished, repaired or remanufactured products or parts in
the warranty repair or replacement process. Such products and parts will be
comparable in function and performance to an original product or part, as
determined by Cree in its sole discretion, and warranted for the remainder of
the original warranty period. This limited warranty applies only to a Product
purchased within the United States (including the lower 48 states, the
District of Columbia, Hawaii, Alaska, Puerto Rico and the U.S. Virgin Islands,
but excluding APO/FPO addresses that are outside of those named jurisdictions)
(collectively, the “Territory”). Replacement and repaired Product or parts
will only be shipped to addresses within the Territory, and refunds will only
be credited to accounts located within the Territory. Making a Warranty Claim:
Notice of any warranty claim should be sent to Cree at the following address:
9201 Washington Avenue, Racine, WI 53406 or you may call Cree at
800-236-6800 to receive a RGA# and
instructions for return of the Product, freight prepaid. Further Limitations:
TO THE EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY AND REMEDIES SET FORTH
ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES
(INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE). IF WE CANNOT LAWFULLY DISCLAIM STATUTORY OR
IMPLIED WARRANTIES, THEN TO THE EXTENT PERMITTED BY LAW, ALL SUCH WARRANTIES
WILL BE LIMITED IN DURATION TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY
AND TO REFUND, REPAIR OR REPLACEMENT SERVICE AS DETERMINED BY CREE IN ITS SOLE
DISCRETION. Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you. IN NO EVENT
SHALL CREE BE LIABLE FOR INCIDENTAL, COMPENSATORY, CONSEQUENTIAL, INDIRECT,
SPECIAL OR OTHER DAMAGES. CREE’S AGGREGATE LIABILITY WITH RESPECT TO A
DEFECTIVE PRODUCT SHALL BE LIMITED TO THE MONIES PAID TO CREE FOR THAT
DEFECTIVE PRODUCT. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This limited warranty gives Buyer specific legal rights, and
Buyer may also have other rights which vary from state to state. Effective
Date: January 1, 2013
LPN000158_E
www.cree.com/lighting
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>