EMOS P5682 Capillary Sensor Thermostat Instruction Manual

June 3, 2024
EMOS

P5682
Capillary Sensor Thermostat

Operating Instructions and Installation

Description

  • Capillary Sensor Thermostat with a visible external scale.
  • Easy to operate thanks to the large manual dial.
  • Temperature range 0 °C – 90 °C (tolerance 5 °C).
  • Easy electrical connection thanks to the sufficiently large cable clamps.

Installation

  1. Thermostat to be mounted to the pipe’s surface, attach to any place and secure the external sensor on the surface of the system designated for the water transfer, where the temperature is supposed to be measured. Observe the direct and safe contact with the surface. (Any insulation must be removed from the spot where the sensor is going to be mounted.)
  2. The Capillary pipe located between the thermostat and the external sensor must not be curved (bent) in any case!

Electric Connection

EMOS P5682 Capillary Sensor Thermostat-

  1. Open the thermostat by pulling out the dial (1) and then release the large plastic screw (2).

  2. Remove the lid from the case. Now you see the four plastic clamps, these must be connected in the following way:
    • Clamp C and 1 = opener

  3. The thermostat will be opened as the temperature is increasing and will be closed as the temperature decreases (E. g. function = „Heating“).
    • Clamp C and 2 = opener

  4. The thermostat will be closed as the temperature is increasing and will be opened as the temperature is decreasing (E. g. function = „Cooling“).
    • Clamp = Grounding

The installation may be done by the professional heating technician only and in the accordance with the connection plan. Moreover, the installation must comply the currently valid regulations and must comply as well as the specifications issued by your energy supplier. The installation must always be done when the electricity supply is switched off. All the safety specifications must be observed. Observe the maximum switching current stated in the technical specifications!

Technical Specifications

Operating Voltage: 230 V AC 50 Hz, 400 V AC 50 Hz
Contact: 1 two-way contact
Switching Current: 16 (4) A – 230 V, 6 (1) A – 400 V
Temperature Controlling Range: 0 °C – 90 °C
Sensor Unit: liquid sensor
Coverage: IP40
Do not dispose with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices would be disposedon landfill, dangerous substances may reach groundwater and subsequently food chain, where it could affect human health.

www.emos.eu

Documents / Resources

| EMOS P5682 Capillary Sensor Thermostat [pdf] Instruction Manual
P5682 Capillary Sensor Thermostat, P5682, P5682 Sensor Thermostat, Capillary Sensor Thermostat, Sensor Thermostat, Capillary Thermostat, Capillary Sensor
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals