dacor HGPR48S Heritage 36 48 Wide Gas Pro Range User Guide
- June 17, 2024
- dacor
Table of Contents
**dacor HGPR48S Heritage 36 48 Wide Gas Pro Range User Guide
**
WARNING
- Observe all governing codes and ordinances during planning and installation. Contact your local building department for details.t
- The range must be installed as specified in its installation instructions.
WIDTHS
HGPR36S 35 7/8” (91.1 cm)
HGPR48S 47 7/8” (121.6 cm)
Range | Downdraft Vent |
---|---|
HGPR36S | MRV36-ER |
HGPR48S | MRV48-ER |
Range | 1.5” Low-Profile Backguard |
HGPR36S | APB36GLP |
HGPR48S | APB48GLP |
WARNING
- Observe all governing codes and ordinances during planning/ installation. Contact your local building department for details.
- To prevent electric shock, the power supply must meet the specifications stated below. The owner shall ensure the electrical service meets requirements and that the outlet is properly installed/ inspected by a licensed electrician.
The range must be electrically grounded according to local codes or, in their absence, with the National Electrical Code, ANSI/ NFPA 70.
Electrical Requirements
- The range is supplied with a factory installed, 6-ft. long power cord with a 3-prong grounding plug. It is connected to the chassis at the rear of the range. It must be connected to a dedicated, grounded 3-prong electrical outlet.
- The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse.
Model | Circuit Required | Total Connected **Load*** |
---|---|---|
HGPR36S | 120 Vac, 60 Hz, 15 Amp. | 120 Vac 60 Hz, 5.0 Amp. |
HGPR48S | 120 Vac, 60 Hz, 15 Amp. | 120 Vac 60 Hz, 8.0 Amp. |
*These figures are for reference only. See the rating label for exact specifications.
Gas-Supply Requirements
- Installation of this range must conform to local codes or, in their absence, to the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- The range being installed must match the home gas service (natural or LP gas).
- If using the range above 4000 ft. (1219 m) altitude, ensure it is equipped for high-altitude use. See the rating label and graphic on the inside front cover to verify the correct model.
- This table has gas-supply pressure requirements:
GAS-SUPPLY PRESSURE **REQUIREMENTS***
Gas Type| Min. Manifold Pressure| Minimum Gas-Supply
Pressure**
Natural Gas| 5” Water Column| 6” Water Column
Liquid Propane (LP)| 10” Water Column| 11” Water Column
*The gas-supply pressure for testing the regulator setting shall be at least 1” water column (249 Pa) above the specified manifold pressure’; **max. gas supply pressure for all models: 1/2 psi; the ratings above are for reference only. See the rating label for exact specifications.
- Use only the factory-installed regulator. The regulator inlet receives a 3/4” gas line. The range ships with a 1/2”-to-3/4” adapter connected to the regulator.
GAS-/ELECTRICAL-ACCESS DIMENSIONS
Model| A| B
HGPR36S| 13 ¹/₁₆” to 14 3/8” (33.2 to 36.5 cm)| 7 ⁵/₁₆” (18.6 cm)
HGPR48S| 13 ¹/₁₆” to 14 3/8” (33.2 to 36.5 cm)| 4 1/4” (10.8 cm)
Cabinet Layout
- For safe operation, maintain all specified maximum/minimum dimensions and clearances.
- Install the range away from drafts (open doors/windows, home ventilation).
- Do not install cabinets directly above the range, or reduce risk of fire and injury (from reaching over an active cooktop) by installing a range hood that projects horizontally at least 5” beyond the cabinet bottom.
- You may place the range against the rear wall. Dacor recommends installing non-combustible material on the wall between the range and vent hood. Non-combustible material directly behind the range is not needed, but seal any openings in the wall behind the range and in the floor beneath it.
Gas and Electrical Service
-
Locate the gas inlet and electrical outlet in an adjacent cabinet (see the cabinet graphic). If replacing the range, existing utilities may be used if they do not impede the new range’s placement.
Check building codes for permissible gas-valve locations. -
An external, manual shut-off valve must be installed between the gas inlet and range so gas to the range can be turned on/off.
-
Location of the gas-supply piping and shut-off valve, and the electrical outlet must not interfere with placement of the range.
-
The gas valve and electrical outlet must be accessible without moving the range.
-
Install the gas shut-off valve so the range can be pulled out for service/cleaning without disconnecting the conduit.
Callout | Description |
---|---|
1 | Grate top to combustible overhead surface. NOTE: If installing a vent hood, |
check hood specifications for minimum required clearances.
2| Cabinet face must NOT extend beyond rear of front panel (see Product
Dimensions, Pg. 1).
3| Consult local code for exact location requirements.
4| Vertical from top of grate to combustible surface.
5| Does not apply for cabinets more than a horizontal distance of 10” (25.4
cm) from edge of range.
Cutout For Optional Downdraft Vent
CUTOUT DIMENSIONS
Model| F—recommended/ min| G—min/ max| H
HGPR36| 42” (106.7 cm)/36” (91.4 cm)| 36” (91.4 cm)/36 1/8” (91.8 cm)| 33 1/2”
(84.8 cm)
HGPR48| 54” (137.2 cm)/48” (122.0 cm)| 48” (121.9 cm)/48 1/8” (122.2 cm)| 43
1/2” (110.5 cm)
All specifications subject to change without notice. www.dacor.com Ph. 800.793.0093