dacor HDPR30S Heritage Dual Fuel Pro Range User Guide

June 17, 2024
dacor

dacor HDPR30S Heritage Dual Fuel Pro Range

dacor HDPR30S Heritage Dual Fuel Pro Range

Important Information

  •  Observe all governing codes and ordinances during planning and installation. Contact your local building department fordetails.t
  • The range must be installed as specified in its installation instructions.

Critical Depth/Height Dimensions

HDPRS model shown; common dimensions given;
unique HDPRS/HDERS dimensions indicated

Critical Depth/Height Dimensions

Critical Depth/Height Dimensions

ELECTRICAL REQUIREMENTS

Model| Required Circuit| Total Connected Load
HDPR30S, HDER30S| 240 Vac, 60 Hz, 30 Amp.| 5.75 kW (24.0 Amp.)
HDPR36S, HDER36S
HDPR48S, HDER48S| 240 Vac
, 60 Hz, 50 Amp.| 10.1kW (41.9Amp.)
*4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are for reference only; see the range’s data label (back of range) for exact specifications.

The wiring must be long enough that the range can be pulled out  for service, without being disconnected. Wiring to the range must:

  • meet NEMA standards and the requirements in the above table

  • include a strain relief

  • be terminated by tinned leads, closed-loop terminals, ore penanced spade lugs with upturned ends

  • connect to a junction box or receptacle installed by a licensed electrician.
    The range maybe connected via one of these two methods:

  • 4-wire conduit connected to a 4-wire junction box

  • 3-wire conduit (where local code permits, not for use with new branch circuit installations) connected to a 3-wire junction box. Using a power cord:

  • A 4-wire power cord with a NEMA14-50P plug connected to a NEMA 14-50R receptacle:
    Using A Power Cord

  • A 3-wire power cord (where permitted) with a NEMA10-50P plug connected to a NEMA 10-50R receptacle.
    Using A Power Cord

  • The power-cord plug must be UL listed type SRD or SRDT.

  • Range models DYRP36D-C-S and DYRP48D-C-S come with a factory installed 4-wire appliance cord with NEMA14-50P plug. For freestanding ranges installed in Canada, a factory installed 4-wire appliance cord with NEMA 14-50P plug is required, without modification.

**MINIMUM GAS-SUPPLY PRESSURE REQUIREMENTS***

Gas Type| Min. Manifold Pressure| Min. Gas-Supply Pressure**
Natural| 5” water column| 6” water column
LP (propane)| 10” water column| 11”water column
*Gas-supply pressure for testing the regulator setting shall be at least 1”water column (249 Pa) above the specified manifold pressure; **Max gas-supply pressure, all models: 1/2psi.
The above ratings are for reference only; see the rating label (upper-reroof range) for exact specifications.

Critical Depth/Height Dimensions

GAS-/ELECTRICAL-ACCESS DIMENSIONS

Model| A| B| C| D| E**
HDPR30S/ HDER30S| 3 1/4″ (8.3 cm)| 27”

(68.6 cm)

| 6 3/4″ (17.1cm)| 6 3/4 (17.1cm)| 7/8”

(2.2 cm)

dia.

HDPR36S/ HDER36S| 6 3/4″ (17.1cm)| 27”

(68.6 cm)

| 12”

(30.5 cm)

HDPR48S/ HDER48S| 4 1/4” (10.8 cm)| 27”

(68.6 cm)

| 9”

(22.9 cm)

*Measurement with range legs adjusted to their lowest height; **the hole size for the electrical wiring may be increased to 11/8”(2.9 cm) by removing the conduit bracket in the bottom of the electrical box.

Cabinet Layout

  • All maximum/minimum dimensions and clearances in the diagrams below must be maintained for safe operation.
  • Place the range away from drafts (open doors and windows ,and home heating/cooling systems).
  • Do not install cabinets over the range, or to reduce risk of burn injury from reaching over a hot cooktop, install a range hood that projects horizontally at least 5” beyond the cabinet bottoms.
  • The range may be installed against the rear wall. Dacor strongly recommends installing a blackguard or non-combustible material on the rear wall between the range vent hood.
  • Seal openings the wall behind the range and in the floor below.
  • The grey area in the diagram below shows the suggested gas/ electrical utilities. Existing utilities may be used if they do not hinder range placement.
  • Gas/electrical utilities must be located so the range can be moved for service without being disconnected.
  • An external, manual shut-off valve must be installed between the gas inlet and range so gas to the range can be shut on/off.
  • Installation must allow access to the gas shut-off valve and circuit-breaker panel/fuse box when the range is in place.

CUTOUTDIMENSIONS

Model| F: recommended/min.| G: min./max.| H
HDPRS/HDERS 30| 36”(91.4 cm) / 30” (76.2cm)| 30” (76.2 cm) / 30 1/8”(76.5cm)| 273/8″(69.5 cm)
HDPRS/HDERS 36| 42” (106.7 cm) / 36”(91.4cm)| 36”(91.4 cm) / 36 1/8”(91.8cm)| 33 1/2”(84.8 cm)
HDPRS/HDERS 48| 54”(137.2cm) / 48” (122.0cm)| 48” (121.9cm) / 48 1/8”(122.2 cm)| 43 1/2”(110.5cm)

Standard Cutout with Range Hood

Standard Cutout with Range Hood

APPROVED DOWNDRAFTVENTS

Range| Downdraft Vent
HDPRS/HDERS 30| MRV3015
HDPRS/HDERS 36| MRV36-ER
HDPRS/HDERS 48| MRV48-ER
IMPORTANT: See downdraft installation instructions for duct and electrical installation require- mints. Use only approved Dacor down draft vents.

Standard Cutout with Range Hood

Countertop Cutout For Downdraft Vent

  1. Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood specifications for minimum required clearances.
  2. Cabinet/countertop depth is at customer discretion, but cabinet face must not protrude beyond reroof range front panel. (See Pg.1fordimensions.)
  3. Consult local codes for exact location requirements.
  4. Vertical from grate level to combustible surface.
  5. Not applicable to cabinets that horizontally are over10” (25.4 cm) from range edge.

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals