GENERAL AOHG09KBTB Air Conditioner Instruction Manual
- June 17, 2024
- GENERAL
Table of Contents
GENERAL AOHG09KBTB Air Conditioner
Product Information
Specifications
- Model: AOHG09KBTB (Outdoor Unit), AUXG09KVLA (Indoor Unit), ARXG09KLLAP (Indoor Unit)
- Type: Cassette and Duct
- Max. Pressure: High / Discharge – (4.20) bar(MPa), Low / Suction – (2.76) bar(MPa)
- Manufacturing Date: Refer to the rating label
- Power Resource: 230 V ~ 50 Hz
- Cooling Capacity: 2.50 kW – 4.30 kW
- Heating Capacity: 3.20 kW – 5.00 kW
- Power Input: 0.55 kW – 1.32 kW
- Current: 2.9 A – 10.2 A
- Max. Current: 7.9 A – 10.2 A
- Energy Efficiency Ratio: 3.36 kW/kW – 4.57 kW/kW
- Weight: Outdoor Unit – 32 kg, Indoor Unit (Grille) – 15 kg (2.3 kg)
- Refrigerant Charge (Tons – CO2 equivalent): 0.85 kg (0.574 t-CO2eq)
Product Usage Instructions
Installation
To install the air conditioner, follow the steps below:
- Choose a suitable location for the outdoor unit.
- Mount the outdoor unit securely on a stable surface.
- Connect the indoor unit to the outdoor unit using the provided cables and pipes.
- Position the indoor unit in the desired location.
- Ensure all connections are properly tightened and insulated.
Operation
To operate the air conditioner, use the following steps:
- Make sure the power supply is connected and turned on.
- Set the desired temperature using the remote control or control panel.
- Select the appropriate mode (cooling, heating, or dry) based on your needs.
- Adjust the fan speed and direction as desired.
- Monitor the temperature and adjust settings as needed to maintain comfort.
Maintenance
To keep the air conditioner in optimal condition, perform regular maintenance tasks:
- Clean or replace the air filters regularly to ensure proper airflow.
- Clean the indoor and outdoor units to remove dust and debris.
- Inspect and clean the condenser coil to improve efficiency.
- Check for any leaks or damage in the refrigerant lines.
- Schedule professional maintenance at least once a year.
FAQ
- Q: How often should I clean the air filters?
- A: It is recommended to clean or replace the air filters every 2-4 weeks, depending on usage and air quality.
- Q: Can I use the air conditioner in humid conditions?
- A: Yes, the air conditioner can be used in humidity levels up to 80%.
- Q: What is the operating temperature range for cooling and heating?
- A: The air conditioner can cool in temperatures between 18°C and 32°C and heat in temperatures between 16°C and 30°C.
PRODUCT FICHE
KEEP THIS MANUAL FOR FUTURE REFERENCE
- Product fiche according to Commission Delegated Regulation (EU) 626/2011
MODEL
| OUTDOOR UNIT| AOHG09KBTB| AOHG12KBTB| AOHG14KBTB
---|---|---|---|---
INDOOR UNIT| AUXG09KVLA| ARXG09KLLAP| AUXG12KVLA| ARXG12KLLAP| ARXG12KHTAP|
AUXG14KVLA| ARXG14KLLAP| ARXG14KHTAP
| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING|
COOLING| HEATING| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING
SOUND POWER LEVEL| OUTDOOR UNIT
[dB(A)]| 59| 59| 59| 59| 61| 61| 61| 61| 61| 61| 62| 62| 62| 62| 62| 62
INDOOR UNIT [dB(A)]| 46| 47| 57| 57|
49| 49| 58| 58| 57| 58| 50| 55| 60| 60| 59| 60
REFRIGERANT/GLOBAL WARMING POTENTIAL| R32 / 675 (IPCC AR4) (*1)
SEASONAL ENERGY EFFICIENCY RATIO/ SEASONAL COEFFICIENT OF PERFORMANCE|
6.7
|
4.4
|
6.2
|
4.3
|
6.6
|
4.3
|
6.1
|
4.0
|
6.3
|
4.1
|
6.5
|
4.4
|
5.8
|
3.9
|
6.2
|
4.0
ENERGY EFFICIENCY CLASS| A++| A+| A++| A+| A++| A+| A++| A+| A++| A+| A++| A+|
A+| A| A++| A+
ANNUAL ENERGY CONSUMPTION
[kWh/a] (QCE)(QHE)|
131 (*2)
|
826 (*3)
|
141 (*2)
|
845 (*3)
|
186 (*2)
|
1106 (*3)
|
201 (*2)
|
1189 (*3)
|
194 (*2)
|
1159 (*3)
|
231 (*2)
|
1208 (*3)
|
259 (*2)
|
1362 (*3)
|
243 (*2)
|
1328 (*3)
Pdesign [kW]| 2.5
(35 °C)
| 2.6
(-10 °C)
| 2.5
(35 °C)
| 2.6
(-10 °C)
| 3.5
(35 °C)
| 3.4
(-10 °C)
| 3.5
(35 °C)
| 3.4
(-10 °C)
| 3.5
(35 °C)
| 3.4
(-10 °C)
| 4.3
(35 °C)
| 3.8
(-10 °C)
| 4.3
(35 °C)
| 3.8
(-10 °C)
| 4.3
(35 °C)
| 3.8
(-10 °C)
BACKUP HEATER CAPACITY/ [kW] DECLARED CAPACITY|
―
| 0.53/
2.08
|
―
| 0.50/
2.11
|
―
| 0.60/
2.80
|
―
| 0.58/
2.82
|
―
| 0.60/
2.80
|
―
| 0.56/
3.24
|
―
| 0.59/
3.21
|
―
| 0.54/
3.26
NOTES
- Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this refrigerant fluid were leaked into the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO2, for 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
- Energy consumption “QCE” kWh per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
- Energy consumption “QHE” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Specifications
MODEL
| OUTDOOR UNIT| AOHG09KBTB| AOHG12KBTB| AOHG14KBTB
---|---|---|---|---
INDOOR UNIT| AUXG09KVLA| ARXG09KLLAP| AUXG12KVLA| ARXG12KLLAP| ARXG12KHTAP|
AUXG14KVLA| ARXG14KLLAP| ARXG14KHTAP
TYPE
| CASSETTE| DUCT| CASSETTE| DUCT| CASSETTE| DUCT
SINGLE SPLIT / HEAT PUMP
MAX. PRESSURE| HIGH / DISCHARGE [bar(MPa)]| – (4.20)
LOW / SUCTION| [bar(MPa)]| – (2.76)
MANUFACTURING DATE| Refer to the rating label
POWER RESOURCE| 1φ 230 V ~ 50 Hz
| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING|
COOLING| HEATING| COOLING| HEATING| COOLING| HEATING| COOLING| HEATING
CAPACITY| [kW]| 2.50| 3.20| 2.50| 3.20| 3.50| 4.10| 3.50| 4.10| 3.50| 4.10|
4.30| 5.00| 4.30| 5.00| 4.30| 5.00
POWER INPUT| [kW]| 0.55| 0.79| 0.60| 0.79| 0.93| 1.08| 0.93| 1.08| 0.87| 1.00|
1.28| 1.32| 1.28| 1.32| 1.17| 1.25
CURRENT| [A]| 2.9| 4.0| 3.1| 4.0| 4.1| 4.8| 4.1| 4.8| 3.9| 4.4| 5.6| 5.8| 5.6|
5.8| 5.1| 5.5
MAX. CURRENT| [A]| 7.9| 7.9| 7.9| 7.9| 9.7| 9.7| 9.7| 9.7| 9.7| 9.7| 10.2|
10.2| 10.2| 10.2| 10.2| 10.2
ENERGY EFFICIENCY RATIO/ COEFFICIENT OF PERFORMANCE| [kW/kW]| ****
4.57
| ****
4.05
| ****
4.17
| ****
4.05
| ****
3.76
| ****
3.80
| ****
3.76
| ****
3.80
| ****
4.02
| ****
4.10
| ****
3.36
| ****
3.79
| ****
3.36
| ****
3.79
| ****
3.68
| ****
4.00
DIMENSION (H×W×D)
| OUTDOOR UNIT| [mm]| 542 × 799 × 290
INDOOR UNIT (GRILLE)| **** [mm]| 245 × 570 × 570
(49 × 620 × 620)
| 198 × 700 × 620| 245 × 570 × 570
(49 × 620 × 620)
| 198 × 700 × 620| 300 × 700 × 700| 245 × 570 × 570
(49 × 620 × 620)
| 198 × 700 × 620| 300 × 700 × 700
WEIGHT
| OUTDOOR UNIT| [kg]| 32| 33| 33
INDOOR UNIT (GRILLE)| [kg]| 15
(2.3)
| 17| 15
(2.3)
| 17| 27| 15
(2.3)
| 17| 27
REFRIGERANT CHARGE
(Tons – CO2 equivalent)
| [kg]
(t-CO2eq)
| 0.85
(0.574)
- For more information, visit our website at: www.fujitsu-general.com.
- For spare parts inquiries, consult the store where you purchased the product.
- Sound pressure level: less than 70 dB(A) according to IEC 704-1.
OPERATING RANGE | INDOOR | OUTDOOR |
---|---|---|
COOLING/DRY [°C] | 18 | |
to 32 | -15 to 46 |
HEATING
[°C]| 16 to 30| -15 to 24
HUMIDITY [%]|
80 or less| ―
- If the air conditioner is operated under the conditions except the permissible temperature range, the air conditioner may stop because of the automatic protection circuit working.
- Depending on the operating conditions, the heat exchanger may freeze during the Cooling or Dry mode and it may cause water leakage and other damage.
- If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath.
CONTACT
- FUJITSU GENERAL LIMITED
- 3-3-17, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan.
- www.fujitsu-general.com.