EMOS VT-120 Voltage Tester User Manual

June 17, 2024
EMOS

EMOS VT-120 Voltage Tester

EMOS-VT-120-Voltage-Tester-FIG-1

Product Information

Specifications

  • Product Name: Voltage Tester VT-120
  • Battery Type: GP A76, GP 303, GP 357, GP S 76 E
  • Battery Life: Minimum 5 hours of continuity operation

Product Usage Instructions

Batteries Replacement

  1. Lift up the clip and push it out.
  2. Replace the batteries.
  3. Put on the clip and push it back.

Operation Guide

Self-test
Prior to use, please perform a Self-test to ensure guaranteed Indication:

  1. Turn the switch to the “O” position.
  2. Touch the Driven Blade with one hand and touch the upper contact with the other hand.
  3. The red LED should light up, indicating normal function.

Microwave Leakage Detection

  1. Turn the switch to the “L” position.
  2. Move the Driven Blade of the tester slowly over and around the microwave oven, TV screen, or PC monitor.
  3. If microwave leakage is detected, the green LED will light up, and a beep sound will be heard.

Verification of Wire Connection

  1. Turn the switch to the “L” position.
  2. Move the Driven Blade of the tester slowly over the tested wire.
  3. If voltage is detected, the green LED will light up, and a beep sound will be heard.
  4. If the wire is broken, the green LED and beep will turn off.
    Note: Do not dispose of the product with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices are disposed of in a landfill, dangerous substances may reach groundwater and subsequently the food chain, where they could affect human health.
    EMOS spol s.r.o. declares that the VT-120 is in compliance with the essential requirements and other relevant provisions of the Directive. The device can be freely operated in the EU. The Declaration of Conformity can be found at http://www.emos.eu/download.

Frequently Asked Questions (FAQ)

  • What type of batteries does the VT-120 use?
    The VT-120 uses GP A76, GP 303, GP 357, and GP S 76 E batteries.

  • What is the battery life of the VT-120?
    The battery life of the VT-120 is a minimum of 5 hours of continuity operation.

  • How do I replace the batteries?
    To replace the batteries:

    1. Lift up the clip and push it out.
2. Replace the batteries.
3. Put on the clip and push it back.
  • How do I perform a self-test?
    To perform a self-test:

    1. Turn the switch to the “O” position.
2. Touch the Driven Blade with one hand and touch the upper contact with the other hand.
3. The red LED should light up, indicating normal function.
  • How do I detect microwave leakage?
    To detect microwave leakage:

    1. Turn the switch to the “L” position.
2. Move the Driven Blade of the tester slowly over and around the microwave oven, TV screen, or PC monitor.
3. If microwave leakage is detected, the green LED will light up, and a beep sound will be heard.
  • How do I verify wire connections?
    To verify wire connections:

    1. Turn the switch to the “L” position.
2. Move the Driven Blade of the tester slowly over the tested wire.
3. If voltage is detected, the green LED will light up, and a beep sound will be heard.
4. If the wire is broken, the green LED and beep will turn off.
  • How should I dispose of the VT-120?
    Do not dispose of the VT-120 with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices are disposed of in a landfill, dangerous substances may reach groundwater and subsequently the food chain, where they could affect human health.

  • Is the VT-120 compliant with regulations in the EU?
    Yes, EMOS spol s.r.o. declares that the VT-120 is in compliancewith the essential requirements and other relevant provisions of the Directive. The device can be freely operated in the EU.

New Invention and Safety Tester VT-120. It allows you to check/test with safety, quickly and accurately many electrical features.
Read carefully the user manual before use.

Tested features

  • AC voltage test: Non-contact method from 70–250 V AC
  • DC voltage test: Up to 250 V DC
  • Polarity test: 1.2 V – 36 V DC
  • Continuity check: O = 0–5 MΩ, L = 0–50 MΩ, H = 0–100 MΩ
  • Microwave leakage detection: > 5 mW/cm2

BATTERIES REPLACEMENT

  1. Lift up the clip and push it out.
  2. Replace the batteries.
  3. Put on the clip and push it back.

Suitable batteries
type: GP A76, GP 303, GP 357, GP S 76 E; Battery life: Min. 5 hours of continuity operation.

OPERATION GUIDE

Self-test
Prior to use, please perform a Self-test to ensure guaranteed Indication. Turn the switch to “O” position. Touch the Driven Blade and other hand touch the upper contact. Red LED lights up indicating normal function.

Microwave leakage detection
Turn the switch to “L” position. Move the Driven Blade of the tester slowly over and around the microwave oven, TV screen or PC monitor. The green LED lights up and beep sounds, if microwave leakage is detected.

Testing AC Voltage – non-contact method
Turn the switch to “L” position. Hold the tester and touch the upper contact. To locate “Live/Hot” side of wire, gently trace the tester along the wire. Live/Hot side is indicated by the green LED and beep sound.

Determination of Polarity – Contact Method
The tester can be used to determine voltage polarity within voltage range of 1.2–36V. Touch one of the poles of the power source with your hand and the other pole with the tester tip. Touch the metal sensor on the side of the tester with a finger of the hand holding the tester. If a green indicator lights up, the tester tip is touching the positive pole.

Verification of wire connection
Turn the switch to “L” position. Move the Driven Blade of the tester slowly over tested wire. Voltage is detected by the green LED and beep sound. Where the wire is broken, the green LED and beep turn off.

  • Electronic Component Check – contact method (Turn the switch to “O” position)
  • Bulb – Hold the bulb socket. Touch the bottom contact of bulb with the tester and touch the upper contact of the tester with your finger. The bulb is functional, if the green LED lights up.
  • Fuse – Process is the same as Bulb.
  • Coils and resistors – Process is the same as Bulb.
  • Diodes – Process is the same as Bulb. The red LED lights up in conducting direction and doesn’t light in reverse direction.
  • Capacitor – Process is the same as Bulb. If the capacitor is OK, the red LED lights up and slowly go down.
  • Transistors: PNP – Touch the emitter or collector. Then touch the base with the tester. The red LED lights up, if the transistor works correctly.
  • Transistors: NPN – Touch the base. Then touch the emitter or collector with the tester. The red LED lights up, if the transistor works correctly.

CAUTION

  • Never use the tester without the upper cap
  • Never test the voltage with contact method, if you don’t know exactly its range.
  • You can test only the voltage range, which is safe for current environment
  • Handle the tester according the valid standard

DISPOSAL

  • This product is not to be used by persons (including children), whose physical, sensual or mental abilities or lack of experience and knowledge does not ensure safe use of the appliance, unless they are supervised or unless they have been instructed about the use of this appliance by a person in charge of their safety. Supervision over children is required to prohibit them from playing with the appliance.
  • Do not dispose with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices would be disposed on landfill, dangerous substances may reach groundwater and subsequently food chain, where it could affect human health.
  • EMOS spol s.r.o. declares that the VT-120 is in compliance with the essential requirements and other relevant provisions of Directive. The device can be freely operated in the EU. The Declaration of Conformity can be found at http://www.emos.eu/download.